Introduction
SR4 Generator (Partial View)
(1) VR3F regulator. (2) Terminal box. (3) Droop rheostat location.This manual covers the VR3F regulator used on the permanent magnet (PM) excited SR4 generator. This manual must be used in conjunction with service manual Electric Set Generators SENR7958 and Operation And Maintenance Manual SEBU6150. Follow all safety procedures and warnings in the above generator manuals.VR3F regulator (1) is located in generator terminal box (2).Operation
VR3F Regulator
(4) Terminal strip (for attachments). (5) Rheostat (voltage level). (6) Fuse holder. (7) Terminal strip (for sensing and power). (8) Fuse cover. (9) Fuses. (10) Jumper (for selecting 1x1 or 2x1 slope). (11) Jumper (for selecting 50 Hz or 60 Hz operation). (12) Fuses (PM stator fuses).The purpose of the VR3F regulator is to keep generator output voltage at a rated value. There is one control on the VR3F that is standard. * Voltage level rheostat (5) provides a no load voltage adjustment of approximately +10 to -25%.Additional features built into the VR3F are: * Jumper (10) provides a means of selecting a 1x V/Hz or a 2x V/Hz slope. The 2x V/Hz slope will help the generator set pick up a full block load. 2x V/Hz operation is selected by removing jumper (10).* Jumper (11) provides a means of selecting a 50 Hz or 60 Hz operating frequency. Remove jumper (11) for 50 Hz frequency operation.Rheostat (5) is multiple turn. It does not have a fixed stop at the end of travel, but has an override ratchet.
SR4 Generator Schematic (Permanent Magnet Excited)
(1) VR3F regulator. (13) Lines (3-phase output voltage). (14) Lines (sensing voltage). (15) Lines (VDC excitation voltage). (16) Main stator. (17) Main rotor. (18) Exciter stator. (19) Exciter rotor. (20) PM stator. (21) Permanent magnet. (22) Lines [AC power to (1)].VR3F regulator (1) uses all three phases to sense generator output voltage. Lines (14) function as sensing lines. Lines (14) connect generator output lines (13) to VR3F regulator (1) at terminals 20, 22 and 24 (AC input) on fuses (9) and terminal strip (7). The VR3F regulates voltage based on 1x volts per hertz or 2x volts per hertz. The VR3F offers an approximate 8 volts per hertz (1x) or 16 volts per hertz (2x) characteristic on 480V generators.Lines (22) are used to provide three phase AC power for excitation to the VR3F regulator. Through permanent magnet (21) and stator (20), three phase AC power for excitation voltage is generated. Regulator (1) rectifies the three phase AC voltage to DC voltage. Regulator (1) controls the DC excitation voltage based on the level of the sensing voltage on lines (14). The DC excitation voltage passes through lines (15) to exciter stator (18).In-line fuses (12) limit the field current in the case of an internal short circuit or loss of sensing signal.Fuses (9) are used to protect the VR3F from internal faults and exciter faults. To ensure proper generator operation, the VR3F regulator must be connected as shown in this manual; T1 or T7 to 22, T2 or T8 to
SR4 Generator (Partial View)
(1) VR3F regulator. (2) Terminal box. (3) Droop rheostat location.This manual covers the VR3F regulator used on the permanent magnet (PM) excited SR4 generator. This manual must be used in conjunction with service manual Electric Set Generators SENR7958 and Operation And Maintenance Manual SEBU6150. Follow all safety procedures and warnings in the above generator manuals.VR3F regulator (1) is located in generator terminal box (2).Operation
VR3F Regulator
(4) Terminal strip (for attachments). (5) Rheostat (voltage level). (6) Fuse holder. (7) Terminal strip (for sensing and power). (8) Fuse cover. (9) Fuses. (10) Jumper (for selecting 1x1 or 2x1 slope). (11) Jumper (for selecting 50 Hz or 60 Hz operation). (12) Fuses (PM stator fuses).The purpose of the VR3F regulator is to keep generator output voltage at a rated value. There is one control on the VR3F that is standard. * Voltage level rheostat (5) provides a no load voltage adjustment of approximately +10 to -25%.Additional features built into the VR3F are: * Jumper (10) provides a means of selecting a 1x V/Hz or a 2x V/Hz slope. The 2x V/Hz slope will help the generator set pick up a full block load. 2x V/Hz operation is selected by removing jumper (10).* Jumper (11) provides a means of selecting a 50 Hz or 60 Hz operating frequency. Remove jumper (11) for 50 Hz frequency operation.Rheostat (5) is multiple turn. It does not have a fixed stop at the end of travel, but has an override ratchet.
SR4 Generator Schematic (Permanent Magnet Excited)
(1) VR3F regulator. (13) Lines (3-phase output voltage). (14) Lines (sensing voltage). (15) Lines (VDC excitation voltage). (16) Main stator. (17) Main rotor. (18) Exciter stator. (19) Exciter rotor. (20) PM stator. (21) Permanent magnet. (22) Lines [AC power to (1)].VR3F regulator (1) uses all three phases to sense generator output voltage. Lines (14) function as sensing lines. Lines (14) connect generator output lines (13) to VR3F regulator (1) at terminals 20, 22 and 24 (AC input) on fuses (9) and terminal strip (7). The VR3F regulates voltage based on 1x volts per hertz or 2x volts per hertz. The VR3F offers an approximate 8 volts per hertz (1x) or 16 volts per hertz (2x) characteristic on 480V generators.Lines (22) are used to provide three phase AC power for excitation to the VR3F regulator. Through permanent magnet (21) and stator (20), three phase AC power for excitation voltage is generated. Regulator (1) rectifies the three phase AC voltage to DC voltage. Regulator (1) controls the DC excitation voltage based on the level of the sensing voltage on lines (14). The DC excitation voltage passes through lines (15) to exciter stator (18).In-line fuses (12) limit the field current in the case of an internal short circuit or loss of sensing signal.Fuses (9) are used to protect the VR3F from internal faults and exciter faults. To ensure proper generator operation, the VR3F regulator must be connected as shown in this manual; T1 or T7 to 22, T2 or T8 to
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
1182800
HOUSING AS-REGULATOR
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 65E, 75D, 75E, 85D, 85E, 95E, C-10, C-12, MTC835, R1600, R1600G, R1700G, SBF214, SUF557, W345B II
140H, 143H, 14H, 160H, 163H, 16H, 3176C, 3196, 345B, 345B II, 345B II MH, 345B L, 65E, 75D, 75E, 85D, 85E, 95E, C-10, C-12, MTC835, R1600, R1600G, R1700G, SBF214, SUF557, W345B II
3E7858
HOUSING AS
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 135H, 135H NA, 140G, 140K, 140K 2, 160K, 214B, 3116, 3126, 3126B, 3126E, 320B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 32...
120H, 120H ES, 120H NA, 120K, 120K 2, 12K, 135H, 135H NA, 140G, 140K, 140K 2, 160K, 214B, 3116, 3126, 3126B, 3126E, 320B, 322B L, 322B LN, 322C, 322C FM, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 32...
1182801
HOUSING-REGULATOR
345B L, C-10
345B L, C-10
1252940
HOUSING
311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320B, 320B FM LL, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
311B, 311C, 312B, 312C, 312C L, 314C, 318C, 319C, 320B, 320B FM LL, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
1352359
HOUSING
311, 318C, 319C, 320B, 320B U, 320C, 320C FM, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320N, 321C, 321D LCR, 323D L, 323D LN, 323D SA
311, 318C, 319C, 320B, 320B U, 320C, 320C FM, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320N, 321C, 321D LCR, 323D L, 323D LN, 323D SA
1913235
HOUSING
315C, 315D L, 318C, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E ...
315C, 315D L, 318C, 318E L, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E ...
1913236
HOUSING
315C, 315D L, 318C, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321B, 321C, 321D LCR, 322B LN, 323D L, 323D LN, 323D2 L
315C, 315D L, 318C, 319C, 319D, 319D L, 319D LN, 320B, 320C, 320C FM, 320C L, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321B, 321C, 321D LCR, 322B LN, 323D L, 323D LN, 323D2 L
1484638
HOUSING
318C, 318E L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320...
318C, 318E L, 319C, 319D, 319D L, 319D LN, 320C, 320C FM, 320C L, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320...
3530612
HOUSING-MOTOR
318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 L, 323E ...
318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 GC, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 L, 323E ...
5I8041
HOUSING
320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
320B, 320C, 320C FM, 320C L, 320D, 320D LRR, 321C, 323D L, 323D LN
2676798
HOUSING
320D, 320D FM, 320D FM RR, 323D LN, 323D SA, 323E L, 325C, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
320D, 320D FM, 320D FM RR, 323D LN, 323D SA, 323E L, 325C, 325D, 325D L, 325D MH, 329D, 329D L, 329D LN, 329E, 329E L, 329E LN, OEMS
2276190
HOUSING-MOTOR
328D LCR, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN
328D LCR, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D, 336D L, 336D LN
1076480
HOUSING
307B
307B
1141525
HOUSING
312B
312B
0968796
HOUSING
307, E70, E70B
307, E70, E70B
1275832
HOUSING
312
312
1275833
HOUSING
312
312
1379256
HOUSING
307
307
1407436
HOUSING AS
966F II, D6R, D7R
966F II, D6R, D7R
1098176
HOUSING-TURBINE
140H, 143H, 14H, 160H, 163H, 973
140H, 143H, 14H, 160H, 163H, 973
6T8047
HOUSING
120K, 120K 2, 12K, 140K, 140K 2, 160K, 320B FM LL, 322B L, 322C, 322C FM, 325B L, 325C, 325C FM, 325D FM LL, 330B L, 330C FM, 330C L, 330C MH, 330D FM, 345B, 345B II, 345B II MH, 345B L, 568 FM LL, 76...
120K, 120K 2, 12K, 140K, 140K 2, 160K, 320B FM LL, 322B L, 322C, 322C FM, 325B L, 325C, 325C FM, 325D FM LL, 330B L, 330C FM, 330C L, 330C MH, 330D FM, 345B, 345B II, 345B II MH, 345B L, 568 FM LL, 76...
2063188
HOUSING
314C
314C
1859059
HOUSING
315B
315B
1362849
HOUSING
315B FM L
315B FM L