Information:
Normal Mode
The AccuGrade system automatically operates in normal mode when you start up the display. In order to start the display, turn the key start switch to the ON position. Press the power key.By default, the following soft keys are available when the display is in normal mode.
Bucket Tip focus ("Bucket Tip: Left or Bucket Tip: Right")
Create Bucket
GPSYou can also use the "Setup Menu – Configuration" screen in order to perform the following when you are in "Normal Mode - Setup Menu - Configuration" mode.
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Beeper
Restore Settings
DiagnosticsService Mode
If you lack experience with the AccuGrade system, use extreme care when you are in service mode so that you do not accidentally change the AccuGrade system settings.
Configuration mode allows you to have access to all available options that the AccuGrade system offers.Use service mode in order to change the settings that affect the operation of the AccuGrade system.In order to turn on service mode, turn off the display if the display is ON. Press and hold down the "OK" key as you press the power key. Make sure that you hold down the "OK" key until the display shows the opening screen.In order to turn off service mode, turn off the display.Use the "Service" mode "Setup Menu - Configuration" screen in order to perform the following:
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
On-Grade Tolerance
Display and Lightbar Brightness
Map Recording
Avoidance Zones
Text Items
Beeper
Save Settings
Restore Settings
GPS Receiver Configuration
DiagnosticsUse the "Service" mode "Setup Menu - Installation" screen in order to perform the following:
Machine Settings
Units
Machine Dimensions
GPS Option Keys
Machine Radio Configuration
Lightbar Connections
Calibrate Sensors
Arm Sensor Connections
Wireless Communication Support
Production Reporting
Upgrade Firmware
Software Support Option
Guidance Hours
Select Language
Operator ConfigurationTurn the display off in order to exit serivce mode after editing the settings or performing tests on the GPS receiver. This ensures that inexperienced users will not inadvertently change the settings of the AccuGrade system.
The AccuGrade system automatically operates in normal mode when you start up the display. In order to start the display, turn the key start switch to the ON position. Press the power key.By default, the following soft keys are available when the display is in normal mode.
Bucket Tip focus ("Bucket Tip: Left or Bucket Tip: Right")
Create Bucket
GPSYou can also use the "Setup Menu – Configuration" screen in order to perform the following when you are in "Normal Mode - Setup Menu - Configuration" mode.
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
Display and Lightbar Brightness
Beeper
Restore Settings
DiagnosticsService Mode
If you lack experience with the AccuGrade system, use extreme care when you are in service mode so that you do not accidentally change the AccuGrade system settings.
Configuration mode allows you to have access to all available options that the AccuGrade system offers.Use service mode in order to change the settings that affect the operation of the AccuGrade system.In order to turn on service mode, turn off the display if the display is ON. Press and hold down the "OK" key as you press the power key. Make sure that you hold down the "OK" key until the display shows the opening screen.In order to turn off service mode, turn off the display.Use the "Service" mode "Setup Menu - Configuration" screen in order to perform the following:
Select Design
GPS Accuracy
Vertical Setup
Lightbar Scales
On-Grade Tolerance
Display and Lightbar Brightness
Map Recording
Avoidance Zones
Text Items
Beeper
Save Settings
Restore Settings
GPS Receiver Configuration
DiagnosticsUse the "Service" mode "Setup Menu - Installation" screen in order to perform the following:
Machine Settings
Units
Machine Dimensions
GPS Option Keys
Machine Radio Configuration
Lightbar Connections
Calibrate Sensors
Arm Sensor Connections
Wireless Communication Support
Production Reporting
Upgrade Firmware
Software Support Option
Guidance Hours
Select Language
Operator ConfigurationTurn the display off in order to exit serivce mode after editing the settings or performing tests on the GPS receiver. This ensures that inexperienced users will not inadvertently change the settings of the AccuGrade system.
Parts harness Caterpillar catalog:
2948598
HARNESS AS-SENSOR
TH35-C13T, TH35-C15T
TH35-C13T, TH35-C15T
3387129
HARNESS AS-PANEL
C27, C32
C27, C32
3387128
HARNESS AS-PANEL
C27, C32
C27, C32
3387084
HARNESS AS-PANEL
C27, C32
C27, C32
3387083
HARNESS AS-PANEL
C27, C32
C27, C32
3387111
HARNESS AS-SENSOR
C27, C32
C27, C32
3304141
HARNESS AS-PANEL
C9, TH35-C13I, TH35-C15I
C9, TH35-C13I, TH35-C15I
3304139
HARNESS AS-PANEL
TH35-C13I, TH35-C15I
TH35-C13I, TH35-C15I
2324604
HARNESS AS-PANEL
TH35-C15I
TH35-C15I
3327606
HARNESS AS-PANEL
C9, CX31-C13I, CX31-C15I, CX31-C9I, TH35-C11I, TH35-C13I, TH35-C15I
C9, CX31-C13I, CX31-C15I, CX31-C9I, TH35-C11I, TH35-C13I, TH35-C15I
3131354
HARNESS AS-POWER
CX31-C15I, CX35-P800, TH35-C15I
CX31-C15I, CX35-P800, TH35-C15I
3446076
HARNESS AS-ENGINE
TH35-C15I
TH35-C15I