Information:
Illustration 1 g00713118
Solenoid testA basic four terminal starting motor solenoid circuit is shown in Illustration 1. The two windings that are found in the solenoid are the hold-in winding and the pull-in winding. The windings can be checked by using the procedures that follow.Hold-in Winding Test
Illustration 2 g00713128
Hold-in winding test
Refer to Illustration 2 in order to make the connections to the solenoid. Disconnect all other leads to the solenoid.
Close the switch.Observe the reading on the multimeter. Use the battery load tester to adjust the battery voltage until the following voltages are obtained: 12 Volt System ... 10 Volts 24 Volt System ... 20 Volts
Observe the reading on the clamp-on ammeter.The following amperes should be observed: 12 Volt System ... 9.9 to 10.0 Amperes 24 Volt System ... 18.8 to 20.0 AmperesNote: A high reading indicates a shorted winding. A low reading indicates excessive resistance.
The hold-in winding can also be checked by measuring the resistance.Disconnect the batteries. Select the "200 ê" range on the multimeter. Connect one of the leads of the multimeter to the "S" terminal and connect the other lead to the "G" terminal.The following Ohms should be observed: 12 Volt System ... 1.05 0.05 Ohms 24 Volt System ... 1.05 0.05 Ohms
Replace the solenoid if any of the above readings are incorrect.Pull-in Winding Test
Illustration 3 g00713129
Pull-in winding test
Refer to Illustration 3 in order to make the connections to the solenoid. Disconnect all other leads to the solenoid.
Close the switch.Observe the reading on the multimeter. Use the battery load tester to adjust the battery voltage until the following voltages are obtained: 12 Volt System ... 2.5 Volts 24 Volt System ... 5 Volts
Observe the reading on the clamp-on ammeter.The following amperes should be observed: 12 Volt System ... 10.0 to 10.87 Amperes 24 Volt System ... 20.0 to 21.74 AmperesNote: A high reading indicates a shorted winding. A low reading indicates excessive resistance. To avoid excessive heat, do not leave the switch closed for more than 10 seconds at a time. The current will decrease as the heat increases.
The pull-in winding can also be checked by measuring the resistance. Perform the measurement with a voltmeter that reads 0.01 Ohm.Disconnect the batteries. Select the "200 ê" range on the multimeter. Connect one of the leads of the multimeter to the "S" terminal and connect the other lead to the "Mtr" terminal.The following Ohms should be observed: 12 Volt System ... 0.24 0.01 Ohms 24 Volt System ... 0.24 0.01 Ohms
Replace the solenoid if any of the above readings are incorrect.
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
4549119
HOUSING & REGULATOR GP
Caterpillar
Caterpillar
4549023
HOUSING AS-REGULATOR
Caterpillar
Caterpillar
4536028
HOUSING AS
Caterpillar
Caterpillar
4504029
HOUSING AS-TURBINE
Caterpillar
Caterpillar
4493841
HOUSING AS-REGULATOR
Caterpillar
Caterpillar
4487868
HOUSING-TORQUE CONVERTER
Caterpillar
Caterpillar
4634986
HOUSING
Caterpillar
Caterpillar
4613787
HOUSING AS-TURBINE
Caterpillar
Caterpillar
4613727
HOUSING AS-TURBINE
Caterpillar
Caterpillar
4608976
HOUSING GP-FRONT
Caterpillar
Caterpillar
4577915
HOUSING AS-FRONT
Caterpillar
Caterpillar
4577914
HOUSING GP-FRONT
Caterpillar
Caterpillar