8D5246 HOSE ASSEM. (24.80 in. long overall) Caterpillar parts
772
Rating:
Alternative (cross code) number:
CA8D5246
8D-5246
8D5246
CA8D5246
8D-5246
8D5246
Weight: 3 pounds 1 kg.
TRACTOR,
Compatible equipment models: 8D5246:
Information:
Power Train ECM
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the sensor power supply circuits of the machine.
Table 2
Power Train ECM (MID 264)
DTC Description System Response
41 - 3 8 V Supply: Voltage Above Normal Sensors powered by the 8 V supply will not function properly.
41 - 4 8 V Supply: Voltage Below Normal Sensors powered by the 8 V supply will not function properly.
1482 - 3 10 V Supply: Voltage Above Normal Sensors powered by the 10 V supply will not function properly.
1482 - 4 10 V Supply: Voltage Below Normal Sensors powered by the 10 V supply will not function properly. The diagnostic code is recorded when the interface module indicates that the voltage of the sensor supply circuit is too high, too low, or erratic.Possible causes of an FMI 3 Diagnostic code are:
The output of the sensor supply has shorted to the + battery circuit.
The ECM has failed. An ECM failure is unlikelyPossible causes of an FMI 4 Diagnostic code are:
The output of sensor supply has an open circuit.
A sensor has failed.
The ECM has failed. An ECM failure is unlikely.
Illustration 3 g03360056
Schematic of the Power Train 8 VDC Sensor Supply Voltage
Illustration 4 g03360134
Schematic of the Power Train 10 VDC Sensor Supply Voltage
Note: The diagrams above are a simplified schematic of the Power Train ECM connections. The diagrams are electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of the Electrical Schematic, KENR5639 for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure. For sensors powered via the fuse panel, check the condition of the appropriate fuse before beginning the troubleshooting procedure.
Table 3
Troubleshooting Test Steps Values Results
1. Identify The Active FMI Code Associated With The Sensor Supply Circuit Code present FMI 3 diagnostic code proceed to Test Step 2.
FMI 4 diagnostic code proceed to Test Step 4.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Voltage At The ECM
A. Turn the key start switch and the battery disconnect switch to the OFF position.
B. At the machine harness connector for the ECM, insert a 7X-1710 Multimeter Probe along the contact for the sensor power. Insert another probe along the return contact for the sensor power.
C. Turn the disconnect switch to the ON position.
D. Observe the voltage measurement for the multimeter and wiggle the machine harness connectors of the ECM. Gently pull on the wires and move the wires around.
See the schematic to determine the voltage that is applicable to each circuit. OK - The voltage is appropriate for the circuit as determined by the schematic.
Proceed to Test Step 3.
NOT OK -
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the sensor power supply circuits of the machine.
Table 2
Power Train ECM (MID 264)
DTC Description System Response
41 - 3 8 V Supply: Voltage Above Normal Sensors powered by the 8 V supply will not function properly.
41 - 4 8 V Supply: Voltage Below Normal Sensors powered by the 8 V supply will not function properly.
1482 - 3 10 V Supply: Voltage Above Normal Sensors powered by the 10 V supply will not function properly.
1482 - 4 10 V Supply: Voltage Below Normal Sensors powered by the 10 V supply will not function properly. The diagnostic code is recorded when the interface module indicates that the voltage of the sensor supply circuit is too high, too low, or erratic.Possible causes of an FMI 3 Diagnostic code are:
The output of the sensor supply has shorted to the + battery circuit.
The ECM has failed. An ECM failure is unlikelyPossible causes of an FMI 4 Diagnostic code are:
The output of sensor supply has an open circuit.
A sensor has failed.
The ECM has failed. An ECM failure is unlikely.
Illustration 3 g03360056
Schematic of the Power Train 8 VDC Sensor Supply Voltage
Illustration 4 g03360134
Schematic of the Power Train 10 VDC Sensor Supply Voltage
Note: The diagrams above are a simplified schematic of the Power Train ECM connections. The diagrams are electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of the Electrical Schematic, KENR5639 for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure. For sensors powered via the fuse panel, check the condition of the appropriate fuse before beginning the troubleshooting procedure.
Table 3
Troubleshooting Test Steps Values Results
1. Identify The Active FMI Code Associated With The Sensor Supply Circuit Code present FMI 3 diagnostic code proceed to Test Step 2.
FMI 4 diagnostic code proceed to Test Step 4.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Voltage At The ECM
A. Turn the key start switch and the battery disconnect switch to the OFF position.
B. At the machine harness connector for the ECM, insert a 7X-1710 Multimeter Probe along the contact for the sensor power. Insert another probe along the return contact for the sensor power.
C. Turn the disconnect switch to the ON position.
D. Observe the voltage measurement for the multimeter and wiggle the machine harness connectors of the ECM. Gently pull on the wires and move the wires around.
See the schematic to determine the voltage that is applicable to each circuit. OK - The voltage is appropriate for the circuit as determined by the schematic.
Proceed to Test Step 3.
NOT OK -
Caterpillar parts catalog:
Parts hose Caterpillar catalog:
5P0763
HOSE
120H, 120H ES, 120H NA, 12G, 12H, 12H NA, 135H, 135H NA, 225, 225D, 227, 229, 229D, 231D, 235, 235B, 235C, 235D, 3114, 3116, 3126, 3126B, 320 L, 3208, 320B, 322B L, 322B LN, 322C, 322C FM, 325, 325 L,...
120H, 120H ES, 120H NA, 12G, 12H, 12H NA, 135H, 135H NA, 225, 225D, 227, 229, 229D, 231D, 235, 235B, 235C, 235D, 3114, 3116, 3126, 3126B, 320 L, 3208, 320B, 322B L, 322B LN, 322C, 322C FM, 325, 325 L,...
5P1255
HOSE
120M, 12H NA, 12M, 140H, 140M, 141, 143H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160M, 163H NA, 1673C, 16G, 16H NA, 235B, 245, 245B, 24H, 320B, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, ...
120M, 12H NA, 12M, 140H, 140M, 141, 143H, 14H NA, 14M, 160H, 160H ES, 160H NA, 160M, 163H NA, 1673C, 16G, 16H NA, 235B, 245, 245B, 24H, 320B, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, ...
5P1257
HOSE
12H NA, 140G, 140H, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235B, 245, 3116, 3126, 3126B, 3208, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, 3408, 3412, 525, 527,...
12H NA, 140G, 140H, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235B, 245, 3116, 3126, 3126B, 3208, 330, 330 L, 3304, 3304B, 3306, 3306B, 330B, 330B L, 3406, 3408, 3412, 525, 527,...
5P0767
HOSE
1090, 1190, 1190T, 120G, 1290T, 1390, 140G, 215, 215B, 215C, 215D, 225, 225D, 227, 229, 2290, 229D, 231D, 235, 235B, 235C, 235D, 236D, 2384C, 2390, 2391, 242D, 245, 245B, 245D, 246D, 2470C, 2484C, 249...
1090, 1190, 1190T, 120G, 1290T, 1390, 140G, 215, 215B, 215C, 215D, 225, 225D, 227, 229, 2290, 229D, 231D, 235, 235B, 235C, 235D, 236D, 2384C, 2390, 2391, 242D, 245, 245B, 245D, 246D, 2470C, 2484C, 249...
5P1265
HOSE
120G, 12G, 130G, 140G, 14G, 14M, 160G, 16G, 16H NA, 224, 245, 245B, 245D, 3208, 3304, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3456, 5130, 5130B, 5230B, 578, 583R, 587R, 611, 615, 615C, 621B, 621E, 621...
120G, 12G, 130G, 140G, 14G, 14M, 160G, 16G, 16H NA, 224, 245, 245B, 245D, 3208, 3304, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3456, 5130, 5130B, 5230B, 578, 583R, 587R, 611, 615, 615C, 621B, 621E, 621...
5P6412
HOSE
1090, 1190, 1190T, 1290T, 1390, 14H, 14H NA, 153, 16H, 16H NA, 2290, 2390, 2391, 2491, 2590, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 511, 521, 522, 532, 541, 541 2, 551, 552, 55...
1090, 1190, 1190T, 1290T, 1390, 14H, 14H NA, 153, 16H, 16H NA, 2290, 2390, 2391, 2491, 2590, 345B, 345B II, 345B II MH, 345B L, 365B, 365B II, 365B L, 480, 511, 521, 522, 532, 541, 541 2, 551, 552, 55...
5P1252
HOSE
120G, 140, 141, 14H, 213B, 214B, 224B, 3304B, 3306, 3306B, 627B, 627E, 627F, 627G, 637D, 637E, 637G, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773E, 773F, 773G, 773G LRC, 773G OEM, 775E, 7...
120G, 140, 141, 14H, 213B, 214B, 224B, 3304B, 3306, 3306B, 627B, 627E, 627F, 627G, 637D, 637E, 637G, 769D, 770, 770G, 770G OEM, 771D, 772, 772G, 772G OEM, 773E, 773F, 773G, 773G LRC, 773G OEM, 775E, 7...
7X7893
HOSE
235D, 3406, 3406B, 3406C, 770, 770G, 772, 772G, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 797B, 797F, 814F, 814F II, 815F, 815F II, 816F, 816F II, 834G, 8...
235D, 3406, 3406B, 3406C, 770, 770G, 772, 772G, 773D, 773E, 773F, 773G, 773G LRC, 773G OEM, 775D, 775E, 775F, 775G, 775G LRC, 775G OEM, 797B, 797F, 814F, 814F II, 815F, 815F II, 816F, 816F II, 834G, 8...
5P1293
HOSE
120G, 120H, 120H ES, 120H NA, 12G, 130G, 135H, 135H NA, 14H, 16H, 16M, 2384C, 2484C, 322 FM L, 325 L, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 5130, 5130B, 521B, 522B, 559C, 579C, 61...
120G, 120H, 120H ES, 120H NA, 12G, 130G, 135H, 135H NA, 14H, 16H, 16M, 2384C, 2484C, 322 FM L, 325 L, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 5130, 5130B, 521B, 522B, 559C, 579C, 61...
2423360
HOSE
120K, 120K 2, 12K, 12M, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 3126, 3126B, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL...
120K, 120K 2, 12K, 12M, 140G, 140K, 140K 2, 140M, 140M 2, 160K, 160M, 160M 2, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 3126, 3126B, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL...
5P1292
HOSE
140, 141, 153, 163, 225, 517, 518, 518C, 527, 528, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 770, 772, 773G, 773G LRC, 773G OEM, 775G, 775G LRC, 775G OEM, 777G, 834, 953D, 988, 9...
140, 141, 153, 163, 225, 517, 518, 518C, 527, 528, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637D, 637E, 637G, 770, 772, 773G, 773G LRC, 773G OEM, 775G, 775G LRC, 775G OEM, 777G, 834, 953D, 988, 9...
1862002
HOSE
583T, 587T, 621B, 621G, 621H, 621K, 623G, 623H, 623K, 627F, 627G, 627H, 627K, 631D, 631E, 631G, 633E II, 637D, 637E, 637G, 651B, 657E, 657G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773E, 773F, 773G,...
583T, 587T, 621B, 621G, 621H, 621K, 623G, 623H, 623K, 627F, 627G, 627H, 627K, 631D, 631E, 631G, 633E II, 637D, 637E, 637G, 651B, 657E, 657G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773E, 773F, 773G,...
8D9623
HOSE ASSEM.
768B, 769
768B, 769
8D9622
HOSE ASSEM.
768B
768B
8D9621
HOSE ASSEM.
768B
768B
8D6526
HOSE ASSEM. (23 in. long)
769C, 772, 773, 773B
769C, 772, 773, 773B
8D6523
HOSE ASSEM. (18 in. long)
769C, 772, 773, 773B
769C, 772, 773, 773B