Illustration 1 g03796793
Schematic of the Pattern Change Switch
This diagnostic code is associated with the Pattern Change Switch. This diagnostic code is recorded when inputs are either open or the inputs are shorted to the +battery circuit. This switch has three inputs to the ECM, two inputs are normally open and one is normally closed. During proper operation in one switch position, one normally open contact will be closed and the other normally open contact will remain open. When the switch is actuated to the opposite position, the first contact will be open and the other normally open contact will be closed.The possible causes for this diagnostic code are listed:
The switch is disconnected.
There is an open circuit in the wire harness.
Short to the +battery circuit in the harness.
The switch has failed.System Response:If the switch is faulted during operation, the last known value will be saved. If the switch is faulted at power up, the park brake will remain engaged and the implements will be locked out.Note: Table 1 contains wire numbers and connector contacts. Use this information to troubleshoot the failed circuit.
Table 1
Switch Continuity
Switch / CID Switch State Machine ECM Connector Contact No. Switch Contact Wire No. Status
CID 1007 Pattern Change Switch Not Actuated J2-57 N/O(1) N/O J753-BU(Blue) O(2)
J2-58 N/C(3) N/C P797-GN(Green) G(4)
J2-61 N/O N/O P796-OR(Orange) O
Actuated to "H" Position/#2 Alternate Pattern J2-57 N/O N/O J753-BU(Blue) G
J2-58 N/C N/C P797-GN(Green) O
J2-61 N/O N/O P796-OR(Orange) O
Actuated to "#1 Cat/ISO" Position J2-57 N/O N/O J753-BU(Blue) O
J2-58 N/C N/C P797-GN(Green) O
J2-61 N/O N/O P796-OR(Orange) G
(1) N/O = Normally Open.
(2) O = Open (no continuity to ground).
(3) N/C = Normally Closed.
(4) G = Grounded (continuity to ground).Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected.Ensure that the diagnostic code is active. Test Step 1. Check For Open Circuit
Turn the keyswitch to the OFF position.
Verify that the Pattern Change switch is connected.
Disconnect the harness from the ECM.
Activate the switch. At the harness connector for the ECM, check the continuity to ground of the normally closed contact and the normally open contacts. Expected Result:The continuity check does not agree with Table 1.Results:
YES - The continuity check does not agree with the preceding table. Proceed to Test Step 2.
NO - The continuity agrees with the values in the preceding table. Proceed to Test Step 3.Test Step 2. Check The Switch
Disconnect the harness from the switch.
At the harness connector for the ECM, check the continuity to ground of the normally closed contact and the normally open contact. Activate the switch when this check is being performed. Expected Result:The continuity check does not agree with the values in Table 1.Results:
YES - The continuity check does not agree with the preceding table.Repair: The switch has failed. Repair the switch or replace the switch.STOP
NO - The continuity check agrees with the preceding table.Repair: The harness has failed. Repair the harness or replace the harness.STOPTest Step 3. Check For A Short To + Battery
Check the continuity from each
Parts harness Caterpillar catalog:
5116194
HARNESS AS-
Caterpillar
Caterpillar
5116193
HARNESS AS-ENG
Caterpillar
Caterpillar
5116191
HARNESS AS
Caterpillar
Caterpillar
5116188
HARNESS AS
Caterpillar
Caterpillar
5116173
HARNESS AS
Caterpillar
Caterpillar
5115371
HARNESS AS
Caterpillar
Caterpillar
5121472
HARNESS AS
Caterpillar
Caterpillar
5120312
HARNESS AS-REL
Caterpillar
Caterpillar
5119415
HARNESS AS
Caterpillar
Caterpillar
5119067
HARNESS AS
Caterpillar
Caterpillar
5116204
HARNESS AS
Caterpillar
Caterpillar
5116196
HARNESS AS
Caterpillar
Caterpillar