1682599 HOSE AS Caterpillar parts
D6R, D6R II, D6R III, D6R STD, D6T
Rating:
Alternative (cross code) number:
CA1682599
168-2599
1682599
CA1682599
168-2599
1682599
Weight: 3 pounds 1 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 1682599 Hoses for Models D6R/D6R II/D6R III/D6R STD/D6T
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
CTP 1682599 Hoses for Models D6R/D6R II/D6R III/D6R STD/D6T
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
CTP 1682599 Hoses for Models D6R/D6R II/D6R III/D6R STD/D6T
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
CTP A hydraulic hose system consists of high pressure hydraulic hose and tubing, machines and components || Specialized hydraulic line fittings for securing the line || Hydraulic hoses are used for high pressure fluid power applications on mobile and fixed machinery
Information:
MID 027 CID 1406 FMI 03Conditions Which Generate This Code:
Illustration 1 g01310888
Connection of the solenoid valve
This diagnostic code is associated with the solenoid valve. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic code are listed:
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1406 FMI 03 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the ON position.
Disconnect the wires from the back of the connector at the ECM.
At the machine harness connector for the solenoid, measure the voltage from contact 1 (wire J834-PU(Purple)) to frame ground. At the machine harness connector for the solenoid, measure the voltage from contact 2 (wire H802-GY(Grey)) to frame ground. Expected Result:The voltage is 0 VDC.Results:
OK - There are no shorts in the wires. Proceed to Test Step 2.
NOT OK - A voltage is present in the wires. There is a short in the machine harness or in the wires. The short is to a separate voltage source.Repair: Repair the machine harness or replace the machine harness. Ensure that the fix has corrected the problem.STOPTest Step 2. CHECK THE OPERATION OF THE ECM.The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
Remove wire (J834-PU(Purple)) from the harness connector contact J1-48.
Reconnect the machine harness connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active diagnostic code. Expected Result:The diagnostic code of a FMI 03 changes to a FMI 05.Results:
OK - The FMI 03 changes to a FMI 05. The FMI 05 was activated after the energize circuit for the solenoid was disconnected. The ECM has responded correctly to the condition of an open circuit in the solenoid circuit. Reconnect the disconnected wire. Wire (J834-PU(Purple)) connects to the ECM at connector contact J1-48. Proceed to Test Step 3.
NOT OK - The FMI 03 does not change to a FMI 05. The ECM has failed.Repair: The ECM has not responded correctly to the condition of an open circuit in the solenoid circuit. The operation of the ECM is not correct. Replace the ECM. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires
Illustration 1 g01310888
Connection of the solenoid valve
This diagnostic code is associated with the solenoid valve. The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic code are listed:
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1406 FMI 03 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the ON position.
Disconnect the wires from the back of the connector at the ECM.
At the machine harness connector for the solenoid, measure the voltage from contact 1 (wire J834-PU(Purple)) to frame ground. At the machine harness connector for the solenoid, measure the voltage from contact 2 (wire H802-GY(Grey)) to frame ground. Expected Result:The voltage is 0 VDC.Results:
OK - There are no shorts in the wires. Proceed to Test Step 2.
NOT OK - A voltage is present in the wires. There is a short in the machine harness or in the wires. The short is to a separate voltage source.Repair: Repair the machine harness or replace the machine harness. Ensure that the fix has corrected the problem.STOPTest Step 2. CHECK THE OPERATION OF THE ECM.The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
Remove wire (J834-PU(Purple)) from the harness connector contact J1-48.
Reconnect the machine harness connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active diagnostic code. Expected Result:The diagnostic code of a FMI 03 changes to a FMI 05.Results:
OK - The FMI 03 changes to a FMI 05. The FMI 05 was activated after the energize circuit for the solenoid was disconnected. The ECM has responded correctly to the condition of an open circuit in the solenoid circuit. Reconnect the disconnected wire. Wire (J834-PU(Purple)) connects to the ECM at connector contact J1-48. Proceed to Test Step 3.
NOT OK - The FMI 03 does not change to a FMI 05. The ECM has failed.Repair: The ECM has not responded correctly to the condition of an open circuit in the solenoid circuit. The operation of the ECM is not correct. Replace the ECM. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires
Cat SIS web machinery list:
Parts hose Caterpillar catalog:
1850844
HOSE
D6R, D6R II, D6R III, D6T
D6R, D6R II, D6R III, D6T
2131724
HOSE
D6R, D6R II, D6R III, D6T, D8L
D6R, D6R II, D6R III, D6T, D8L
1881019
HOSE
966F II, D6R II
966F II, D6R II
2506052
HOSE
D6R, D6R II, D6R III, D6R STD, D6T
D6R, D6R II, D6R III, D6R STD, D6T
2517214
HOSE
24M, D6R, D6R II, D6R III, D6R STD, D6T
24M, D6R, D6R II, D6R III, D6R STD, D6T
2242228
HOSE AS
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
1746127
HOSE AS
D6R II
D6R II
2065939
HOSE AS
D6R II, D8R
D6R II, D8R
1725398
HOSE AS
D6R II, D7R II, D8T, D9T
D6R II, D7R II, D8T, D9T
2267140
HOSE AS
D6R III
D6R III
1631619
HOSE AS
D6R, D8L, D9N, D9R
D6R, D8L, D9N, D9R
1739430
HOSE ASSEM.
D6R II
D6R II
7T6934
HOSE AS
D5H XL, D5R LGP, D6H, D6H II, D6H XL, D6H XR, D6M, D6N, D6N LGP, D6R, D6R II, D6R III, D6R STD, D6T
D5H XL, D5R LGP, D6H, D6H II, D6H XL, D6H XR, D6M, D6N, D6N LGP, D6R, D6R II, D6R III, D6R STD, D6T
6Y3476
HOSE AS
D6H, D6H XL, D6R, D6R II, D6R III, D6T
D6H, D6H XL, D6R, D6R II, D6R III, D6T
6Y3475
HOSE AS
D6H, D6H XL, D6R, D6R II, D6R III, D6T
D6H, D6H XL, D6R, D6R II, D6R III, D6T
4Z8920
HOSE AS
D6R, D6R II
D6R, D6R II
4Z8919
HOSE AS
D6R, D6R II
D6R, D6R II
1777983
HOSE AS
D6R, D6R II, D6R III, D6R STD, D6T
D6R, D6R II, D6R III, D6R STD, D6T
1086013
HOSE AS
D6R, D6R II
D6R, D6R II
7T6931
HOSE AS
D5H XL, D6H, D6H II, D6H XL, D6H XR, D6M, D6N, D6R, D6R II
D5H XL, D6H, D6H II, D6H XL, D6H XR, D6M, D6N, D6R, D6R II
6Y3474
HOSE AS
D6H, D6H II, D6H XR, D6R, D6R II, D6R III
D6H, D6H II, D6H XR, D6R, D6R II, D6R III
6Y3472
HOSE AS
D6H, D6H II, D6H XR, D6R, D6R II, D6R III
D6H, D6H II, D6H XR, D6R, D6R II, D6R III
4Z8955
HOSE AS
D6R, D6R II
D6R, D6R II
4Z8954
HOSE AS
D6R, D6R II
D6R, D6R II