2703438 HOSE AS Caterpillar parts
D6R, D6R III, D6R STD, D6T, D6T LGP, D6T XL
Rating:
Alternative (cross code) number:
CA2703438
270-3438
2703438
CA2703438
270-3438
2703438
TRACK-TYPE TRACTOR,
Compatible equipment models: 2703438:
Information:
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
"K1"     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1 can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0482 FMI 04 is a short circuit of the "K6" relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0482 FMI 04 is active.Note: The "DIAG" indicator will be flashing and the CID 0482 FMI 04 will be present on the display if the diagnostic code is active.Expected Result:A CID 0482 FMI 04 is displayed as an active diagnostic code or the diagnostic code is inactive.Results:
OK
Cat SIS web machinery list:
Parts hose Caterpillar catalog:
2086726
HOSE AS
D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
2089699
HOSE AS
D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
3W2470
HOSE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD
9W9083
HOSE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T XL
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T XL
9W9082
HOSE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T XL
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T XL
1117057
HOSE AS
D6R, D6R III, D7R, D7R II
D6R, D6R III, D7R, D7R II
1850844
HOSE
D6R, D6R II, D6R III, D6T
D6R, D6R II, D6R III, D6T
2131724
HOSE
D6R, D6R II, D6R III, D6T, D8L
D6R, D6R II, D6R III, D6T, D8L
2506052
HOSE
D6R, D6R II, D6R III, D6R STD, D6T
D6R, D6R II, D6R III, D6R STD, D6T
2517214
HOSE
24M, D6R, D6R II, D6R III, D6R STD, D6T
24M, D6R, D6R II, D6R III, D6R STD, D6T
2242228
HOSE AS
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
D6R, D6R II, D6R III, D6R STD, D6T, D7R XR
2267140
HOSE AS
D6R III
D6R III
2633346
HOSE AS
D6R III, D6T, D6T XL
D6R III, D6T, D6T XL
3738359
HOSE AS
627H, D6T LGP, D6T XL, D7E, D7E LGP
627H, D6T LGP, D6T XL, D7E, D7E LGP
3486810
HOSE AS
627H, 627K, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP
627H, 627K, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP
3486809
HOSE AS
627H, 627K, 627K LRC, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP
627H, 627K, 627K LRC, D6T LGP, D6T LGPPAT, D6T XL, D7E, D7E LGP
3251569
HOSE AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3251568
HOSE AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3464123
HOSE AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3464122
HOSE AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3251589
HOSE AS
D6T LGP, D6T XL
D6T LGP, D6T XL
3251588
HOSE AS
D6T XL
D6T XL
2943345
HOSE AS
D6T, D6T LGP, D6T XL
D6T, D6T LGP, D6T XL
2720251
HOSE AS
D6T, D6T XL
D6T, D6T XL