2128562 HEAD AS-CYL Caterpillar parts
Rating:
Alternative (cross code) number:
CA2128562
212-8562
2128562
CA2128562
212-8562
2128562
Weight: 53 pounds 24 kg.
Information:
Illustration 1 g01384636
Schematic of the Lockup Clutch SolenoidThis diagnostic code is associated with the Lockup Clutch Solenoid. The FMI 06 means that the ECM has determined that the current of the solenoid is above normal. The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 679 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:There is no change in system operation.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 0679 FMI 06 changes to CID 0679 FMI 05 when the solenoid is disconnected.Results:
YES - CID 0679 FMI 06 changes to CID 0679 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - CID 0679 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-13 (wire G747-OR) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-13 (wire G747-OR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0679 FMI 06. Expected Result:The CID 0679 FMI 06 is active. Results:
YES - The CID 0679 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". STOP
NO - The CID 0679 FMI 06 is not active. The diagnostic code does not
Parts head Caterpillar catalog:
2126071
HEAD AS
Caterpillar
Caterpillar
2125094
HEAD AS
Caterpillar
Caterpillar
2123381
HEAD AR-
Caterpillar
Caterpillar
2120941
HEAD GP-
Caterpillar
Caterpillar
2120638
HEAD-CYLINDER
Caterpillar
Caterpillar
2120363
HEAD-CYLINDER
Caterpillar
Caterpillar
2165393
HEAD AR-
Caterpillar
Caterpillar
2162168
HEAD-MOTOR
Caterpillar
Caterpillar
2157230
HEAD AR-
Caterpillar
Caterpillar
2145651
HEAD-CYLINDER
Caterpillar
Caterpillar
2143846
HEAD
Caterpillar
Caterpillar
2128564
HEAD AS-CYL
Caterpillar
Caterpillar