Information:
(Action Alarm - Voltage Above Normal)
Illustration 1 g02276434
Schematic of the action alarm.
This diagnostic code is associated with the action alarm. The FMI 03 means that the Messenger module has determined that the voltage of the alarm circuit is above normal.The possible causes of the diagnostic code are listed below:
The action alarm has failed.
The energize circuit of the alarm is shorted to the +Battery circuit.
The dash cluster has failed. This cause is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the CID 271 FMI 3 diagnostic code is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE ALARM
Disconnect the harness connector from the action alarm.
Use jumpers to connect the respective terminals of the alarm to +Battery and ground. Expected Result:The action alarm sounds when power is applied.Results:
OK - The alarm sounds when power is applied. The alarm functions properly. Proceed to Test Step 2.
NOT OK - The alarm does NOT sound. The alarm has failed.Repair: Repeat this Test Step "Check the Alarm" to verify the failure of the alarm. Replace the alarm. Verify that the new alarm corrects the problem.STOPTest Step 2. CHECK THE ENERGIZE CIRCUIT OF THE ALARM FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
The machine harness connector remains disconnected from the alarm. Disconnect the machine harness from the dash cluster.
At the machine harness connector for the display module, measure the resistance from contact IC-23 (wire H414-YL(Yellow)) to all contacts that are used in the machine harness connectors for the dash cluster. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness for the dash cluster. The short is between IC-23 (H414-YL(Yellow)) and the circuit that has a low resistance measurement.Repair: Repair or replace the machine harness.STOPTest Step 3. CHECK THE HARNESS CONNECTORS
Inspect and clean the harness connector contacts.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 271 FMI 3 is active. Expected Result:The CID 0271 FMI 03 is active.Results:
YES - The CID 271 FMI 3 is active. The problem has not been corrected. The dash cluster may have failed.Repair: Failure of the dash cluster is unlikely. Perform this procedure again. If the cause of the diagnostic code is not found, replace the dash cluster. STOP
NO - The CID 271 FMI 3 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Illustration 1 g02276434
Schematic of the action alarm.
This diagnostic code is associated with the action alarm. The FMI 03 means that the Messenger module has determined that the voltage of the alarm circuit is above normal.The possible causes of the diagnostic code are listed below:
The action alarm has failed.
The energize circuit of the alarm is shorted to the +Battery circuit.
The dash cluster has failed. This cause is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the CID 271 FMI 3 diagnostic code is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE ALARM
Disconnect the harness connector from the action alarm.
Use jumpers to connect the respective terminals of the alarm to +Battery and ground. Expected Result:The action alarm sounds when power is applied.Results:
OK - The alarm sounds when power is applied. The alarm functions properly. Proceed to Test Step 2.
NOT OK - The alarm does NOT sound. The alarm has failed.Repair: Repeat this Test Step "Check the Alarm" to verify the failure of the alarm. Replace the alarm. Verify that the new alarm corrects the problem.STOPTest Step 2. CHECK THE ENERGIZE CIRCUIT OF THE ALARM FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
The machine harness connector remains disconnected from the alarm. Disconnect the machine harness from the dash cluster.
At the machine harness connector for the display module, measure the resistance from contact IC-23 (wire H414-YL(Yellow)) to all contacts that are used in the machine harness connectors for the dash cluster. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness for the dash cluster. The short is between IC-23 (H414-YL(Yellow)) and the circuit that has a low resistance measurement.Repair: Repair or replace the machine harness.STOPTest Step 3. CHECK THE HARNESS CONNECTORS
Inspect and clean the harness connector contacts.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 271 FMI 3 is active. Expected Result:The CID 0271 FMI 03 is active.Results:
YES - The CID 271 FMI 3 is active. The problem has not been corrected. The dash cluster may have failed.Repair: Failure of the dash cluster is unlikely. Perform this procedure again. If the cause of the diagnostic code is not found, replace the dash cluster. STOP
NO - The CID 271 FMI 3 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
2849085
HOUSING GP-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
2849086
HOUSING GP-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
2872080
HOUSING GP-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
2877221
HOUSING & REGULATOR GP
C13, TH35-C13T
C13, TH35-C13T
2877224
HOUSING & REGULATOR GP
C13, TH35-C13T
C13, TH35-C13T
7T3279
HOUSING AS
120G, 120M, 12G, 12H, 12H ES, 12H NA, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 160M, 163H, 163H NA, 1673C, 16G, 16H, 16H NA, 16M, 215B,...
120G, 120M, 12G, 12H, 12H ES, 12H NA, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 160M, 163H, 163H NA, 1673C, 16G, 16H, 16H NA, 16M, 215B,...
7T3974
HOUSING AS-DRIVE
1090, 1190, 1190T, 120G, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 1390, 140G, 140H, 140H ES, 140H NA, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA...
1090, 1190, 1190T, 120G, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 1390, 140G, 140H, 140H ES, 140H NA, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14G, 14H, 14H NA...
7T3973
HOUSING AS-LEVER
120G, 12G, 140G, 140H, 143H, 160H, 163H, 1673C, 16G, 215B, 245, 3176, 3176B, 3176C, 3196, 3208, 322C, 325, 325 L, 325C, 330 L, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, ...
120G, 12G, 140G, 140H, 143H, 160H, 163H, 1673C, 16G, 215B, 245, 3176, 3176B, 3176C, 3196, 3208, 322C, 325, 325 L, 325C, 330 L, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, ...
2849084
HOUSING-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
2872079
HOUSING-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
3010289
HOUSING-FLYWHEEL
C13, TH35-C13T
C13, TH35-C13T
3293062
HOUSING AS-FRONT
C13, TH35-C13T
C13, TH35-C13T
3589606
HOUSING GP-AXLE
950H, 950K, 962H, 962K
950H, 950K, 962H, 962K
3589605
HOUSING GP-AXLE
950H, 950K, 962H, 962K
950H, 950K, 962H, 962K
3589603
HOUSING GP-AXLE
950H, 950K, 962H, 962K
950H, 950K, 962H, 962K
3589602
HOUSING GP-AXLE
950H, 950K, 962H, 962K
950H, 950K, 962H, 962K
3437194
HOUSING & REGULATOR GP
C13, CX31-C13I
C13, CX31-C13I
3650074
HOUSING GP-FRONT
C13, CX31-C13I
C13, CX31-C13I