1U0807 HOSE AS Caterpillar parts
814B, 814F, 814F II, 815B, 815F
Rating:
Alternative (cross code) number:
CA1U0807
1U-0807
1U0807
CA1U0807
1U-0807
1U0807
Weight: 5 pounds 2 kg.
SOIL COMPACTOR, WHEEL DOZER,
Compatible equipment models: 1U0807:
Information:
Illustration 1 g01449856
Circuit of the Implement Power Management SolenoidThis diagnostic code is associated with the Hydraulic Pump Torque Limit Solenoid (Implement Power Management Solenoid). The FMI 06 means that the ECM has determined that there is a short to ground in the solenoid circuit.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the circuit are clean and secure. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2970 FMI 06 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:The FMI 06 changes to FMI 05 when the solenoid is disconnected.Results:
YES - The FMI 06 changes to FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NO - The FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J1-52 (wire P988-OR) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-52 (wire P988-OR) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
1U3578
HOSE AS
815B, 815F
815B, 815F
3654627
HOSE AS
815B, 815F, 815F II
815B, 815F, 815F II
4T2173
HOSE AS
815B, 815F, 815F II
815B, 815F, 815F II
5V1226
HOSE AS
814B, 815B
814B, 815B
5V1225
HOSE AS
814B, 815B
814B, 815B
8V9326
HOSE AS
814B, 815B
814B, 815B
8R8559
HOSE AS
824C, 826C
824C, 826C
2V4818
HOSE AS
824C, 826C
824C, 826C
1118810
HOSE AS
814B, 815B, 816B
814B, 815B, 816B
1119841
HOSE AS
814B, 815B
814B, 815B
1119793
HOSE AS
814B, 815B, 816B, 826C
814B, 815B, 816B, 826C
1119794
HOSE AS
814B, 815B, 816B, 826C
814B, 815B, 816B, 826C