2582533 HANDLE Caterpillar parts
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 246C, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267, 267B, 268B, 272C, 277C, 277C2, 279C, 279C...
Rating:
Alternative (cross code) number:
CA2582533
258-2533
2582533
CA2582533
258-2533
2582533
Weight: 3 pounds 1 kg.
COMPACT TRACK LOADER, SKID STEER LOADER,
This part in 4 request:
Show.
This information for suppliers only!
2024-05-20
2022-07-12
2021-05-10
2021-01-12
Compatible equipment models: 2582533:
Information:
The preceding diagram is a simplified schematic of the connections for the sensor supply circuits. The schematic is electrically correct. However, not all the possible harness connectors are shown. Refer to the latest revision of the applicable electrical schematic to view the entire circuitry of the machine.Diagnostic Trouble Code Procedure
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Identify the active FMI code associated with the components.
Determine which code is present and use the list below to determine which procedure to follow.
FMI 3 diagnostic code, proceed to Table 2.
FMI 4 diagnostic code, proceed to Table 3.
Table 2
FMI 3 Troubleshooting
Troubleshooting Test Steps Values Results
1. Check The Voltage At The Sensors
A. Turn key start switch and disconnect switch ON.
B. Disconnect the machine harness connector for the sensors.
C. At the machine harness connector for the sensors, measure the voltage between the sensor supply contact and the sensor return contact.
Voltage reading is correct for the sensors. OK - The voltage reading is correct for the sensors.
Proceed to Test Step 4.
NOT OK - The voltage is greater than the supply for the circuit.
Proceed to Test Step 2.
2. Check The Power Supply At The ECM
A. Turn the key start switch and disconnect switch to the OFF position.
B. At the J1 harness connector for the ECM, use a 151-6320 Removal Tool to remove the supply wire and the sensor return wire. The harness connector remains connected to the ECM.
C. Turn the disconnect switch and the key start switch to the ON position.
D. Use the multimeter probes to make contact on the connector pins. Measure the voltage at the ECM pins between the sensor supply contact and sensor return contact .
Voltage reading is correct for the supply. OK - The voltage is correct. The ECM power supply is correct. Install the wires and sockets that were removed from the ECM connector back into the original locations.
Proceed to Test Step 3.
NOT OK - The voltage measurement is greater than the supply voltage. The measurement is not correct. The ECM may have failed.
Proceed to Test Step 4.
3. Check For A Short In the Harness
A. The sensors remain disconnected from the machine harness.
B. The key start switch and disconnect switch remainOFF.
C. Disconnect the machine harness connectors from the ECM.
D. At the ECM harness connector, measure the resistance between the supply contact and all the other contacts that are used for the ECM.
Each resistance is greater than 5K Ω. OK - Each resistance is greater than 5K Ω.
Proceed to Test Step 4.
NOT OK - One or more readings less than 5 Ω. There is
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Identify the active FMI code associated with the components.
Determine which code is present and use the list below to determine which procedure to follow.
FMI 3 diagnostic code, proceed to Table 2.
FMI 4 diagnostic code, proceed to Table 3.
Table 2
FMI 3 Troubleshooting
Troubleshooting Test Steps Values Results
1. Check The Voltage At The Sensors
A. Turn key start switch and disconnect switch ON.
B. Disconnect the machine harness connector for the sensors.
C. At the machine harness connector for the sensors, measure the voltage between the sensor supply contact and the sensor return contact.
Voltage reading is correct for the sensors. OK - The voltage reading is correct for the sensors.
Proceed to Test Step 4.
NOT OK - The voltage is greater than the supply for the circuit.
Proceed to Test Step 2.
2. Check The Power Supply At The ECM
A. Turn the key start switch and disconnect switch to the OFF position.
B. At the J1 harness connector for the ECM, use a 151-6320 Removal Tool to remove the supply wire and the sensor return wire. The harness connector remains connected to the ECM.
C. Turn the disconnect switch and the key start switch to the ON position.
D. Use the multimeter probes to make contact on the connector pins. Measure the voltage at the ECM pins between the sensor supply contact and sensor return contact .
Voltage reading is correct for the supply. OK - The voltage is correct. The ECM power supply is correct. Install the wires and sockets that were removed from the ECM connector back into the original locations.
Proceed to Test Step 3.
NOT OK - The voltage measurement is greater than the supply voltage. The measurement is not correct. The ECM may have failed.
Proceed to Test Step 4.
3. Check For A Short In the Harness
A. The sensors remain disconnected from the machine harness.
B. The key start switch and disconnect switch remainOFF.
C. Disconnect the machine harness connectors from the ECM.
D. At the ECM harness connector, measure the resistance between the supply contact and all the other contacts that are used for the ECM.
Each resistance is greater than 5K Ω. OK - Each resistance is greater than 5K Ω.
Proceed to Test Step 4.
NOT OK - One or more readings less than 5 Ω. There is
Cat SIS web machinery list:
Parts handle Caterpillar catalog:
2521862
HANDLE AS
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D ...
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D ...
2233725
HANDLE GP-MODULAR
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 267B
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 267B
2233726
HANDLE GP-MODULAR
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 268B
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 268B
2186377
HANDLE
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 268B
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 268B
2843914
HANDLE
216B, 226B, 232B, 236B, 236D, 242B, 242D, 246C, 247B, 252B, 256C, 257B, 257D, 259D, 262C, 262C2, 262D, 267B, 268B, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, ...
216B, 226B, 232B, 236B, 236D, 242B, 242D, 246C, 247B, 252B, 256C, 257B, 257D, 259D, 262C, 262C2, 262D, 267B, 268B, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, ...
2186433
HANDLE
246C, 256C, 262C, 262C2, 272C, 272D, 272D XHP, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D, 299D XHP
246C, 256C, 262C, 262C2, 272C, 272D, 272D XHP, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D, 299D XHP
2583288
HANDLE AS
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
2583294
HANDLE AS
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
246C, 256C, 262C, 272C, 277C, 279C, 287C, 289C, 297C, 299C
2584076
HANDLE AS
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
3641821
HANDLE AS
236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
3641822
HANDLE AS
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
2584018
HANDLE
246C, 256C, 262C, 262C2, 272C, 272D, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D
246C, 256C, 262C, 262C2, 272C, 272D, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 299D
1428787
HANDLE
216, 228, 236, 248, 267
216, 228, 236, 248, 267
1428786
HANDLE
216, 228, 236, 248, 267
216, 228, 236, 248, 267
1953510
HANDLE-CONTROL
216, 236, 247, 267, 287, 301.5, 302.5, 420D, 430D, 432D, 442D, 446D, 953C, 963B, 963C, 973, 973C
216, 236, 247, 267, 287, 301.5, 302.5, 420D, 430D, 432D, 442D, 446D, 953C, 963B, 963C, 973, 973C
1138224
HANDLE
216, 236, 963B, 963C, 973, 973C
216, 236, 963B, 963C, 973, 973C
1429266
HANDLE
216, 236
216, 236
1678008
HANDLE
35, 45, 55
35, 45, 55
2482171
HANDLE AS
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 247, 247B, 247B3, 248, 252B, 252B3, 257B, 257B3, 259B3, 267, 267B, 268B, 287, 980H
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 247, 247B, 247B3, 248, 252B, 252B3, 257B, 257B3, 259B3, 267, 267B, 268B, 287, 980H
1429372
HANDLE
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
1417634
HANDLE AS
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
1595799
HANDLE
216, 228, 236, 247, 248, 267, 287
216, 228, 236, 247, 248, 267, 287
2213065
HANDLE GP-MODULAR
216, 228, 236, 247, 248, 267, 287, D8T
216, 228, 236, 247, 248, 267, 287, D8T
2582534
HANDLE
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 246C, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267, 267B, 268B, 272C, 277C, 277C2, 279C, 279C...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 242B, 242B3, 246C, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 259B3, 262C, 262C2, 267, 267B, 268B, 272C, 277C, 277C2, 279C, 279C...