2S1314 HOUSING A. Caterpillar parts
Rating:
Alternative (cross code) number:
CA2S1314
2S-1314
2S1314
CA2S1314
2S-1314
2S1314
Information:
CONTROL RECTIFIER SYMBOL
1. Anode. 2. Cathode. 3. Third terminal (gate).Control rectifiers (CR1 and CR2) are in effect, "on-off" valves that can either allow current to flow or can stop the flow of current through the excitation circuit. A control rectifier has the usual rectifier terminals, anode (1) and cathode (2), and a third terminal (3) that, for explanation purposes, will be referred to as the "gate". When gate (3) receives an electric impulse, it takes approximately 3 micro-seconds (.000003 second) for a control rectifier to "turn on" and allow current to flow. The control rectifier stays "on" until no current is flowing; then it turns "off". Because of no circuit from phase 3, current does not flow once during each complete cycle. Therefore, control rectifiers (CR1 and CR2) are "off" once each cycle and each gate must receive a signal to "turn on" the controlled rectifiers some time during the next cycle.The timing of the signal to the gate of each control rectifier (CR1 and CR2) is a function of regulator assembly (A1). As generator load increases, regulator assembly (A1) signals the "gates" of the control rectifiers earlier in the cycle, permitting a longer excitation time to the revolving field thereby providing the required additional excitation to maintain rated voltage with increased load. When generator load decreases, regulator assembly (A1) signals the "gates" later in the cycle and excitation time is less. Even when control rectifiers (CR1 and CR2) are "off" and current from phase 1 and phase 2 is blocked, revolving field excitation current is sustained for a complete cycle by the circuit that includes field rectifier (CR5). (Remember the flywheel analogy.)Build-up relay (K1) has the only moving part (except for the rotating field) in the entire exciting and regulating system. The relay has contact points that operate only when the generator is being started or stopped. The normally closed contact points in the build-up relay (K1) are connected, in effect, from phase 2 to the "gate"
Parts housing Caterpillar catalog:
2S0620
HOUSING
Caterpillar
Caterpillar
2S0148
HOUSING
Caterpillar
Caterpillar
2S0098
HOUSING
Caterpillar
Caterpillar
2S0091
HOUSING
Caterpillar
Caterpillar
2S0089
HOUSING A.
Caterpillar
Caterpillar
2R4469
HOUSING
Caterpillar
Caterpillar
2S2035
HOUSING
Caterpillar
Caterpillar
2S1773
HOUSING
Caterpillar
Caterpillar
2S1383
HOUSING
Caterpillar
Caterpillar
2S1359
HOUSING
Caterpillar
Caterpillar
2S1343
HOUSING
Caterpillar
Caterpillar
2S1315
HOUSING
Caterpillar
Caterpillar