OP8 Setpoints (1) - Voltmeter Ammeter Programming    
Setpoint     Name     Description     Range Of Value     Factory Default    
AC01     Phase A (VA)
Voltage Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the Phase A voltage transformer within the ATB+.     0 to 255 in increments of 1     0    
AC02     Phase B (VB)
Voltage Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the phase B voltage transformer within the ATB+.     0 to 255 in increments of 1     0    
AC03     Phase C (VC)
Voltage Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the phase C voltage transformer within the ATB+.     0 to 255 in increments of 1     0    
AC04     Phase A (IA)
Current Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the phase A current transformer within the ATB+.     0 to 255 in increments of 1     0    
AC05     Phase B (IB)
Current Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the phase B current transformer within the ATB+.     0 to 255 in increments of 1     0    
AC06     Phase C (IC)
Current Calibration     The calibration value is used by the GSC+ in order to compensate for the characteristics of the phase C current transformer within the ATB+.     0 to 255 in increments of 1     0    
( 1 ) The setpoints are programmed at the factory. The setpoints are programmed to the calibration value that is listed on the bar code sticker of the ATB+.OP8 is the option for programming the calibration value of the voltmeter and ammeter. After the GSC+ or the AC transformer box + (ATB+) has been replaced the calibration values must be programmed into the GSC+. The calibration values are found on the bar code sticker of the ATB+. The calibration values are used in order to ensure accurate voltage and current values.The GSC+ monitors six transformers in the ATB+ for information about the voltage and current. Each transformer has individual characteristics that affect the voltage and current measurements that are taken by the GSC+. A calibration value is measured and the value is assigned at the factory. The calibration value is recorded on the bar code sticker that is located on the lower left hand side of the ATB+. When the generator set is assembled at the factory, the calibration values on the bar code sticker are programmed into the GSC+. The transformer's calibration value is 0 to 255. The transformer's calibration value uses increments of 1.Procedure For Voltmeter/Ammeter Programming
Note: Service Mode cannot be entered when the engine control switch (ECS) is in the AUTO position.Note: Any active shutdown fault must
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
5580361
HOSE AS
Caterpillar
Caterpillar
5580360
HOSE AS
Caterpillar
Caterpillar
5580359
HOSE AS
Caterpillar
Caterpillar
5577469
HOSE AS
Caterpillar
Caterpillar
5569116
HOSE AS
Caterpillar
Caterpillar
5569114
HOSE AS
Caterpillar
Caterpillar
5588177
HOSE AS
Caterpillar
Caterpillar
5585405
HOSE AS
Caterpillar
Caterpillar
5582717
HOSE AS
Caterpillar
Caterpillar
5582716
HOSE AS
Caterpillar
Caterpillar
5582713
HOSE AS
Caterpillar
Caterpillar
5580363
HOSE AS
Caterpillar
Caterpillar