4C6390 HEAT SHRINK TUBE Caterpillar parts
RT100
Rating:
Alternative (cross code) number:
CA4C6390
4C-6390
4C6390
CA4C6390
4C-6390
4C6390
Weight: 0.16 pounds 0 kg.
TELEHANDLER,
Compatible equipment models: 4C6390:
Information:
Spark Plug
Illustration 1 g00649990
(1) Spark plug Torque ... 30 4 N m (22 3 lb ft) (2) Spark plug gap Gap ... 0.64 0.03 mm (0.025 0.001 inch)Spark Plug Adapter
Illustration 2 g00608996
Put liquid soap on the seal (2) . Put 5P-3931 Anti-Seize Compound on the threads of the adapter (1) . Put 5P-3931 Anti-Seize Compound on the threads in the cylinder head (3) . Replace the gasket (iron) (4) when the spark plug adapter is removed and installed. (1) Spark plug adapter Torque ... 95 7 N m (70 5 lb ft)Transformers
Transformer for Spark Gap Magneto
Illustration 3 g00649992
The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 6 ohms 5 percentThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 10,500 ohms 5 percentTransformer for Fairbanks Morse Solid State Magneto
ReferenceSee illustration 3.The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 0.3 to 0.6 ohmsThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 11,000 to 13,000 ohmsTransformer for Altronic Solid State Magneto
Illustration 4 g00649995
The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 0.1 to 0.2 ohmsThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 5,000 to 8,000 ohmsTransformer for Altronic Integral Solid State Magneto
Illustration 5 g00650000
The resistance of the primary coil is measured between the positive pin A (1) and the negative pin B (2) of the transformer. ... 0.2 to 1.2 ohmsThe resistance of the secondary coil is measured between the outlet for the high current (3) and the case. ... 8,000 to 10,000 ohmsWhen you install the transformer which is attached to the spark plug, turn 1/8 past finger tight. Do not exceed the following torque. ... 6.7 N m (60 lb in)Note: Do not use any thread lubricant between the transformer and the spark plug.
Illustration 1 g00649990
(1) Spark plug Torque ... 30 4 N m (22 3 lb ft) (2) Spark plug gap Gap ... 0.64 0.03 mm (0.025 0.001 inch)Spark Plug Adapter
Illustration 2 g00608996
Put liquid soap on the seal (2) . Put 5P-3931 Anti-Seize Compound on the threads of the adapter (1) . Put 5P-3931 Anti-Seize Compound on the threads in the cylinder head (3) . Replace the gasket (iron) (4) when the spark plug adapter is removed and installed. (1) Spark plug adapter Torque ... 95 7 N m (70 5 lb ft)Transformers
Transformer for Spark Gap Magneto
Illustration 3 g00649992
The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 6 ohms 5 percentThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 10,500 ohms 5 percentTransformer for Fairbanks Morse Solid State Magneto
ReferenceSee illustration 3.The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 0.3 to 0.6 ohmsThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 11,000 to 13,000 ohmsTransformer for Altronic Solid State Magneto
Illustration 4 g00649995
The resistance of the primary coil is measured between the positive terminal (1) and the negative terminal (2) of the transformer. ... 0.1 to 0.2 ohmsThe resistance of the secondary coil is measured between the negative terminal (2) of the transformer and the outlet (3) for the high current. ... 5,000 to 8,000 ohmsTransformer for Altronic Integral Solid State Magneto
Illustration 5 g00650000
The resistance of the primary coil is measured between the positive pin A (1) and the negative pin B (2) of the transformer. ... 0.2 to 1.2 ohmsThe resistance of the secondary coil is measured between the outlet for the high current (3) and the case. ... 8,000 to 10,000 ohmsWhen you install the transformer which is attached to the spark plug, turn 1/8 past finger tight. Do not exceed the following torque. ... 6.7 N m (60 lb in)Note: Do not use any thread lubricant between the transformer and the spark plug.
Caterpillar parts catalog:
Parts heat Caterpillar catalog:
0985625
HEAT SHRINK SLEEVING
RT100, RT50
RT100, RT50
0985625
HEAT SHRINK SLEEVING
RT100, RT50
RT100, RT50
3202360
HEAT SHIELD
420E, 430E, 450E, C4.4, CW-34, D3K XL, D4K XL, D5K LGP
420E, 430E, 450E, C4.4, CW-34, D3K XL, D4K XL, D5K LGP
9S2292
HEAT SINK AS
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 235, 3114, 3116, 3126, 3126B, 317...
4P4608
HEAT SINK
3406C, 3412, 3412C, 3456, C15, C18, C27, G3408, G3412, PM3412
3406C, 3412, 3412C, 3456, C15, C18, C27, G3408, G3412, PM3412
4P4610
HEAT SINK
3408, 3408C, 3412, 3508, 3512, 3516, G3408, G3408B, G3412, G3512, G3516, SR4
3408, 3408C, 3412, 3508, 3512, 3516, G3408, G3408B, G3412, G3512, G3516, SR4
4P3154
HEAT SINK
3208, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3456, C15, C9, G3306, G3406, PM3456
3208, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3456, C15, C9, G3306, G3406, PM3456
5N2213
HEAT SINK AS
3304, 3304B, 3306, 3406, 3406B, 3412, 3412C, G3306, G3412
3304, 3304B, 3306, 3406, 3406B, 3412, 3412C, G3306, G3412
7W4471
HEAT SINK AS-NEGATIVE
3208, 3304, 3304B
3208, 3304, 3304B
3N8970
HEAT SINK AS-POSITIVE
3208, 3304, 3304B
3208, 3304, 3304B