4196161 HOSE & TUBE AS Caterpillar parts
C175-16
Rating:
Alternative (cross code) number:
CA4196161
419-6161
4196161
CA4196161
419-6161
4196161
Weight: 1 pounds 0 kg.
MARINE ENGINE, PETROLEUM ENGINE,
Compatible equipment models: 4196161:
Information:
Troubleshooting Active Ground Faults
Note: The APC contains two filter capacitors that are used in the ground fault detection system. One filter capacitor is internally connected between the positive ("+") DC Power Bus (contact A) and the housing for the APC (frame ground). The other filter capacitor is internally connected between the negative ("-") DC Power Bus (contact B) and the housing for the APC (frame ground). Some specific conditions that can cause a level 3 ground fault to be activated can also damage the filter capacitors in the APC. A ground fault in the motor windings or a Generator windings could damage the filter capacitors. When the APC is operated with a damaged filter capacitor, the APC will detect a constant ground fault condition when no ground fault condition exists. After a ground fault that is caused by the winding of a motor or the winding of a generator is repaired, the filter capacitors must be tested to detect any damage. If a ground fault has occurred in the windings for the drive motor or in the windings for the Generator, call the Dealer Solution Network (DSN). The DSN will provide further instructions on the procedure to follow to verify the status of the filter capacitors in the APC.Insulation Testing
Illustration 1 g01515993
Handheld Insulation Tester
When a ground fault is present in the AC section of the power train electrical system, the integrity of the isolation material can be tested. An insulation tester will be used to check the degree of insulation resistance between the conductors or the motor windings and frame ground.The Insulation Tester can also be used to check the integrity of the isolation material that is used in the DC section of the system. Using an Insulation Tester on some components in the DC section of the system could damage system control modules if not used correctly. Only use an insulation tester on control modules in the DC section of the system when instructed to in a procedure.When an insulation tester, the positive side probe of the insulation tester is connected to a copper conductor or to a winding connection. The negative side probe of the insulation tester is connected to frame ground, a grounded component housing or, a ground wire. The insulation tester will be used to induce a voltage that is higher than normal into the conductor or winding that is being tested. The insulation tester will measure the voltage potential that is present on the frame of the machine or on a ground wire. The insulation tester will calculate the amount of resistance that is present in the isolation material that is between the two probes.The resistance value that is measured will indicate whether the condition of the insulation that is being tested is in good condition or is not in good condition. When a conductor or a component such as a motor or a generator is tested, a reading of two megohms (two million ohms) or less of resistance between the component conductor or
Note: The APC contains two filter capacitors that are used in the ground fault detection system. One filter capacitor is internally connected between the positive ("+") DC Power Bus (contact A) and the housing for the APC (frame ground). The other filter capacitor is internally connected between the negative ("-") DC Power Bus (contact B) and the housing for the APC (frame ground). Some specific conditions that can cause a level 3 ground fault to be activated can also damage the filter capacitors in the APC. A ground fault in the motor windings or a Generator windings could damage the filter capacitors. When the APC is operated with a damaged filter capacitor, the APC will detect a constant ground fault condition when no ground fault condition exists. After a ground fault that is caused by the winding of a motor or the winding of a generator is repaired, the filter capacitors must be tested to detect any damage. If a ground fault has occurred in the windings for the drive motor or in the windings for the Generator, call the Dealer Solution Network (DSN). The DSN will provide further instructions on the procedure to follow to verify the status of the filter capacitors in the APC.Insulation Testing
Illustration 1 g01515993
Handheld Insulation Tester
When a ground fault is present in the AC section of the power train electrical system, the integrity of the isolation material can be tested. An insulation tester will be used to check the degree of insulation resistance between the conductors or the motor windings and frame ground.The Insulation Tester can also be used to check the integrity of the isolation material that is used in the DC section of the system. Using an Insulation Tester on some components in the DC section of the system could damage system control modules if not used correctly. Only use an insulation tester on control modules in the DC section of the system when instructed to in a procedure.When an insulation tester, the positive side probe of the insulation tester is connected to a copper conductor or to a winding connection. The negative side probe of the insulation tester is connected to frame ground, a grounded component housing or, a ground wire. The insulation tester will be used to induce a voltage that is higher than normal into the conductor or winding that is being tested. The insulation tester will measure the voltage potential that is present on the frame of the machine or on a ground wire. The insulation tester will calculate the amount of resistance that is present in the isolation material that is between the two probes.The resistance value that is measured will indicate whether the condition of the insulation that is being tested is in good condition or is not in good condition. When a conductor or a component such as a motor or a generator is tested, a reading of two megohms (two million ohms) or less of resistance between the component conductor or
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
3358687
HOSE AS
C175-16
C175-16
3771501
HOSE AS
C175-16
C175-16
3897120
HOSE AS
C175-16
C175-16
3712842
HOSE AS
C175-16
C175-16
3712843
HOSE AS
C175-16
C175-16
3462095
HOSE AS
3516C, C175-16, C175-20
3516C, C175-16, C175-20
2451441
HOSE AS
928HZ, 930G, C175-16
928HZ, 930G, C175-16
3239976
HOSE AS
C175-16
C175-16
2972673
HOSE AS
C175-16
C175-16
2972674
HOSE AS
C175-16
C175-16
3155581
HOSE AS
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, C175-16, C175-20
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797B, 797F, C175-16, C175-20
3135517
HOSE AS
C175-16
C175-16
4181262
HOSE AS
793F, 793F CMD, 793F OEM, 795F AC, 795F XQ, 797, 797B, 797F, C175-16
793F, 793F CMD, 793F OEM, 795F AC, 795F XQ, 797, 797B, 797F, C175-16
3758152
HOSE AS
C175-16
C175-16
3270812
HOSE AS
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 797, 797B, 797F, C175-16, C175-20
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 797, 797B, 797F, C175-16, C175-20
3931749
HOSE AS
C175-16
C175-16
4196160
HOSE & TUBE AS
C175-16
C175-16
3836595
HOSE AS
C175-16
C175-16
1458292
HOSE AS
C175-16, CS-563D, CS-663E, CS-683E, PS-150B, PS-150C, PS-200B
C175-16, CS-563D, CS-663E, CS-683E, PS-150B, PS-150C, PS-200B
4231980
HOSE
311F LRR, 637D, 637E, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797F, 966H, 972H, 980C, 980G, AD30, AD45B, C15, C175-16, C175-20, C18, CX31-C13I, D10T2, SPF343C, XQC1200, XQC1600
311F LRR, 637D, 637E, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797F, 966H, 972H, 980C, 980G, AD30, AD45B, C15, C175-16, C175-20, C18, CX31-C13I, D10T2, SPF343C, XQC1200, XQC1600
3198105
HOSE AS
C175-16
C175-16
3025917
HOSE AS
C175-16, C175-20
C175-16, C175-20
3931752
HOSE AS
C175-16
C175-16
3931751
HOSE AS
C175-16
C175-16