4I3817 HOSE AS Caterpillar parts
311F LRR, 320 L, 320N, 349E, 349E L, 349E L HVG, 349E L VG, 349F L
Rating:
Alternative (cross code) number:
CA4I3817
4I-3817
4I3817
CA4I3817
4I-3817
4I3817
Weight: 2 pounds 1 kg.
EXCAVATOR, MOBILE HYD POWER UNIT,
Compatible equipment models: 4I3817:
Caterpillar parts catalog:
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
4368-1
Aftertreatment #1 DEF Tank #2 Temperature : Low - most severe (3) E1399 (3)
Low Aftertreatment #1 DEF Tank #2 Temperature The Diesel Exhaust Fluid (DEF) tank temperature is low.
4368-17
Aftertreatment #1 DEF Tank #2 Temperature : Low - least severe (1) E1399 (1)
Low Aftertreatment #1 DEF Tank #2 Temperature The DEF tank temperature is low.
4368-18
Aftertreatment #1 DEF Tank #2 Temperature : Low - moderate severity (2) E1399 (2)
Low Aftertreatment #1 DEF Tank #2 Temperature The DEF tank temperature is low.
Table 2
Associated Codes
J1939 Code CDL Code Troubleshooting Procedure
4368-3 3135-3 Troubleshooting, "DEF Tank Sensor - Test"
4368-4 3135-4 Troubleshooting, "DEF Tank Sensor - Test" Probable Causes
Codes
SensorRecommended Actions
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Turn the DC breaker, located in the power distribution box, to the ON position.
B. Connect Cat® Electronic Technician (ET) to the service tool connector.
C. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check the DEF Tank #2 Temperature Sensor
A. Turn the DC breaker, located in the power distribution box, to the ON position.
B. Connect Cat ET.
C. Use Cat ET to monitor the following temperature:
- "Cabinet Temperature"
- "DEF Tank #2 Temperature"
Sensor
Result: The "DEF Tank #2 Temperature" is within 5° C (9° F) of the "Cabinet Temperature".
Repair:The DEF Tank temperature is too low. Contact your TC for assistance.
Result: The "DEF Tank #2 Temperature" is not within 5° C (9° F) of the "Cabinet Temperature".
Repair: A failed DEF tank temperature sensor has been detected. Replace the DEF header assembly.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts hose Caterpillar catalog:
4505940
HOSE AS
311F LRR
311F LRR
4222119
HOSE AS
311F LRR
311F LRR
4505937
HOSE AS
311F LRR
311F LRR
4505934
HOSE AS
311F LRR
311F LRR
1849155
HOSE AS
311F LRR, 320E LRR, 320E RR, 322C, 322C FM, 325C, 330C, M325D L MH, M325D MH
311F LRR, 320E LRR, 320E RR, 322C, 322C FM, 325C, 330C, M325D L MH, M325D MH
4506345
HOSE AS
311F LRR
311F LRR
3481334
HOSE AS
311F LRR
311F LRR
3837908
HOSE AS
311F LRR, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E HVG, 336E L, 336E LN, 336F L, 374F L, 568 FM LL
311F LRR, 324E, 324E L, 324E LN, 329E, 329E L, 329E LN, 336E, 336E HVG, 336E L, 336E LN, 336F L, 374F L, 568 FM LL
4213485
HOSE AS-REFRIGERANT
311F LRR
311F LRR
4213484
HOSE AS-REFRIGERANT
311F LRR
311F LRR
4213482
HOSE AS-REFRIGERANT
311F LRR
311F LRR
4236072
HOSE AS
311F LRR
311F LRR