Illustration 1 g01066487
Schematic for the # 2 Lower Solenoid This diagnostic code is associated with the solenoid valve (No. 2) (lower). The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes for this diagnostic code are listed:
The signal circuit from the ECM to the solenoid is shorted to the +battery.
The return circuit from the solenoid is shorted to the +battery.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0593 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The machine response is listed:All implement functions will be disabled.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-8 (wire F742-PU) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-8 (wire F742-PU) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0593 FMI 03 is active.Expected Result:The CID 0593 FMI 03 is active.Results:
YES - The CID 0593 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 0593 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. Stop.
Caterpillar parts catalog:
Parts guard Caterpillar catalog:
2P5916
GUARD
D9H
D9H
9K0441
GUARD
814
814
5M0907
GUARD
D8H
D8H
9K7919
GUARD ASSEM.
814, 815
814, 815
9K6594
GUARD ASSEM.
826B
826B
8K9681
GUARD ASSEM.
826B
826B
1P3793
GUARD ASSEM. (R.H.)
D7F, D8H
D7F, D8H
1P3794
GUARD ASSEM. (L.H.)
D7F, D8H
D7F, D8H