Information:
Programming Governor Gain Parameters
The governor gain parameters are set at the factory. The factory default settings are recommended for most applications. The default settings should allow the engine to respond quickly to transient load changes. The default settings should allow the engine to remain stable during all operating conditions. If the factory default setting does not provide satisfactory performance, the governor gain parameters can be adjusted.The parameters in Table 1 can be adjusted.
Table 1
Parameter Valid Range
Governor Gain Factor 0 - 39999
Governor Minimum Stability Factor 0 - 39999
Governor Maximum Stability Factor 0 - 39999 Note: No engineering units are associated with the numbers in table 1.Note: The range of the programmable setting is wide for flexibility. Do not expect to use the whole range. If the programmable setting is greater than the valid range, the system will revert to the factory default value.Do not perform this procedure until you read this information and you understand this information.Gain Explanations
Governor Gain Factor
The "Governor Gain Factor" is multiplied by the engine speed error. This value is derived by calculating the difference between the desired speed and the actual speed.
If the "Governor Gain Factor" value is too large, the engine speed can overshoot the desired speed.
If the "Governor Gain Factor" value is too small, the engine will accelerate slowly.Governor Minimum/Maximum Stability Factor
The "Governor Minimum Stability Factor" functions in order to eliminate steady state speed error. The "Governor Minimum Stability Factor" is used by the Electronic Control Module (ECM) when the steady state speed error is less than 20 rpm.The "Governor Maximum Stability Factor" functions in order to eliminate steady state speed error. The "Governor Maximum Stability Factor" is used by the ECM when the steady state speed error is increasing and the engine speed error is greater than 20 rpm.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too high, the ECM will provide additional fuel. The additional fuel will cause the engine speed to overshoot. The additional fuel will also cause the engine speed to oscillate.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too low, the engine will not achieve a steady state operation quickly.Tuning Procedure
Turn the Engine Control Switch (ECS) to the COOLDOWN/STOP position. Connect the Caterpillar Electronic Technician (ET). Enable the engine overspeed protection prior to the adjustment procedure. Adjusting governor gain parameters without engine overspeed protection can result in serious engine damage. Ensure that engine overspeed protection is ON. Engine overspeed is configured on the setup screen of "Service Monitoring System" in Cat ET.
Personal injury or death can result from engine overspeed.If the engine overspeeds, it can cause injury or parts damage. The engine should be equipped with a separate shutdown device, to protect against engine overspeed. Do not use for emergency shutdown.
Start the engine. Observe the control panel to ensure that the engine has reached the rated speed. The control panel will serve as the reference point for engine speed during this procedure.
Go to the configuration parameters
The governor gain parameters are set at the factory. The factory default settings are recommended for most applications. The default settings should allow the engine to respond quickly to transient load changes. The default settings should allow the engine to remain stable during all operating conditions. If the factory default setting does not provide satisfactory performance, the governor gain parameters can be adjusted.The parameters in Table 1 can be adjusted.
Table 1
Parameter Valid Range
Governor Gain Factor 0 - 39999
Governor Minimum Stability Factor 0 - 39999
Governor Maximum Stability Factor 0 - 39999 Note: No engineering units are associated with the numbers in table 1.Note: The range of the programmable setting is wide for flexibility. Do not expect to use the whole range. If the programmable setting is greater than the valid range, the system will revert to the factory default value.Do not perform this procedure until you read this information and you understand this information.Gain Explanations
Governor Gain Factor
The "Governor Gain Factor" is multiplied by the engine speed error. This value is derived by calculating the difference between the desired speed and the actual speed.
If the "Governor Gain Factor" value is too large, the engine speed can overshoot the desired speed.
If the "Governor Gain Factor" value is too small, the engine will accelerate slowly.Governor Minimum/Maximum Stability Factor
The "Governor Minimum Stability Factor" functions in order to eliminate steady state speed error. The "Governor Minimum Stability Factor" is used by the Electronic Control Module (ECM) when the steady state speed error is less than 20 rpm.The "Governor Maximum Stability Factor" functions in order to eliminate steady state speed error. The "Governor Maximum Stability Factor" is used by the ECM when the steady state speed error is increasing and the engine speed error is greater than 20 rpm.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too high, the ECM will provide additional fuel. The additional fuel will cause the engine speed to overshoot. The additional fuel will also cause the engine speed to oscillate.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too low, the engine will not achieve a steady state operation quickly.Tuning Procedure
Turn the Engine Control Switch (ECS) to the COOLDOWN/STOP position. Connect the Caterpillar Electronic Technician (ET). Enable the engine overspeed protection prior to the adjustment procedure. Adjusting governor gain parameters without engine overspeed protection can result in serious engine damage. Ensure that engine overspeed protection is ON. Engine overspeed is configured on the setup screen of "Service Monitoring System" in Cat ET.
Personal injury or death can result from engine overspeed.If the engine overspeeds, it can cause injury or parts damage. The engine should be equipped with a separate shutdown device, to protect against engine overspeed. Do not use for emergency shutdown.
Start the engine. Observe the control panel to ensure that the engine has reached the rated speed. The control panel will serve as the reference point for engine speed during this procedure.
Go to the configuration parameters
Caterpillar SIS machinery equipment:
Caterpillar SIS
D4C & D4C LGP, XL Series III Hystat Tractors 4LS00001-UP (MACHINE) POWERED BY 3046 Engine »
142-1375
HEAD GP-MOTOR
D5C & D5C LGP, XL Series III Hystat Tractors 5HS00001-UP (MACHINE) POWERED BY 3046 Engine »
142-1375
HEAD GP-MOTOR
939C Track Loader Hydrostatic Drive 6DS00001-UP (MACHINE) POWERED BY 3046 Engine »
142-1375
HEAD GP-MOTOR
Caterpillar parts catalog:
Parts head Caterpillar catalog:
1469450
HEAD GP-PUMP
939C, D4C III, D5C III
939C, D4C III, D5C III
6E0775
HEAD
120K, 120M, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160K, 160M, 163H, 163H NA, 16G, 16H, 16H NA, 16M...
120K, 120M, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160K, 160M, 163H, 163H NA, 16G, 16H, 16H NA, 16M...
0947998
HEAD
311B, 315, 315B, 317B LN, 318B, 320 L, 320B, 933, 933C, 939, 939C, D3C III, D4C III, D5C III, E110B, E120, E120B, E140, E200B
311B, 315, 315B, 317B LN, 318B, 320 L, 320B, 933, 933C, 939, 939C, D3C III, D4C III, D5C III, E110B, E120, E120B, E140, E200B
1491484
HEAD
933, 933C, 939, 939C, D3C III, D4C III, D5C III
933, 933C, 939, 939C, D3C III, D4C III, D5C III
1421381
HEAD
939C, D4C III, D5C III
939C, D4C III, D5C III
1469452
HEAD-MOTOR
939C, D4C III, D5C III
939C, D4C III, D5C III
1469539
HEAD-MOTOR
939C, D4C III, D5C III
939C, D4C III, D5C III
1229842
HEAD
824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, 826K, 918F, 924F, 928F, 939C, 980G
824G, 824G II, 824H, 824K, 825G, 825G II, 825H, 825K, 826G, 826G II, 826H, 826K, 918F, 924F, 928F, 939C, 980G
1908123
HEAD GP-MOTOR
M312, M313C
M312, M313C
3657707
HEAD GP-PUMP
966K, 972K
966K, 972K
1687791
HEAD GP-GRAPPLE
525, 525B
525, 525B
3133391
HEAD GP-PUMP
CP-533E, CS-533E, CS-54
CP-533E, CS-533E, CS-54
1576017
HEAD GP-GRAPPLE
515, 517, 525
515, 517, 525
6E6316
HEAD GP-PUMP CONTROL
322 FM L, 325 FM L, 325 L, 330, 330 FM L, 330 L
322 FM L, 325 FM L, 325 L, 330, 330 FM L, 330 L
2959660
HEAD GP-PUMP
330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, M330D
330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 340D L, 340D2 L, M330D
1983809
HEAD GP-PUMP
TK1051, TK711, TK721, TK722, TK732
TK1051, TK711, TK721, TK722, TK732
3411510
HEAD GP-PUMP
D5R LGP, D6N, D6N LGP, D6N OEM
D5R LGP, D6N, D6N LGP, D6N OEM