3848410 HOSE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA3848410
384-8410
3848410
CA3848410
384-8410
3848410
Weight: 0.96 pounds 0 kg.
Information:
Illustration 1 g00899816
Voltage Droop Control (Typical Example) (1) Voltage droop transformer T1 (2) Lead (3) Main stator (4) K65-12B voltage regulatorThere are two primary requirements for parallel operation:
Generator engines should share the real power requirements (kW) of the electrical load.
Generators should share the reactive power requirements (KVAR) of the electrical load.
Illustration 2 g01021519
The Cat K65-12B Voltage Regulator presents an electrical shock/electrocution hazard. This hazard will cause serious injury or death. Service by trained personnel only.The terminals and heat sinks are live at hazardous voltages when power is applied and for up to 8 minutes after power is removed.
The engine governors will control sharing of the real power requirements (kW). The voltage regulator will control sharing of the reactive power requirements (KVAR) of the total system load. Occasionally, one generator output voltage is slightly higher than the other generators. This will supply lagging reactive current flow to the other generators that are connected in the group. The lagging reactive current flow will circulate between generators. This could possibly cause an ampere overloading.In order to share reactive loads, an individual generator output voltage droops in proportion to the lagging reactive current flow. The reactive current flow is measured with a current transformer (CT). As reactive generator output current increases, the regulator will cause the output voltage to lower proportionally. If the measured reactive current is leading, the output voltage will rise. In either case, this action will tend to reduce the reactive current for better sharing of KVAR with other units.The following items are required in order to provide the voltage droop function:
1 Ampere CT or 5 Ampere CT (1)
wiring harness
Illustration 3 g01021519
The Cat K65-12B Voltage Regulator presents an electrical shock/electrocution hazard. This hazard will cause serious injury or death. Service by trained personnel only.The terminals and heat sinks are live at hazardous voltages when power is applied and for up to 8 minutes after power is removed.
The droop transformer senses load current in lead "T2" (2) of 6 lead generators. The droop adjustment adjusts the droop voltage. The transformer may be standard on some generators or an attachment on other generators. The wiring harness may be standard on some generators or an attachment on other generators.Note: At full rated current (1 Ampere or 5 Ampere), the droop adjustment is up to 10%. As the CT current decreases, the amount of droop adjustment decreases proportionally. It is important to size the CT correctly for the load which will be carried by the generator.
Parts hose Caterpillar catalog:
3848281
HOSE AS
Caterpillar
Caterpillar
3848280
HOSE AS
Caterpillar
Caterpillar
3848279
HOSE AS
Caterpillar
Caterpillar
3848278
HOSE AS
Caterpillar
Caterpillar
3848080
HOSE AS
Caterpillar
Caterpillar
3848079
HOSE AS
Caterpillar
Caterpillar
3848520
HOSE AS
Caterpillar
Caterpillar
3848518
HOSE AS
Caterpillar
Caterpillar
3848517
HOSE AS
Caterpillar
Caterpillar
3848516
HOSE AS
Caterpillar
Caterpillar
3848515
HOSE AS
Caterpillar
Caterpillar
3848514
HOSE AS
Caterpillar
Caterpillar