Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The tolerance stack up of components in the HVAC system may result in voltage over the recommended limit on certain machines listed above. Voltage which exceeds the upper threshold causes fault code "2661-3" to activate.Solution
Table 1
Required Part List
Item Qty New Part Number Description
1 1 115-8109 Wire Splice
2 1 207-3814 Wire As
Illustration 1 g06255193
Typical example
Control Panel
(1) 115-8109 Wire Splice
(2) 207-3814 Wire AsThe high voltage will not shutdown the HVAC system, but will cause the fault code "2661-3" to be displayed. To reduce the voltage to an acceptable level, and eliminate the fault code, perform the following procedure.
Remove the Temperature Control Panel.
Disconnect the 12-pin Deutsch connector from the back of the control panel.
Remove wire from location 11 of the 12-pin Deutsch connector. Leave the socket on the wire.
Use wire splice (1) to connect the freed wire to the single pin end of wire assembly (2). Refer to Illustration 1.
Insert two socket ends of wire assembly (2) into location 11 and 12 on the 12-pin Deutsch connector. Refer to Illustration 1.
Reconnect the 12-pin Deutsch connector to the back of the Control Panel.
Reinstall the Control Panel.
The problem that is identified below does not have a known permanent solution. Until a permanent solution is known, use the solution that is identified below.Problem
The tolerance stack up of components in the HVAC system may result in voltage over the recommended limit on certain machines listed above. Voltage which exceeds the upper threshold causes fault code "2661-3" to activate.Solution
Table 1
Required Part List
Item Qty New Part Number Description
1 1 115-8109 Wire Splice
2 1 207-3814 Wire As
Illustration 1 g06255193
Typical example
Control Panel
(1) 115-8109 Wire Splice
(2) 207-3814 Wire AsThe high voltage will not shutdown the HVAC system, but will cause the fault code "2661-3" to be displayed. To reduce the voltage to an acceptable level, and eliminate the fault code, perform the following procedure.
Remove the Temperature Control Panel.
Disconnect the 12-pin Deutsch connector from the back of the control panel.
Remove wire from location 11 of the 12-pin Deutsch connector. Leave the socket on the wire.
Use wire splice (1) to connect the freed wire to the single pin end of wire assembly (2). Refer to Illustration 1.
Insert two socket ends of wire assembly (2) into location 11 and 12 on the 12-pin Deutsch connector. Refer to Illustration 1.
Reconnect the 12-pin Deutsch connector to the back of the Control Panel.
Reinstall the Control Panel.
Parts hose Caterpillar catalog:
1U8330
HOSE AS-BRAKE
Caterpillar
Caterpillar
1U8326
HOSE AS-INLET
Caterpillar
Caterpillar
1U8219
HOSE AS-
Caterpillar
Caterpillar
1U8218
HOSE AS-
Caterpillar
Caterpillar
1U8217
HOSE AS-
Caterpillar
Caterpillar
1U8216
HOSE AS-
Caterpillar
Caterpillar
1U9650
HOSE AS
Caterpillar
Caterpillar
1U9649
HOSE AS
Caterpillar
Caterpillar
1U9144
HOSE
Caterpillar
Caterpillar
1U9143
HOSE
Caterpillar
Caterpillar
1U9137
HOSE AS-LUBE
Caterpillar
Caterpillar
1U9136
HOSE AS-AIR
Caterpillar
Caterpillar