4989720 HOSE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4989720
498-9720
4989720
CA4989720
498-9720
4989720
Weight: 44 pounds 20 kg.
Information:
This diagnostic code is associated with the Auxiliary Third Lever Position Sensor. The position sensor provides a PWM input signal to the Implement ECM. The FMI 13 diagnostic code is activated when the ECM detects a sensor that needs calibration.The sensor is a PWM sensor that operates at a frequency of approximately 500 100 Hz. The duty cycle of the PWM signal that is supplied to the ECM is measured in small increments.Test Step 1. CALIBRATION
Perform the calibration procedure for the sensor. Refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
OK - The calibration procedure was performed successfully. Resume normal machine operationSTOP
NOT OK - The calibration was not successful.Repair: Repeat the calibration procedure for the sensor.If the second calibration procedure is not successful, replace the implement control lever assembly.After sensor replacement, refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct procedure. If the problem is still present after replacement and calibration of the new sensor, the ECM may have failed.Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual for additional information.STOP
Perform the calibration procedure for the sensor. Refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct calibration procedure. Expected Result:The calibration procedure was performed successfully.Results:
OK - The calibration procedure was performed successfully. Resume normal machine operationSTOP
NOT OK - The calibration was not successful.Repair: Repeat the calibration procedure for the sensor.If the second calibration procedure is not successful, replace the implement control lever assembly.After sensor replacement, refer to the Testing and Adjusting, "Calibration" Story in this manual for the correct procedure. If the problem is still present after replacement and calibration of the new sensor, the ECM may have failed.Prior to replacing an ECM, always contact the Technical Communicator at your dealership for possible consultation with Caterpillar. This consultation may effect repair time. If the cause of the diagnostic code is not found, replace the ECM. Refer to the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" Story in this manual for additional information.STOP
Parts hose Caterpillar catalog:
4989118
HOSE
Caterpillar
Caterpillar
4989117
HOSE
Caterpillar
Caterpillar
4988895
HOSE AS
Caterpillar
Caterpillar
4988766
HOSE AS
Caterpillar
Caterpillar
4988512
HOSE AS
Caterpillar
Caterpillar
4988511
HOSE AS
Caterpillar
Caterpillar
4990017
HOSE AS
Caterpillar
Caterpillar
4990016
HOSE AS
Caterpillar
Caterpillar
4990015
HOSE AS
Caterpillar
Caterpillar
4990014
HOSE AS
Caterpillar
Caterpillar
4989866
HOSE-AIR
Caterpillar
Caterpillar
4989807
HOSE AS
Caterpillar
Caterpillar