Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly inspect the connectors between the EFLP relay and the engine ECM. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the EFLP relay.
D. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
E. Check the harness and wiring for abrasion and for pinch points from the injectors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair:Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position. Do not start the engine.
C. Make a note of any active diagnostic codes.
D. Wait for at least 2 minutes for the Electric Fuel Lift Pump (EFLP) to deactivate. Make a note of any active diagnostic codes.
Diagnostic codes
Result: Diagnostic code 1075-5 (3666-5) is active when the EFLP is switched off.
Proceed to Test Step 3.
Result: Diagnostic code 1075-6 (3666-6) is active when the EFLP is switched on.
Proceed to Test Step 5.
Result: An active diagnostic code or a recently logged diagnostic code was not displayed. There may be a fault with the switched power circuit for the EFLP. The ECM does not monitor the status of this condition.
Proceed to Test Step 7.
3. Create a Short Circuit at the EFLP Relay
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the Electric Fuel Lift Pump (EFLP) relay.
C. Fabricate a jumper wire that is 150 mm (6 inch) long.
D. Use the jumper wire to connect Test Point 1 to Test Point 2 on the harness connector for the EFLP relay. Refer to Illustration 1. Refer to the appropriate electrical schematic.
E. Turn the keyswitch to the ON position. Do not start the engine.
F. Use the electronic service tool to check for an active 1075-6 or 3666-6diagnostic code.
G. Wait for at least 2 minutes for the EFLP to deactivate. Check for an active 1075-5 or 3666-5 diagnostic code.
H. Turn the keyswitch to the OFF position.
I. Remove the jumper. Leave the connector for the EFLP disconnected.
Open circuit
Result: A 1075-6 (3666-6) diagnostic code was active with the jumper installed.
Repair: Install a replacement EFLP relay.
Reconnect the connector for the EFLP relay.
Turn the keyswitch to the ON position. Do not start the engine. Check for active diagnostic codes.
Wait for at least 2 minutes for the EFLP to deactivate. Check for active diagnostic codes.
Confirm that the fault
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
4993892
HOSE AS
Caterpillar
Caterpillar
4993891
HOSE AS
Caterpillar
Caterpillar
4993890
HOSE AS
Caterpillar
Caterpillar
4993889
HOSE AS
Caterpillar
Caterpillar
4993888
HOSE AS
Caterpillar
Caterpillar
4993887
HOSE AS
Caterpillar
Caterpillar
5003630
HOSE AS
Caterpillar
Caterpillar
5002605
HOSE AS
Caterpillar
Caterpillar
5002604
HOSE AS
Caterpillar
Caterpillar
5002603
HOSE AS
Caterpillar
Caterpillar
5000535
HOSE AS
Caterpillar
Caterpillar
5000534
HOSE AS
Caterpillar
Caterpillar