1107451 HOUSING Caterpillar parts
Rating:
Alternative (cross code) number:
CA1107451
110-7451
1107451
CA1107451
110-7451
1107451
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Information:
Illustration 9 g00301843
Operator monitor panel (right console) (1) Controller display (2) Button for boom priority mode (3) Button for swing priority mode (4) Button for fine control mode (5) Button for user mode (6) Travel alarm cancel switch (7) Power mode switch
Start Service Mode and maintain power shift pressure at 2450 50 kPa (355 7 psi) .
Depress the following three buttons on the operator monitor panel at the same time: button for fine control (4), button for user mode (5) and travel alarm cancel switch (6) . Hold all three buttons down for at least three seconds.
The controller display (1) will be "00 00 00" .
Input the service code "0E 32 3A". To increase the flashing character, push the button for boom priority mode (2) . To decrease the flashing character, push the button for swing priority mode (3) . To move the flashing character to the right, push the button for fine control mode (4) . To move the flashing character to the left, push the button for user mode (5) .
Once the service code is entered into the controller display (1) , depress the following three buttons on the operator monitor panel at the same time: button for fine control (4), button for user mode (5) and travel alarm cancel switch. Hold all three buttons down for at least three seconds.
The controller display (1) will change to "10 -- 1" .Note: If more than ten seconds pass between pushing the buttons, the controller display (1) will revert to the operation mode.
On the operator monitor panel, enter a fixed power shift pressure of 2450 50 kPa (355 7 psi) on the controller display (1) . Adjust controller display (1) in order to attain a power shift pressure of 2450 50 kPa (355 7 psi) on the pressure gauge at pressure tap (15) .
Move the flashing character to the far left. Increase the "1" to a "6" .
Move the flashing character to the right and increase the "0" to a "6" .
The last four characters on the controller display (1) will begin flashing. These characters represent the power shift pressure (kPa). Adjust the last four characters to "2450". To increase the power shift pressure 10 kPa (1.5 psi), push the button for boom priority mode (2) . To decrease the power shift pressure 10 kPa (1.5 psi), push the button for swing priority mode (3) . To increase the power shift pressure 200 kPa (29 psi), push the button for boom priority mode (2) and power mode switch (7) at the same time. To decrease the power shift pressure 200 kPa (29 psi), push the button for swing priority mode (3) and power mode switch (7) at the same time.Note: Always monitor the actual power shift pressure on pressure gauge (10) at pressure tap (15) . The actual power shift pressure must be 2450 50 kPa (355 7 psi) on the
Parts housing Caterpillar catalog:
1106099
HOUSING-
Caterpillar
Caterpillar
1105420
HOUSING-CENTER
Caterpillar
Caterpillar
1104300
HOUSING GP
Caterpillar
Caterpillar
1102134
HOUSING-CLUTCH
Caterpillar
Caterpillar
1100554
HOUSING-AXLE
Caterpillar
Caterpillar
1100048
HOUSING GP-
Caterpillar
Caterpillar
1114350
HOUSING AS-
Caterpillar
Caterpillar
1112834
HOUSING,FRON
Caterpillar
Caterpillar
1112673
HOUSING AS-FLY
Caterpillar
Caterpillar
1110595
HOUSING-
Caterpillar
Caterpillar
1108763
HOUSING
Caterpillar
Caterpillar
1107570
HOUSING-COMPR
Caterpillar
Caterpillar