Once the maximum fan speed is correct, press the "Next>" button in order to complete the test.
Illustration 8 g00925396
Typical example
The next screen will show that the test was successful. Select "Continue" in order to proceed.
If the test for the minimum fan speed was selected, proceed to "Calibration for Minimum Fan Speed". If the test for the minimum fan speed was not selected, disengage the throttle lock and stop the engine.
Remove the test equipment. Calibration for Minimum Fan Speed
Illustration 9 g00925407
Typical example
The next screen is the initial calibration screen. The screen displays the instructions for calibration. The top display area displays status parameters that are monitored during the calibration. The middle display area displays information about the status of the calibration. The display area on the bottom will display the conditions for the setup and the instructions for the calibration.
Illustration 10 g01286217
The display area will show the following conditions for the setup:
Set the parking brake.
Operate the engine at high idle. Use the throttle lock (4) in order to operate the engine at high idle.
Ensure that the hydraulic oil temperature exceeds 55 °C (131 °F).
Perform the following procedures in order to satisfy the conditions for setup.
Ensure that the parking brake is engaged.
Run the engine at high idle with the throttle lock.
Monitor the hydraulic oil temperature with the Cat ET screen and stall a hydraulic function in order to increase the hydraulic oil temperature. Stall a hydraulic function by moving the function to the end of travel.
When the conditions for setup are satisfied, press the "Next>" button in order to start the calibration. If the conditions for the setup are not correct, the condition that is not correct will be display in the middle display area. The calibration will not start. When the conditions are correct, press the "Next>" button in order to start the calibration of the fan speed. Note: When the minimum fan speed is being calibrated, the maximum signal will be sent to the hydraulic demand fan solenoid in order to obtain the minimum fan speed.Note: You can cancel the calibration at any time by pressing the "Cancel" button.
Illustration 11 g01113372
Typical example
Record the fan speed. Press button (5) or press button (6) at the bottom of the screen until the fan speed is approximately 1000 rpm. Then, press the button (6) at the bottom of the screen until the fan speed is correct. The minimum fan speed is 60 rpm. Note: When button (6) is pressed, the signal to the hydraulic demand fan solenoid will be increased. When the signal is increased, the fan speed will decrease. When button (5) is pressed, the signal to the hydraulic demand fan solenoid will be decreased. When the signal is decreased, the fan speed will increase.Note: When adjusting the minimum speed of the fan and the minimum speed is exceeded, increase the speed of the fan to 1000 rpm and then decrease the speed of the fan to 60 rpm. This will allow the fan speed to be properly set.
The calibration procedure could be stopped
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts harness Caterpillar catalog:
2417961
HARNESS AS-WIRING
R1600, R1600G, R1600H, R1700G
R1600, R1600G, R1600H, R1700G
2244760
HARNESS AS-SOLENOID
R1600, R1600G, R1600H
R1600, R1600G, R1600H
2246432
HARNESS AS-REAR LIGHTING
R1600, R1600G
R1600, R1600G
3430373
HARNESS AS-LIGHTING
Caterpillar
Caterpillar
3430088
HARNESS AS-LIGHTING
Caterpillar
Caterpillar
3386406
HARNESS AS-FRONT
Caterpillar
Caterpillar
3386412
HARNESS AS-CONTROL
Caterpillar
Caterpillar
3242043
HARNESS AS-CONTROL
Caterpillar
Caterpillar
3187778
HARNESS AS-CONTROL
Caterpillar
Caterpillar