4168441 HOSE AS Caterpillar parts
329D, 329D L
Rating:
Alternative (cross code) number:
CA4168441
416-8441
4168441
CA4168441
416-8441
4168441
Weight: 11 pounds 5 kg.
EXCAVATOR, MOBILE HYD POWER UNIT,
Information:
Failure Mode Identifier
The codes for the Failure Mode Identifier (FMI) are defined by the Society Of Automotive Engineers Inc. (SAE). The Table 4 contains the CAT definitions for the FMI. Diagram 1 illustrates FMI codes that can be generated from a sensor that has failed.
Illustration 1 g00493694
Range of possible FMI codes generated from a failed sensor
Table 4
Failure Mode Identifier Definitions
FMI Failure Description
0 Data valid but above normal operating range
1 Data valid but below normal operating range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
4 Voltage below normal or shorted low
5 Current below normal or open circuit
6 Current above normal or grounded circuit
7 Mechanical system not responding properly
8 Abnormal frequency, pulse, or period
9 Abnormal update
10 Abnormal rate of change
11 Failure mode not identifiable
12 Bad device or component
13 Out of calibration
14 Special Instruction Detailed FMI Explanation
FMI 0 "Data Valid But Above Normal Operating Range" - Every electronic control system has a high limit setting for the expected operating range of the signal. The high limit includes over range signals. A sensor that is still operating but sending a signal above the expected limit will cause an FMI 00 to be recorded.Some possible causes of an FMI 00 are:
The signal is above normal
The signal is shorted to the +battery circuit
The sensor is out of calibrationThe following is an example of a sensor that needs calibration. A PWM signal with an 80% duty cycle is a valid signal. If the PWM signal exceeds 80%, the sensor is still working, but the signal from the sensor is above range.FMI 1 "Data Valid But Below Normal Operating Range" - Every electronic control system sets a low limit for the expected operating range of the signal. A sensor may still be working but is sending a signal below the minimum range.Some possible causes of an FMI 01 are:
The signal is below the normal range
The timing is incorrectThe following is an example of a PWM sensor. This sensor is not expected to generate a PWM signal below a duty cycle of 5% with 0 psi air pressure. A sensor that generates a signal with a duty cycle of 4% at 0 psi will work, but the signal is below range. FMI 01 will be recorded for this condition.FMI 2 "Data Erratic, Intermittent or Incorrect" - The signal from a component is present. The control that reads the diagnostic information cannot read the signal properly. The signal appears to be unstable, or invalid. The data can be intermittent. This condition can relate to communication between controls. The following conditions may cause this code to be recorded:
Failed connection
Intermittent or erratic signal
Changed software
Noisy signal
Out of range signalFMI 3 "Voltage Above Normal or Shorted High" - The component or system voltage is higher than the limit. FMI 03 most often relates to a signal circuit.Some components that could cause an FMI 03 are:
Failed sensor or switch
Damaged harness is
Failed ECMSome possible causes of an FMI 03 are:
A sensor that has failed and the voltage output is high.
Any wiring harness
The codes for the Failure Mode Identifier (FMI) are defined by the Society Of Automotive Engineers Inc. (SAE). The Table 4 contains the CAT definitions for the FMI. Diagram 1 illustrates FMI codes that can be generated from a sensor that has failed.
Illustration 1 g00493694
Range of possible FMI codes generated from a failed sensor
Table 4
Failure Mode Identifier Definitions
FMI Failure Description
0 Data valid but above normal operating range
1 Data valid but below normal operating range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
4 Voltage below normal or shorted low
5 Current below normal or open circuit
6 Current above normal or grounded circuit
7 Mechanical system not responding properly
8 Abnormal frequency, pulse, or period
9 Abnormal update
10 Abnormal rate of change
11 Failure mode not identifiable
12 Bad device or component
13 Out of calibration
14 Special Instruction Detailed FMI Explanation
FMI 0 "Data Valid But Above Normal Operating Range" - Every electronic control system has a high limit setting for the expected operating range of the signal. The high limit includes over range signals. A sensor that is still operating but sending a signal above the expected limit will cause an FMI 00 to be recorded.Some possible causes of an FMI 00 are:
The signal is above normal
The signal is shorted to the +battery circuit
The sensor is out of calibrationThe following is an example of a sensor that needs calibration. A PWM signal with an 80% duty cycle is a valid signal. If the PWM signal exceeds 80%, the sensor is still working, but the signal from the sensor is above range.FMI 1 "Data Valid But Below Normal Operating Range" - Every electronic control system sets a low limit for the expected operating range of the signal. A sensor may still be working but is sending a signal below the minimum range.Some possible causes of an FMI 01 are:
The signal is below the normal range
The timing is incorrectThe following is an example of a PWM sensor. This sensor is not expected to generate a PWM signal below a duty cycle of 5% with 0 psi air pressure. A sensor that generates a signal with a duty cycle of 4% at 0 psi will work, but the signal is below range. FMI 01 will be recorded for this condition.FMI 2 "Data Erratic, Intermittent or Incorrect" - The signal from a component is present. The control that reads the diagnostic information cannot read the signal properly. The signal appears to be unstable, or invalid. The data can be intermittent. This condition can relate to communication between controls. The following conditions may cause this code to be recorded:
Failed connection
Intermittent or erratic signal
Changed software
Noisy signal
Out of range signalFMI 3 "Voltage Above Normal or Shorted High" - The component or system voltage is higher than the limit. FMI 03 most often relates to a signal circuit.Some components that could cause an FMI 03 are:
Failed sensor or switch
Damaged harness is
Failed ECMSome possible causes of an FMI 03 are:
A sensor that has failed and the voltage output is high.
Any wiring harness
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
4I8785
HOSE AS
315B, 315B L, 315C, 315D L, 316E L, 317B LN, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN, 320 L, 320B, 320C, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 32...
315B, 315B L, 315C, 315D L, 316E L, 317B LN, 318D L, 318D2 L, 318E L, 319D, 319D L, 319D LN, 320 L, 320B, 320C, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 32...
1087203
HOSE AS
307C, 308D, 312C, 312C L, 314C, 316E L, 318C, 318E L, 319C, 320B, 320C, 320C L, 320D FM, 320D L, 320D LN, 321C, 321D LCR, 322B, 322B L, 322C, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D ...
307C, 308D, 312C, 312C L, 314C, 316E L, 318C, 318E L, 319C, 320B, 320C, 320C L, 320D FM, 320D L, 320D LN, 321C, 321D LCR, 322B, 322B L, 322C, 323D L, 323D LN, 323D SA, 324D, 324D FM, 324D FM LL, 324D ...
4I0836
HOSE AS
307B, 307C, 308C, 311D LRR, 311F LRR, 312C L, 314C, 314D CR, 314D LCR, 315C, 315D L, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D...
307B, 307C, 308C, 311D LRR, 311F LRR, 312C L, 314C, 314D CR, 314D LCR, 315C, 315D L, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320 L, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D...
0874531
HOSE AS
307C, 311C, 311D LRR, 311F LRR, 312C, 312C L, 312D, 312D L, 312E, 312E L, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L, 316E L, 318C, 318E L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 32...
307C, 311C, 311D LRR, 311F LRR, 312C, 312C L, 312D, 312D L, 312E, 312E L, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L, 316E L, 318C, 318E L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 32...
5I4396
HOSE AS
307C, 308D, 311F LRR, 312D, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318C, 318D2 L, 318E L, 319D, 319D L, 319D LN, 320 L, 320B, 320B L, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 3...
307C, 308D, 311F LRR, 312D, 314D CR, 314D LCR, 314E CR, 314E LCR, 315D L, 316E L, 318C, 318D2 L, 318E L, 319D, 319D L, 319D LN, 320 L, 320B, 320B L, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 3...
1048771
HOSE AS
307C, 308C, 311D LRR, 311F LRR, 312C, 312C L, 314D CR, 314D LCR, 315D L, 316E L, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D FM, 320D LRR, 320D RR, 32...
307C, 308C, 311D LRR, 311F LRR, 312C, 312C L, 314D CR, 314D LCR, 315D L, 316E L, 318C, 318D L, 318D2 L, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D FM, 320D LRR, 320D RR, 32...
0875303
HOSE AS
308C, 312C L, 312D, 312D L, 315C, 315D L, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 322...
308C, 312C L, 312D, 312D L, 315C, 315D L, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 322...
1021157
HOSE AS
314C, 318C, 319C, 320B, 320B U, 320C, 321C, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 322C FM, 323D L, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325B, 325B L, 325C, 325C FM, 325C L, 325D, ...
314C, 318C, 319C, 320B, 320B U, 320C, 321C, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 322C FM, 323D L, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325B, 325B L, 325C, 325C FM, 325C L, 325D, ...
2302866
HOSE
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3...
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, 330D, 330D FM, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN, 336D2, 336D2 L, 3...
2813487
HOSE-RADIATOR
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
2302870
HOSE-RADIATOR
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, M325D L MH, M325D MH
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 328D LCR, 329D, 329D L, 329D LN, M325D L MH, M325D MH
2302865
HOSE
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
3746060
HOSE AS
330D L, 336D, 336D L, 336D2
330D L, 336D, 336D L, 336D2
3746059
HOSE
330D L, 336D, 336D L
330D L, 336D, 336D L
3746058
HOSE AS
330D L, 336D, 336D L, 336D2, 336D2 L, 340D2 L
330D L, 336D, 336D L, 336D2, 336D2 L, 340D2 L
3746057
HOSE AS
330D L, 336D, 336D L, 336D2
330D L, 336D, 336D L, 336D2
3746056
HOSE AS
330D L, 336D, 336D L, 336D2
330D L, 336D, 336D L, 336D2
3432399
HOSE AS
330D, 330D L, 330D MH, 336D, 336D L, 336D LN
330D, 330D L, 330D MH, 336D, 336D L, 336D LN
3719272
HOSE AS
329D L
329D L
3719271
HOSE AS
329D L
329D L
3719270
HOSE AS
329D L
329D L
3719268
HOSE AS
329D L
329D L
3719267
HOSE AS
329D L
329D L
2868145
HOSE AS
325D L, 328D LCR, 329D L
325D L, 328D LCR, 329D L