AVSPARE.COM
parts catalog

HEAT EXCHANGER 7F6141 - Caterpillar


7F6141 HEAT EXCHANGER Caterpillar parts
Rating:
61
Alternative (cross code) number:
CA7F6141
7F-6141
7F6141
Caterpillar 7F6141 HEAT EXCHANGER
Weight: 1 pounds 0 kg.

Buy HEAT EXCHANGER 7F6141 Caterpillar genuine, new aftermarket tractor parts with delivery

  For full view, you need register

Information:

Accessing Calibrations
Connect Cat® ET to the Steering ECM. After communication has been established, Cat® ET will list the electronic control modules that are on the machine. Choose the menu item "Steering ECM". Select the drop-down menu that is called "Service". Then, select the "Calibration" function. The list of calibrations will appear.
Illustration 1 g01355318
Typical example of the calibration screen
Once the specific calibration is selected, the Cat® ET display will guide you through the calibration procedure.The Cat® ET display will list initial machine conditions that must be satisfied before the ECM will allow the calibration procedure to continue. Follow the specific instructions on the display to complete the calibration procedure.Note: Turn the Key switch to the off position after any calibration. The calibration may not be flagged if the key switch is not cycled.Position Sensor (Steering Cylinder) - Calibration
Cat® ET is required for the calibration of the "Arm Steering System" solenoid. The screen shots included in this section of the manual are to be used as a guide for the process.
Illustration 2 g06122366
Locate the available control modules within Cat® ET. Expand the options under "Steering ECM". Select the "Steering Cylinder Position Sensor" option. Click "START" in the lower left corner of the screen.
Illustration 3 g06122363
The conditions required to begin the calibration are listed in Cat® ET.
(1.) Cylinder parameters must be programmed prior to performing this calibration.
(2.) Engine must be running and set to high idle.
(3.) Parking brake must be released.
(4.) Place machine in Manual steering mode.
(5.) Machine must be positioned so that it can be driven in a straight line on a smooth surface for at least several hundred yards.
(6.) After all conditions are satisfied click "NEXT" at the bottom left corner of the screen to begin.
Illustration 4 g06122371
The operator is instructed to maintain a speed of 10 km/h (7 mph) while driving the machine. Continue to operate the machine until a window appears on the screen indicating that the calibration is successful.
Illustration 5 g06122375
Calibration of Steering Cylinder Position Sensor completed.
Arm Steering System Solenoid - Calibration
Illustration 6 g06122366
Return to the list of control modules within Cat® ET. Expand the options under "Steering ECM". Select the "Arm Steering Systems/Solenoid Calibration" option. Click "START" in the lower left corner of the screen.
Illustration 7 g06122376
The conditions required to begin the calibration are listed in Cat® ET.
(1.) Cylinder parameters must be programmed prior to performing this calibration.
(2.) The "Autonomous


Parts heat Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.