Outputs
The discrete I/O module has eight "Form C" relay outputs. Each output can be configured to signal one of many possible events. Each output can be configured for either general events or for specific events. The Cat ET Service Tool (CST) is used in order to configure the discrete I/O module outputs.For general events, each output activates whenever any "Alarm Condition", "Shutdown Condition", or any combination of the two conditions exist.For specific events, each output activates whenever the diagnostic message contains the SPN and Failure Mode Identifier (FMI) combination that matches the SPN and FMI combination that is programmed for that particular output.The FMI defines the nature of the event, such as above range or below range. The FMI includes events such as high or low alarms, shutdowns, or condition exists.The output configuration parameters are shown in table 3.
Table 3
Configuration Parameters for Each Output    
Set Point Parameter    Range    
Output #nn SPN     Any SPN supported by EMCP 3    
Output #nn Trigger Condition     Disabled        
    Specific     Condition Exists
Open Circuit Diagnostic
High Shutdown
High Warning
Low Shutdown
Low Warning
Warning or Shutdown
Warning, Shutdown, or Short Circuit Diagnostic    
    General     Open Circuit Diagnostic
Shutdown
Warning
Warning, Shutdown, or Short Circuit Diagnostic    Configuration Behaviors
The discrete I/O module exhibits the following configuration behaviors.
Maintains functionality with no loss in performance during single set point configuration
Maintains functionality with no loss in performance while communicating on the data link
Retains all configured values in non-volatile memory
Configured on the secondary data link (CAN2) using the CST.Specifications
Table 4 lists the specifications for the input/output module.
Table 4
Input/Output Module Specifications    
Nominal Voltage     9 VDC to 32 VDC    
Operating Voltage Range     12 VDC
24 VDC (external power supplies)    
Ambient Operating Temperature     -40 degrees Celsius to 70 degrees Celsius    
Output Relay Contact Ratings     2A @120 VAC
2A @ 30 VDC
2A @ 277 VAC    
The discrete I/O module has eight "Form C" relay outputs. Each output can be configured to signal one of many possible events. Each output can be configured for either general events or for specific events. The Cat ET Service Tool (CST) is used in order to configure the discrete I/O module outputs.For general events, each output activates whenever any "Alarm Condition", "Shutdown Condition", or any combination of the two conditions exist.For specific events, each output activates whenever the diagnostic message contains the SPN and Failure Mode Identifier (FMI) combination that matches the SPN and FMI combination that is programmed for that particular output.The FMI defines the nature of the event, such as above range or below range. The FMI includes events such as high or low alarms, shutdowns, or condition exists.The output configuration parameters are shown in table 3.
Table 3
Configuration Parameters for Each Output    
Set Point Parameter    Range    
Output #nn SPN     Any SPN supported by EMCP 3    
Output #nn Trigger Condition     Disabled        
    Specific     Condition Exists
Open Circuit Diagnostic
High Shutdown
High Warning
Low Shutdown
Low Warning
Warning or Shutdown
Warning, Shutdown, or Short Circuit Diagnostic    
    General     Open Circuit Diagnostic
Shutdown
Warning
Warning, Shutdown, or Short Circuit Diagnostic    Configuration Behaviors
The discrete I/O module exhibits the following configuration behaviors.
Maintains functionality with no loss in performance during single set point configuration
Maintains functionality with no loss in performance while communicating on the data link
Retains all configured values in non-volatile memory
Configured on the secondary data link (CAN2) using the CST.Specifications
Table 4 lists the specifications for the input/output module.
Table 4
Input/Output Module Specifications    
Nominal Voltage     9 VDC to 32 VDC    
Operating Voltage Range     12 VDC
24 VDC (external power supplies)    
Ambient Operating Temperature     -40 degrees Celsius to 70 degrees Celsius    
Output Relay Contact Ratings     2A @120 VAC
2A @ 30 VDC
2A @ 277 VAC    
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
3650161
HOSE
Caterpillar
Caterpillar
3650160
HOSE
Caterpillar
Caterpillar
3650148
HOSE
Caterpillar
Caterpillar
3650144
HOSE AS
Caterpillar
Caterpillar
3650142
HOSE AS
Caterpillar
Caterpillar
3650141
HOSE AS
Caterpillar
Caterpillar
3718125
HOSE
Caterpillar
Caterpillar
3679506
HOSE
Caterpillar
Caterpillar
3675444
HOSE AS
Caterpillar
Caterpillar
3650182
HOSE
Caterpillar
Caterpillar
3650179
HOSE AS
Caterpillar
Caterpillar
3650178
HOSE AS
Caterpillar
Caterpillar