Information:
Initial Start-Up
Preparing a generator for parallel operation requires special attention. Before you attempt to parallel units for the first time, check all the units for the following three conditions.
same phase rotation
same alternating current frequency
same voltage adjustment
Check the phase rotation.Units that operate in parallel must have the same phase rotation. There are two methods that may be used in order to determine if the incoming unit and the unit that is on-line have the same phase rotation. These methods are listed below:
using a phase rotation meter
using a set of three light bulbsUse the procedure below to determine the proper phase rotation by using three light bulbs.
Illustration 1 g00695380
When servicing or repairing electric power generation equipment:Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. Remove all fuses.
Connect the light bulbs with rated voltage between the generator leads and the corresponding line phase. For example, connect terminal 1 to line 1 across the open circuit breaker.
Start the units that will be in operating in parallel. Bring the units up to speed. As the units approach the same speed, the lights will start to blink.
If the lights blink in sequence, one of the units is connected backward. In order to correct the problem, stop the units. Remove generator leads 1 and 3 at the circuit breaker. Exchange these generator leads. This reverses the direction of phase rotation. Terminal 2 should always be connected to line 2. Go to 5.
Both generators have the same phase rotation when the lights blink in unison. The first condition of "Initial Start-Up" has been met.
Adjust the frequency.The units that will be operating in parallel must operate at the same speed. Speed is proportional to the alternating current frequency.
Allow each electric set to run under load for about 30 minutes.
Adjust the control in order to give the rated frequency at full load.
Remove the load and check the high idle speed. The high idle speed should be approximately 2 to 5 percent above full load speed for generators that are equipped with droop. If these speeds cannot be obtained, contact your Cat dealer.
For the most consistent results, repeat 2.b and 2.c until the second condition of "Initial Start-Up" has been met.
Adjust the voltage.The potentiometers should be at the initial settings. Refer to Operation and Maintenance Manual, "Voltage Regulators".Note: Make sure that the speed droop is identical for all of the engines before adjustments are made to the generator.
Preset the unit for parallel operation by connecting the current transformer to S1 and S2 of the connector J2. Set potentiometer P1 for quadrature droop in the center position. Apply the rated load. The voltage should drop for 2% to 3%. Switch the positions of the two incoming secondary wires of the current transformer if the voltage increases.
The no-load voltages should be identical for all the generators that are operating in parallel. Connect the generators in parallel. Try to obtain a 0 kW power exchange by adjusting the speed
Preparing a generator for parallel operation requires special attention. Before you attempt to parallel units for the first time, check all the units for the following three conditions.
same phase rotation
same alternating current frequency
same voltage adjustment
Check the phase rotation.Units that operate in parallel must have the same phase rotation. There are two methods that may be used in order to determine if the incoming unit and the unit that is on-line have the same phase rotation. These methods are listed below:
using a phase rotation meter
using a set of three light bulbsUse the procedure below to determine the proper phase rotation by using three light bulbs.
Illustration 1 g00695380
When servicing or repairing electric power generation equipment:Make sure the unit is off-line (disconnected from utility and/or other generators power service), and either locked out or tagged DO NOT OPERATE. Remove all fuses.
Connect the light bulbs with rated voltage between the generator leads and the corresponding line phase. For example, connect terminal 1 to line 1 across the open circuit breaker.
Start the units that will be in operating in parallel. Bring the units up to speed. As the units approach the same speed, the lights will start to blink.
If the lights blink in sequence, one of the units is connected backward. In order to correct the problem, stop the units. Remove generator leads 1 and 3 at the circuit breaker. Exchange these generator leads. This reverses the direction of phase rotation. Terminal 2 should always be connected to line 2. Go to 5.
Both generators have the same phase rotation when the lights blink in unison. The first condition of "Initial Start-Up" has been met.
Adjust the frequency.The units that will be operating in parallel must operate at the same speed. Speed is proportional to the alternating current frequency.
Allow each electric set to run under load for about 30 minutes.
Adjust the control in order to give the rated frequency at full load.
Remove the load and check the high idle speed. The high idle speed should be approximately 2 to 5 percent above full load speed for generators that are equipped with droop. If these speeds cannot be obtained, contact your Cat dealer.
For the most consistent results, repeat 2.b and 2.c until the second condition of "Initial Start-Up" has been met.
Adjust the voltage.The potentiometers should be at the initial settings. Refer to Operation and Maintenance Manual, "Voltage Regulators".Note: Make sure that the speed droop is identical for all of the engines before adjustments are made to the generator.
Preset the unit for parallel operation by connecting the current transformer to S1 and S2 of the connector J2. Set potentiometer P1 for quadrature droop in the center position. Apply the rated load. The voltage should drop for 2% to 3%. Switch the positions of the two incoming secondary wires of the current transformer if the voltage increases.
The no-load voltages should be identical for all the generators that are operating in parallel. Connect the generators in parallel. Try to obtain a 0 kW power exchange by adjusting the speed
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
7G3146
HOSE AS
D10N, D8L, D9L, D9N, D9R
D10N, D8L, D9L, D9N, D9R
2104723
HOSE AS
D10R, D10T, D10T2
D10R, D10T, D10T2
1176418
HOSE AS
D10R, D10T
D10R, D10T
1123837
HOSE AS
120H, 120H ES, 120H NA, 120K, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, D10R
120H, 120H ES, 120H NA, 120K, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, D10R
1345419
HOSE AS
D10R, D10T
D10R, D10T
1345418
HOSE AS
D10R, D10T
D10R, D10T
1243347
HOSE AS
D10R, D10T
D10R, D10T
1243346
HOSE AS
D10R, D10T
D10R, D10T
2222190
HOSE AS
D10N, D10R, D10T
D10N, D10R, D10T
2222194
HOSE AS
D10N, D10R, D10T
D10N, D10R, D10T
7G3147
HOSE AS
D10N, D8L, D9L, D9N
D10N, D8L, D9L, D9N
3T8047
HOSE AS
D10N, D9L
D10N, D9L
8K4070
HOSE ASSEM. (64 in. long)
235, 235B, 235C, 235D, 245, 245B, 245D, 992C
235, 235B, 235C, 235D, 245, 245B, 245D, 992C
4N3641
HOSE ASSEM. (36 in. long)
235, 235B, 992C, D8K
235, 235B, 992C, D8K
8K2775
HOSE ASSEM.
235, 235B, 235C, 235D
235, 235B, 235C, 235D
8K3980
HOSE
235
235
8K4174
HOSE ASSEM. (11 in. long)
225, 992
225, 992
1V1774
HOSE ASSEM. 28 in.(7.11 dm)
235, 235B, 235C, 235D
235, 235B, 235C, 235D
5P1295
HOSE 15.24 cm(6 in.)
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 235, 2...
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 16H, 16H NA, 235, 2...
4K1209
HOSE
183B, 235, 235B, 235C, 768B, 769, 789D, 950K, 962K, 977H, 980B, 993K, D9G
183B, 235, 235B, 235C, 768B, 769, 789D, 950K, 962K, 977H, 980B, 993K, D9G
1V1794
HOSE ASSEM. 35 in. (8.89 dm)
235, 235B, 235C, 235D
235, 235B, 235C, 235D
1V1775
HOSE ASSEM. 33.50 in.(8.51 dm)
235, 235B, 235C, 235D
235, 235B, 235C, 235D
4N4476
HOSE
225, 229, 229D
225, 229, 229D