5P0757 HOSE 39.40 cm(15.51 in.) Caterpillar parts
245, 814, 815, 816, 824B, 930, 950, 966C, 977K, 980B, 983, D3C III, D5, D6C, D7F, D8H, D9G, D9H
Rating:
Alternative (cross code) number:
CA5P0757
5P-0757
5P0757
CA5P0757
5P-0757
5P0757
Weight: 1 pounds 0 kg.
EXCAVATOR, WHEEL LOADER,
Compatible equipment models: 5P0757:
Information:
Shutdown Mode Sequence
A shutdown fault occurs and the GSC+ detects the shutdown fault.
To shut off the fuel, the GSC+ deactivates the fuel control relay (FCR).
In order to prevent the engine from starting, the GSC+ deactivates the run relay (RR), and the GSC+ deactivates the starting motor relay (SMR).
In order to remove the generator load, the GSC+ activates the genset fault relay (GFR). This activates the optional circuit breaker shunt trip coil.Note: The spare output may also be programmed to activate when a shutdown occurs. This output can drive a relay in order to open the circuit breaker, or the output can open a transfer switch. See System Operation, "Spare Input/Output Programming OP6".
The GSC+ activates the air shutoff relay (ASR) for 15 seconds during an emergency stop fault, during an engine overspeed fault, or during an speed sensor fault (CID 190).
When engine speed reaches 0 rpm, the GSC+ deactivates the crank termination relay (CTR). The electronic governor relay (EGR) is deactivated when the engine oil pressure reaches the setpoint P014 for low oil pressure shutdown at idle speed 70 kPa (10 psi).
If engine speed does not decrease by at least 100 rpm within five seconds, the GSC+ activates the ASR for 15 seconds.Note: The ASR would already be activated for an emergency stop fault, engine overspeed fault, or speed sensor fault.
The GSC+ FLASHES the corresponding shutdown indicator. If the fault shutdown indicator is FLASHING, a fault code is shown on the upper display. See Systems Operation, "Fault Description".
If the fault shutdown indicator is the only indicator FLASHING, additional information is available. A fault code is shown on the upper display that better identifies the cause of the shutdown fault. See the Systems Operation, "Fault Description".
The lower display continues to show the engine data.
The relay status indicators show.
K2 (GFR)
K6 (ASR) will show for 15 seconds for an emergency stop fault, engine overspeed fault, or speed sensor fault. K6 (ASR) will also show if engine speed does not decrease at least 100 rpm.
K7 (FCR) - (ETS fuel systems) for 70 seconds after engine speed decreases to 40 rpm and oil pressure decreases to 80 kPa (12 psi). (K7 is not shown for ETR fuel systems.)Engine Start Sequence (After Shutdown)
Correct the shutdown fault. See the System Operation, "Fault Identification".
Turning the engine control switch (ECS) to the OFF/RESET position resets the GSC+. If no shutdown fault is active, the GSC+ returns to normal mode and the engine is able to start.
A shutdown fault occurs and the GSC+ detects the shutdown fault.
To shut off the fuel, the GSC+ deactivates the fuel control relay (FCR).
In order to prevent the engine from starting, the GSC+ deactivates the run relay (RR), and the GSC+ deactivates the starting motor relay (SMR).
In order to remove the generator load, the GSC+ activates the genset fault relay (GFR). This activates the optional circuit breaker shunt trip coil.Note: The spare output may also be programmed to activate when a shutdown occurs. This output can drive a relay in order to open the circuit breaker, or the output can open a transfer switch. See System Operation, "Spare Input/Output Programming OP6".
The GSC+ activates the air shutoff relay (ASR) for 15 seconds during an emergency stop fault, during an engine overspeed fault, or during an speed sensor fault (CID 190).
When engine speed reaches 0 rpm, the GSC+ deactivates the crank termination relay (CTR). The electronic governor relay (EGR) is deactivated when the engine oil pressure reaches the setpoint P014 for low oil pressure shutdown at idle speed 70 kPa (10 psi).
If engine speed does not decrease by at least 100 rpm within five seconds, the GSC+ activates the ASR for 15 seconds.Note: The ASR would already be activated for an emergency stop fault, engine overspeed fault, or speed sensor fault.
The GSC+ FLASHES the corresponding shutdown indicator. If the fault shutdown indicator is FLASHING, a fault code is shown on the upper display. See Systems Operation, "Fault Description".
If the fault shutdown indicator is the only indicator FLASHING, additional information is available. A fault code is shown on the upper display that better identifies the cause of the shutdown fault. See the Systems Operation, "Fault Description".
The lower display continues to show the engine data.
The relay status indicators show.
K2 (GFR)
K6 (ASR) will show for 15 seconds for an emergency stop fault, engine overspeed fault, or speed sensor fault. K6 (ASR) will also show if engine speed does not decrease at least 100 rpm.
K7 (FCR) - (ETS fuel systems) for 70 seconds after engine speed decreases to 40 rpm and oil pressure decreases to 80 kPa (12 psi). (K7 is not shown for ETR fuel systems.)Engine Start Sequence (After Shutdown)
Correct the shutdown fault. See the System Operation, "Fault Identification".
Turning the engine control switch (ECS) to the OFF/RESET position resets the GSC+. If no shutdown fault is active, the GSC+ returns to normal mode and the engine is able to start.
Cat SIS web machinery list:
Parts hose Caterpillar catalog:
9L5158
HOSE AS-END
1674, 16G, 245, 3306C, 3406, 3406B, 3406E, 3408, 3408C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 578, 583R, 587R, 589, 621B, 65C, 768C, 769C, 771C, 824C, 834B, 836, 980C, 988B, 988F, CG137-12, D44...
1674, 16G, 245, 3306C, 3406, 3406B, 3406E, 3408, 3408C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 578, 583R, 587R, 589, 621B, 65C, 768C, 769C, 771C, 824C, 834B, 836, 980C, 988B, 988F, CG137-12, D44...
2V5956
HOSE AS
215, 215B, 3126, 3126B, 3126E, 3208, 3304, 3306, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 834B, ...
215, 215B, 3126, 3126B, 3126E, 3208, 3304, 3306, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, 834B, ...
5S5063
HOSE-FLOW
120G, 130G, 140B, 14E, 3306, 815, 816, 966C, D10R, D10T, D9R
120G, 130G, 140B, 14E, 3306, 815, 816, 966C, D10R, D10T, D9R
5P1254
HOSE
3116, 815B, 834B, 834G, 834H, 836G, 836H, 844, 844H, 930, 936, 936F, 950B, 966D, 966F, 966F II, 970F, 972G, 988B, 988G, 988H, 990, 990 II, 990H, 992C, 992D, D4E, D5B, D6D, D7H, G3408, G3408C, G3412C, ...
3116, 815B, 834B, 834G, 834H, 836G, 836H, 844, 844H, 930, 936, 936F, 950B, 966D, 966F, 966F II, 970F, 972G, 988B, 988G, 988H, 990, 990 II, 990H, 992C, 992D, D4E, D5B, D6D, D7H, G3408, G3408C, G3412C, ...
5P0202
HOSE
225, 227, 235, 235C, 245, 245B, 320B, 320B FM LL, 320B L, 320C, 322B, 322B L, 325B, 325B L, 330, 330 L, 330B, 330B L, 345B L, 350, 375, 992C, R1700 II, R1700G, R2900, R2900G
225, 227, 235, 235C, 245, 245B, 320B, 320B FM LL, 320B L, 320C, 322B, 322B L, 325B, 325B L, 330, 330 L, 330B, 330B L, 345B L, 350, 375, 992C, R1700 II, R1700G, R2900, R2900G
6P1090
HOSE AS
D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL
D6C, D6D, D6E, D6G, D6G2 LGP, D6G2 XL
3P5725
HOSE ASSEM.
571G, 572G, D7F, D7G, D7G2
571G, 572G, D7F, D7G, D7G2
9K8141
HOSE AS
518, 528, 528B, 530B, 613B, 613C, 613C II, 615C, 920, 930, 930R, FB518
518, 528, 528B, 530B, 613B, 613C, 613C II, 615C, 920, 930, 930R, FB518
3P5345
HOSE ASSEM.
193, D9H
193, D9H
2V8646
HOSE ASSEM.
245, 245B, 245D
245, 245B, 245D
2V8647
HOSE ASSEM.
245, 245B, 245D
245, 245B, 245D
5C5137
HOSE ASSEM.
215, 215B
215, 215B
5C5139
HOSE ASSEM. 1.18 m(46.46 in.)
215, 225
215, 225
6P1300
HOSE
225, 235, 627B, 637D, D7G, D8K
225, 235, 627B, 637D, D7G, D8K
5C4137
HOSE ASSEM.
215, 215B
215, 215B
9K9483
HOSE ASSEM. 54 in.(13.72 dm)
235, 235B, 235C
235, 235B, 235C