Setting The Beeper
The display includes an internal beeper. The beeper can be configured to provide an audible signal when any of the events that are listed in Table 1 occur.
Table 1
Event    Sounds when...    
Above Grade     the cutting edge is more than one times the vertical tolerance and less than four times the vertical tolerance above grade.    
On Grade     the cutting edge is within the vertical tolerance of grade.    
Below Grade     the cutting edge is more than one times the vertical tolerance and less than four times the vertical tolerance below grade.    
Warning Messages     a warning message appears and when a warning message automatically disappears.    
GPS Accuracy     the GPS accuracy mode changes.    
Auto/Manual States     the guidance mode changes to Auto, Manual or Inactive Auto.    
Key/Switch Beeps     a key or a switch is pressed.    
Avoidance Zone     the machine is within the warning distance of an avoidance zone or if the "No Avoid" message is displayed. The beeper also sounds in a continuous pattern when the machine is within the avoidance zone. Avoidance zone beeper tones cannot be disabled.    Perform the following steps in order to access the "Beeper" dialog.
Illustration 1 g01300183
The AccuGrade System must be in Service Mode in order to access the beeper setup. From the "Setup Menu – Configuration" dialog, press the arrow keys until "Beeper" is highlighted.
Press the "OK" key. The "Beeper" dialog appears. This is shown in Illustration 2.Events that are disabled are identified by an "X" in the box. Events that are enabled are identified by a check mark. Events that cannot be disabled are identified by a grayed out check mark. Subevents that cannot be disabled independent of their master event are also identified by a grayed out check mark.
Illustration 2 g01300184
Press the arrow keys in order to select different events.
Press the first soft key on the right hand side of the display in order to enable or disable an event.The different events emit different beeper patterns. To hear the pattern for a particular event, press the "TEST" soft key when the event is selected.
Do one of the following.
Press the "OK" key in order to confirm the setting. The beeper setup is saved. The "Beeper" dialog is closed and the "Setup Menu – Configuration" dialog appears. The changes take effect immediately.
Press the "ESC" key and then press the "OK" key in order to return to the "Setup Menu – Configuration" dialog without saving the changes.
Press the "ESC" key in order to exit the "Setup Menu – Configuration" dialog.
The display includes an internal beeper. The beeper can be configured to provide an audible signal when any of the events that are listed in Table 1 occur.
Table 1
Event    Sounds when...    
Above Grade     the cutting edge is more than one times the vertical tolerance and less than four times the vertical tolerance above grade.    
On Grade     the cutting edge is within the vertical tolerance of grade.    
Below Grade     the cutting edge is more than one times the vertical tolerance and less than four times the vertical tolerance below grade.    
Warning Messages     a warning message appears and when a warning message automatically disappears.    
GPS Accuracy     the GPS accuracy mode changes.    
Auto/Manual States     the guidance mode changes to Auto, Manual or Inactive Auto.    
Key/Switch Beeps     a key or a switch is pressed.    
Avoidance Zone     the machine is within the warning distance of an avoidance zone or if the "No Avoid" message is displayed. The beeper also sounds in a continuous pattern when the machine is within the avoidance zone. Avoidance zone beeper tones cannot be disabled.    Perform the following steps in order to access the "Beeper" dialog.
Illustration 1 g01300183
The AccuGrade System must be in Service Mode in order to access the beeper setup. From the "Setup Menu – Configuration" dialog, press the arrow keys until "Beeper" is highlighted.
Press the "OK" key. The "Beeper" dialog appears. This is shown in Illustration 2.Events that are disabled are identified by an "X" in the box. Events that are enabled are identified by a check mark. Events that cannot be disabled are identified by a grayed out check mark. Subevents that cannot be disabled independent of their master event are also identified by a grayed out check mark.
Illustration 2 g01300184
Press the arrow keys in order to select different events.
Press the first soft key on the right hand side of the display in order to enable or disable an event.The different events emit different beeper patterns. To hear the pattern for a particular event, press the "TEST" soft key when the event is selected.
Do one of the following.
Press the "OK" key in order to confirm the setting. The beeper setup is saved. The "Beeper" dialog is closed and the "Setup Menu – Configuration" dialog appears. The changes take effect immediately.
Press the "ESC" key and then press the "OK" key in order to return to the "Setup Menu – Configuration" dialog without saving the changes.
Press the "ESC" key in order to exit the "Setup Menu – Configuration" dialog.
Caterpillar parts catalog:
Parts harness Caterpillar catalog:
1957336
HARNESS AS-ENGINE
120H, 135H, 3126B, 322C, 322C FM, 325C, 325C FM, 561N, 570B, 580B, 938G II, 950G II, 953C, 962G II, 963C, D5N, D6N, IT38G II, IT62G II, M325C MH, SPP101
120H, 135H, 3126B, 322C, 322C FM, 325C, 325C FM, 561N, 570B, 580B, 938G II, 950G II, 953C, 962G II, 963C, D5N, D6N, IT38G II, IT62G II, M325C MH, SPP101
2417879
HARNESS AS-FRONT CHASSIS
950G II, 962G II
950G II, 962G II
2113426
HARNESS AS-FRONT CHASSIS
950G II, 962G II
950G II, 962G II
2230789
HARNESS AS-FRONT CHASSIS
950G II, 962G II
950G II, 962G II
2768083
HARNESS AS-CHASSIS
950G II, 962G II, 980G II
950G II, 962G II, 980G II
2255859
HARNESS AS
950G II, 962G II
950G II, 962G II
2119443
HARNESS AS-SENSOR
950G II, 962G II
950G II, 962G II
1912914
HARNESS AS-SENSOR
950G II, 962G II
950G II, 962G II
2314912
HARNESS AS-WORK TOOL
950G II, 962G II
950G II, 962G II
2258826
HARNESS AS-SENSOR
962G II
962G II
2417881
HARNESS AS-QUICK COUPLER
950G II, 962G II, FUSION
950G II, 962G II, FUSION
1833896
HARNESS AS-SENSOR
950G II, 962G II
950G II, 962G II
2286088
HARNESS AS-OPERATOR CONTROLS
IT62G II
IT62G II
1974845
HARNESS AS-WIRING
950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT62G II
950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT62G II
1974840
HARNESS AS-LIGHTING
950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT62G II
950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT62G II
1956258
HARNESS AS-OPERATOR CONTROLS
950G II, 962G II, 966G II, 972G II, IT62G II
950G II, 962G II, 966G II, 972G II, IT62G II
2000837
HARNESS AS-SENSOR
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2000835
HARNESS AS-SENSOR
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2172997
HARNESS AS-FRONT CHASSIS
IT62G II
IT62G II
2248888
HARNESS AS-CONTROL
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2248889
HARNESS AS-SENSOR
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2016787
HARNESS AS-CONTROL
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2417878
HARNESS AS-CHASSIS
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II
2340620
HARNESS AS-CHASSIS
950G II, 962G II, IT62G II
950G II, 962G II, IT62G II