4263863 HOSE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4263863
426-3863
4263863
CA4263863
426-3863
4263863
Weight: 3 pounds 1 kg.
Information:
Illustration 1 g00479965
System Schematic For Starting Motor Relay (SMR)The GSC uses the starting motor relay (SMR) to activate the starting motor magnetic switches ("SMMS1" and "SMMS2") and the battery charger. The SMR is located within the relay module. "SMMS1" and "SMMS2" are located on the subpanel within the control panel.Note: Whenever the GSC activates the SMR, "K4" is shown on the lower display. "K4" is also shown on the lower display when the GSC attempts to activate the crank terminate relay. When the SMR is not activated, "K4" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the SMR.The following response is the system response to this fault while the SMR is activated:
If a CID 444 occurs, then the engine stops cranking.The following response is the system response to this fault while the SMR is not activated:
If a CID 444 occurs, then the engine cannot crank or the engine cannot start. If the engine is already running, then the engine continues to run.The GSC treats a CID 444 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 444 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 444 FMI 12 is showing as a active fault or an inactive fault. Results:
No - A CID 444 FMI 12 has not occurred (NOT active and NOT inactive). STOP.
Yes - A CID 444 FMI 12is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK - Reassemble the relay module to the GSC. Proceed to 3.
NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.
Perform a functional check for the SMR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-18
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
4263862
HOSE AS
Caterpillar
Caterpillar
4263861
HOSE
Caterpillar
Caterpillar
4262715
HOSE AS
Caterpillar
Caterpillar
4262713
HOSE AS
Caterpillar
Caterpillar
4262712
HOSE AS
Caterpillar
Caterpillar
4262711
HOSE AS
Caterpillar
Caterpillar
4317761
HOSE AS
Caterpillar
Caterpillar
4309123
HOSE AS
Caterpillar
Caterpillar
4289249
HOSE AS
Caterpillar
Caterpillar
4289248
HOSE AS
Caterpillar
Caterpillar
4264000
HOSE AS
Caterpillar
Caterpillar
4263864
HOSE AS
Caterpillar
Caterpillar