2005991 HOUSING GP-FRONT Caterpillar parts
301.5
Rating:
Alternative (cross code) number:
CA2005991
200-5991
2005991
CA2005991
200-5991
2005991
MINI HYD EXCAVATOR,
Compatible equipment models: 2005991:
Information:
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Low refrigerant charge will cause a loss of cooling ability and a loss of lubrication in the compressor, which will result in failure of the compressor.
Overcharge of refrigerant will cause a loss of cooling ability. A system that is overcharged will contain excess liquid refrigerant, which will severely damage the compressor. An overcharged system will fail two times faster than an undercharged system.
Too much oil in the system will contribute to a low refrigerant charge.
A small amount of moisture will penetrate the hoses that are used in R134a systems. Change the refrigerant dryer and the desiccant annually. Moisture causes sludge and moisture results in plugged systems.
Gauge readings for an undercharged R134a system may appear as symptoms of overcharge under certain conditions. This occurs when the ambient temperature is above 32 °C (90 °F) or in high humidity. Gauge readings that are Incorrect lead to a loss of cooling ability and failure of the compressor.
Refrigerant that is removed from a system cannot be weighed accurately. A 20 to 30% error can occur. The error is a result of oil that is removed from the system and a result of the inaccuracies of devices that are used for recovery.
Check the scale that is used for charging for accuracy after every 30 days or after every 30 uses.
After recovering a system, if the system pressure rises above 0 kPa (0 psi) within 5 minutes, the system must be recovered again until the pressure does not increase.
Frost can appear anywhere on a R134a air conditioning system. The appearance of frost does not always indicate a failure. In order to diagnose a blockage in the air conditioning system properly, the air temperature at the evaporator must be checked and pressure readings must be taken.
In order to check the function
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
1537974
HOUSING GP-FRONT
301.5
301.5
1092355
HOUSING-SWITCH
216, 228, 236, 236B, 242B, 247, 247B, 248, 267, 267B, 268B, 287, 301.5, 302.5, 303.5, 304.5, 550, 554, 564, 570, 574, 574B, 580, 933, 933C, 939, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G, M313C, ...
216, 228, 236, 236B, 242B, 247, 247B, 248, 267, 267B, 268B, 287, 301.5, 302.5, 303.5, 304.5, 550, 554, 564, 570, 574, 574B, 580, 933, 933C, 939, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G, M313C, ...
1537976
HOUSING-FRONT
301.5
301.5
2005992
HOUSING AS-FRONT
301.5
301.5
1568848
HOUSING AS
301.5
301.5
1471119
HOUSING-FLYWHEEL
301.5
301.5
2047326
HOUSING
301.5
301.5
1710363
HOUSING
301.5, 302.5
301.5, 302.5
1466389
HOUSING-FILTER
301.5, 302.5, 303.5, 304.5
301.5, 302.5, 303.5, 304.5
1537974
HOUSING GP-FRONT
301.5
301.5
1889048
HOUSING GP-FRONT
216, 228, 906
216, 228, 906
1701152
HOUSING & REGULATOR GP
D11N, D11R
D11N, D11R
2177118
HOUSING GP-FRONT
216, 216B, 232B, 242B, 3024C
216, 216B, 232B, 242B, 3024C
1862377
HOUSING GP-FRONT
3456, C-15, C-16, C-18, C18, CX35-P800
3456, C-15, C-16, C-18, C18, CX35-P800