4669237 HOUSING-BEARING Caterpillar parts
Rating:
Alternative (cross code) number:
CA4669237
466-9237
4669237
CA4669237
466-9237
4669237
Weight: 12 pounds 5 kg.
Information:
Table 1
TOOLS NEEDED    
Part Number     Tool     Quantity    
6V-7070     Multimeter     1    Six-Diode Rectifier Block
Illustration 1 g00613957
Six-Diode Rectifier Block (one piece) (1) Positive Rectifier Block (2) Negative Rectifier Block (3) Rectifier Terminal "AC1" (4) Rectifier Terminal "AC2" (5) Rectifier Terminal "AC3"The following procedure tests all six diodes within the block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0 ohms.
Place the red test lead on the negative "-" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0 ohms.
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the negative "-" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).Note: A shorted diode can cause damage to the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor CR7. CR7 can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000 ohms. Two-Diode Rectifier Block
Illustration 2 g00610186
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
Place the black test lead on the AC rectifier terminal.
Place the red test lead on the negative "-" rectifier terminal. The reading on the meter should be between 0.4 and 1.0 ohms.
Place the red test lead on the positive "+" rectifier terminal. The reading on the meter should be "OL" (overload).
Place the red test lead on the AC rectifier terminal.
Place the black test lead on the negative "-" rectifier terminal. The reading on the meter should be "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. The reading on the meter should be between 0.4 and 1.0 ohms.Note: A shorted diode can cause damage to the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.
Cat SIS web machinery list:
Parts housing Caterpillar catalog:
4656711
HOUSING GP-FRONT
Caterpillar
Caterpillar
4638721
HOUSING AS
Caterpillar
Caterpillar
4623367
HOUSING AS-REAR
Caterpillar
Caterpillar
4613713
HOUSING AS-TURBINE
Caterpillar
Caterpillar
4586028
HOUSING GP-PUMP
Caterpillar
Caterpillar
4586027
HOUSING GP-PUMP
Caterpillar
Caterpillar
4775750
HOUSING GP-FRONT
Caterpillar
Caterpillar
4761944
HOUSING GP-SHEAR
Caterpillar
Caterpillar
4735462
HOUSING-CONTROL
Caterpillar
Caterpillar
4735461
HOUSING-CONTROL
Caterpillar
Caterpillar
4717065
HOUSING GP-ECCENTRIC WEIGHT
Caterpillar
Caterpillar
4717064
HOUSING GP-ECCENTRIC WEIGHT
Caterpillar
Caterpillar