2242862 HARNESS AS-BOX Caterpillar parts
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
Rating:
Alternative (cross code) number:
CA2242862
224-2862
2242862
CA2242862
224-2862
2242862
Weight: 3 pounds 1 kg.
EXCAVATOR, MOBILE HYD POWER UNIT,
Compatible equipment models: 2242862:
Information:
"Machine Radio Configuration"
The "Machine Radio Configuration" utility allows you to change the network number or the frequency channel on Data Radios. The "Machine Radio Configuration" utility runs on the Display.To open the "Machine Radio Configuration" dialog, complete the following steps:
In Service mode, select the "Installation" Soft Key from the "Setup" menu.
Illustration 1 g01301490
Press the up arrow or the down arrow until "Machine Radio Configuration" is highlighted.
Press the "OK" key. The utility automatically attempts to connect to the radio.
Illustration 2 g01301489
Use the Arrow Keys (8) in order to select the same network as the base station for TC900C Radios. Use the Arrow Keys (8) to select the same frequency as the base station for TC450C Radios."Display's Radio Port"
When a third party radio is used, the Display for the AccuGrade System allows the user to adjust the following communication parameters:
Baud Rate
ParityThe "Display's Radio Port" settings sets the speed at which the Display communicates with the radio. These settings do not affect the speed of data transfer though the air between radios. Refer to the following Steps in order to adjust the "Display's Radio Port" settings.
Illustration 3 g01265962
(1) LCD (2) Soft Key Labels (3) Soft Keys (4) Escape Key (5 ) Next Key (6) Power Key (7) "+" Key (8) Arrow Keys (9) "-" Key (10) "OK" Key (11) Menu Key (12) "Data Card Slot"
To view all options in the "Setup Menu" dialog you must start the AccuGrade System in "Service" mode.Note: Hold the "OK" Key (10) while pressing the Power Key (6) in order to start the AccuGrade System in "Service" mode.
Press the Menu Key (11) until the Soft Key Label "Setup Menu" is shown. Press the Soft Key (3) beside the "Setup Menu" Soft Key Label.
Select the Soft Key that is located beside the "Installation" Soft Key Label from the "Setup" menu.
Illustration 4 g01288056
Press the up arrow or the down arrow until "Display's Radio Port" is highlighted.
Illustration 5 g01288144
Press the "OK" Key (10) .A screen that is similar to Illustration 5 will appear.
Press the up arrow or the down arrow in order to adjust the "Baud Rate". Press the Next Key (5) in order to toggle between the Display Radio Port fields
Press the up arrow or the down arrow in order to adjust the "Parity".
Press the "OK" Key (10) .
The "Machine Radio Configuration" utility allows you to change the network number or the frequency channel on Data Radios. The "Machine Radio Configuration" utility runs on the Display.To open the "Machine Radio Configuration" dialog, complete the following steps:
In Service mode, select the "Installation" Soft Key from the "Setup" menu.
Illustration 1 g01301490
Press the up arrow or the down arrow until "Machine Radio Configuration" is highlighted.
Press the "OK" key. The utility automatically attempts to connect to the radio.
Illustration 2 g01301489
Use the Arrow Keys (8) in order to select the same network as the base station for TC900C Radios. Use the Arrow Keys (8) to select the same frequency as the base station for TC450C Radios."Display's Radio Port"
When a third party radio is used, the Display for the AccuGrade System allows the user to adjust the following communication parameters:
Baud Rate
ParityThe "Display's Radio Port" settings sets the speed at which the Display communicates with the radio. These settings do not affect the speed of data transfer though the air between radios. Refer to the following Steps in order to adjust the "Display's Radio Port" settings.
Illustration 3 g01265962
(1) LCD (2) Soft Key Labels (3) Soft Keys (4) Escape Key (5 ) Next Key (6) Power Key (7) "+" Key (8) Arrow Keys (9) "-" Key (10) "OK" Key (11) Menu Key (12) "Data Card Slot"
To view all options in the "Setup Menu" dialog you must start the AccuGrade System in "Service" mode.Note: Hold the "OK" Key (10) while pressing the Power Key (6) in order to start the AccuGrade System in "Service" mode.
Press the Menu Key (11) until the Soft Key Label "Setup Menu" is shown. Press the Soft Key (3) beside the "Setup Menu" Soft Key Label.
Select the Soft Key that is located beside the "Installation" Soft Key Label from the "Setup" menu.
Illustration 4 g01288056
Press the up arrow or the down arrow until "Display's Radio Port" is highlighted.
Illustration 5 g01288144
Press the "OK" Key (10) .A screen that is similar to Illustration 5 will appear.
Press the up arrow or the down arrow in order to adjust the "Baud Rate". Press the Next Key (5) in order to toggle between the Display Radio Port fields
Press the up arrow or the down arrow in order to adjust the "Parity".
Press the "OK" Key (10) .
Caterpillar parts catalog:
Parts harness Caterpillar catalog:
3669313
HARNESS AS-SENSOR
311D LRR, 311F LRR, 312D, 312D L, 312D2, 314D CR, 314D LCR, 315D L, 318D2 L, 319D L, 319D LN, 320D, 320D L, 320D LN, 320D LRR, 320D RR, 321D LCR, 323D L, 323D LN, 323D SA, 324D, 324D L, 324D LN, 325D,...
311D LRR, 311F LRR, 312D, 312D L, 312D2, 314D CR, 314D LCR, 315D L, 318D2 L, 319D L, 319D LN, 320D, 320D L, 320D LN, 320D LRR, 320D RR, 321D LCR, 323D L, 323D LN, 323D SA, 324D, 324D L, 324D LN, 325D,...
2457821
HARNESS AS-HEATER & AIR COND
320D L, 323D L, 324D, 324D L, 324D LN, 325D, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 345C, 345...
320D L, 323D L, 324D, 324D L, 324D LN, 325D, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, 345C, 345...
3543234
HARNESS AS-WIRING
385C L MH
385C L MH
2836299
HARNESS AS-CHASSIS
385C L MH
385C L MH
3267820
HARNESS AS-SWITCH
385C L MH
385C L MH
2803269
HARNESS AS-CONSOLE
365C L MH, 385C L MH
365C L MH, 385C L MH
2803270
HARNESS AS-PANEL
365C L MH, 385C L MH
365C L MH, 385C L MH
3267271
HARNESS AS-CONTROL
385C L MH
385C L MH
2803267
HARNESS AS-CONSOLE
365C L MH, 385C L MH
365C L MH, 385C L MH
2815596
HARNESS AS-LIGHTING
365C L MH, 385C L MH
365C L MH, 385C L MH
2701233
HARNESS AS-SWITCH
365C L MH, 385C L MH
365C L MH, 385C L MH
2883664
HARNESS AS-LIGHTING
365C L MH
365C L MH
2510578
HARNESS AS-LIGHTING
365C, 365C L, 365C L MH, 374D L
365C, 365C L, 365C L MH, 374D L
2510520
HARNESS AS-CHASSIS
365C, 365C L, 365C L MH
365C, 365C L, 365C L MH
2510521
HARNESS AS-CHASSIS
365C, 365C L, 365C L MH
365C, 365C L, 365C L MH
2382420
HARNESS AS-PUMP
365C, 365C L, 365C L MH, 374D L, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L
365C, 365C L, 365C L MH, 374D L, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L
2341183
HARNESS AS-SENSOR
365C, 365C L, 365C L MH, 374D L
365C, 365C L, 365C L MH, 374D L
2311664
HARNESS AS-VALVE
365C, 365C L, 365C L MH
365C, 365C L, 365C L MH
2510601
HARNESS AS-CONSOLE
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
2595098
HARNESS AS-CONSOLE
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
2594968
HARNESS AS-CONTROL
365C, 365C L
365C, 365C L
2594967
HARNESS AS-CONTROL
365C, 365C L
365C, 365C L
3640306
HARNESS AS-CAB
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
365C, 365C L, 365C L MH, 385C, 385C FS, 385C L, 385C L MH
2500112
HARNESS AS-PLATFORM
365C, 365C L, 365C L MH
365C, 365C L, 365C L MH