6Y5440 HOSE AS Caterpillar parts
D8N, D8R
Rating:
Alternative (cross code) number:
CA6Y5440
6Y-5440
6Y5440
CA6Y5440
6Y-5440
6Y5440
Weight: 1 pounds 0 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$97.72
15 Apr 2018
300 Hundredths Pounds
CTP: CTP
6Y5440 Hose A Fits Caterpillar 8A 8 D8N D8R 57H
Warranty
Warranty
Information:
D311, D320, D330, D333, D342, D343, D353, D379, D398 Engines Equipped With SRSE GeneratorsSUPPLEMENT: 08/10/81SERVICE MAGAZINE, MARCH 9, 1981, PAGES 6 AND 7.In the article, "Test Procedure For Exciter Reactors On SRSE Generators" that starts on Page 6, the voltages shown on the second line of the "Voltage Test Chart" on Page 7 are not correct. Change the voltages for the 5L7024 and 5L7039 Reactors to read: X2, 59.8-66.2; Y2, 95.0-105.0; Z2, 2.46-2.74.--------------- END SUPPLEMENT ---------------SUPPLEMENT: 05/04/81SERVICE MAGAZINE, MARCH 9, 1981, PAGES 6 AND 7.In the article, "Test Procedure For Exciter Reactors On SRSE Generators" that starts on Page 6, a correction is needed to the last paragraph of the article on Page 7 (Connection "Z2" is wrongly shown as "Z3"). Under "Exciter Reactor Winding Test", change Step 4 to read: 4. Check the X2, Y2, and Z2 voltages found in Step 2 with the respective X2, Y2, and Z2 voltages shown in the chart, or the corrected voltages if corrections were made in Step 3. Each of these voltages must be in the range shown for the specific winding and reactor.
--------------- END SUPPLEMENT ---------------A test procedure is now available to easily check the exciter reactor during troubleshooting of Statically Regulated-Statically Excited (SRSE) generators. The procedure that follows will permit checks of the exciter reactor polarity and the condition of the windings. To make the tests, AC (alternating current) and DC (direct current) voltmeters are needed. The 6V3030 Digital Multimeter Group can be used, or other voltmeters which have the necessary range, including panel types with a dial face and needle.
Exciter Reactor Polarity Test
1. Connect a 6 or 12 volt battery and switch to the H1 and H3 terminals, and a DC voltmeter to the X1 and X2 terminals as shown in Illustration 1. Be sure the positive (+) and negative (-) connections are correct, as shown.
Illustration 1. Connections for exciter reactor polarity test.2. Adjust the voltmeter to a 10 or 20 volt scale first. For some reactor windings, it will be necessary to use a lower voltage scale to get an indication.3. Look at the voltmeter and move the switch to the "ON" position. The desired indication is a positive (+) voltage on the digital multimeter, or a needle movement up the scale on a dial face voltmeter. The indication will be only temporary, and the meter will go back to zero.4. After two seconds or more, move the switch to the "OFF" position. The desired indication is a negative (-) voltage on the digital multimeter, or a needle movement down the scale (below the zero) on a dial face voltmeter. This indication, like the one in Step 3, will be only temporary, and the meter will go back to zero. Do not move the switch to either the "ON" or "OFF" position at intervals of less than two seconds minimum. Shorter intervals will not permit stability in the flow of current.5. Do Steps 3 and 4 again
--------------- END SUPPLEMENT ---------------A test procedure is now available to easily check the exciter reactor during troubleshooting of Statically Regulated-Statically Excited (SRSE) generators. The procedure that follows will permit checks of the exciter reactor polarity and the condition of the windings. To make the tests, AC (alternating current) and DC (direct current) voltmeters are needed. The 6V3030 Digital Multimeter Group can be used, or other voltmeters which have the necessary range, including panel types with a dial face and needle.
Exciter Reactor Polarity Test
1. Connect a 6 or 12 volt battery and switch to the H1 and H3 terminals, and a DC voltmeter to the X1 and X2 terminals as shown in Illustration 1. Be sure the positive (+) and negative (-) connections are correct, as shown.
Illustration 1. Connections for exciter reactor polarity test.2. Adjust the voltmeter to a 10 or 20 volt scale first. For some reactor windings, it will be necessary to use a lower voltage scale to get an indication.3. Look at the voltmeter and move the switch to the "ON" position. The desired indication is a positive (+) voltage on the digital multimeter, or a needle movement up the scale on a dial face voltmeter. The indication will be only temporary, and the meter will go back to zero.4. After two seconds or more, move the switch to the "OFF" position. The desired indication is a negative (-) voltage on the digital multimeter, or a needle movement down the scale (below the zero) on a dial face voltmeter. This indication, like the one in Step 3, will be only temporary, and the meter will go back to zero. Do not move the switch to either the "ON" or "OFF" position at intervals of less than two seconds minimum. Shorter intervals will not permit stability in the flow of current.5. Do Steps 3 and 4 again
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
5P1255
HOSE
120M, 12H NA, 12M, 140H, 140M, 141, 143H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160M, 163H NA, 1673C, 16G, 16H NA, 235B, 245, 245B, 24H, 320B, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, ...
120M, 12H NA, 12M, 140H, 140M, 141, 143H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160M, 163H NA, 1673C, 16G, 16H NA, 235B, 245, 245B, 24H, 320B, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, ...
1007443
HOSE AS
414E, 416B, 416C, 416D, 416E, 420D, 422E, 424D, 426B, 426C, 428, 428B, 428C, 428D, 430D, 436C, 438B, 438C, D8R
414E, 416B, 416C, 416D, 416E, 420D, 422E, 424D, 426B, 426C, 428, 428B, 428C, 428D, 430D, 436C, 438B, 438C, D8R
8C3681
HOSE
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16H, 16H NA, 225D, 231D, 236D, 242D, 2...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16H, 16H NA, 225D, 231D, 236D, 242D, 2...
1226869
HOSE-HYDRAULIC
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 267, 267B, 268B, 272C,...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 267, 267B, 268B, 272C,...
1226870
HOSE-HYDRAULIC
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 3508, 3512, 3516, 3516C, 550B, 560B, 621B, 627F, 631D, 631E, 637D, 637E, 657E, 785D, 793F, 793F AC, 793F CMD...
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 3508, 3512, 3516, 3516C, 550B, 560B, 621B, 627F, 631D, 631E, 637D, 637E, 657E, 785D, 793F, 793F AC, 793F CMD...
4T6224
HOSE AS
D7H, D7R, D7R II, D7R XR, D8N
D7H, D7R, D7R II, D7R XR, D8N
6Y4061
HOSE AS
D8N, D8R, D8R II
D8N, D8R, D8R II
8W0209
HOSE AS
120G, 12G, 130G, 140G, 160G, D8N, D8R
120G, 12G, 130G, 140G, 160G, D8N, D8R
8E5561
HOSE AS
D8N, D8R
D8N, D8R
6Y4049
HOSE AS
D8N, D8R
D8N, D8R
1800929
HOSE AS
992G, D8R, D8R II, D8T
992G, D8R, D8R II, D8T
1895606
HOSE AS
D8R
D8R
6Y4050
HOSE AS
D8N, D8R
D8N, D8R
6Y4062
HOSE AS
D8N, D8R
D8N, D8R
6Y4045
HOSE AS
938F, 938G, 938G II, AP-650B, BG-225C, BG-260D, D8N, D8R, IT38F, IT38G, IT38G II
938F, 938G, 938G II, AP-650B, BG-225C, BG-260D, D8N, D8R, IT38F, IT38G, IT38G II
8E2370
HOSE AS
552, 928F, D8N, D8R, IT28F, TK752
552, 928F, D8N, D8R, IT28F, TK752
0920759
HOSE AS
5130, D8N, D8R
5130, D8N, D8R
8Y9286
HOSE AS
953B
953B
1078437
HOSE AS
D8N
D8N
1054189
HOSE AS
D8N, D8R
D8N, D8R
1054188
HOSE AS
D8N
D8N
1054187
HOSE AS
D8N
D8N
9W4280
HOSE AS
D8N, D9N
D8N, D9N