4785982 HOUSING GP-FLY Caterpillar parts
Rating:
Alternative (cross code) number:
CA4785982
478-5982
4785982
CA4785982
478-5982
4785982
Information:
Illustration 1 g00749298
The Caterpillar Electronic Technician Software is equipped with a feature for calibrating the machine control system. The calibration mode is accessed by connecting the ET to the vehicle. Select the Machine Control ECM. This is shown in illustration 1.
Illustration 2 g00749477
Once the Machine Control ECM is selected, the calibration procedures are accessed through the "Service Menu". Select "Calibrations" from the menu. This is shown in illustration 2.
Illustration 3 g00749496
The warning for safety during calibration will be displayed on the ET screen. Select "OK" after reading the warning.The calibration of the electro-hydraulic control valve determines the point when hydraulic oil flow starts for all implement functions. Calibration determines the amount of electric current that must be sent to each valve in order to initiate flow to the cylinders. The amount of electric current that is required to establish full flow to the cylinders is determined. The Machine Control ECM records these currents in memory. The ECM uses these ranges until the ECM is replaced or the calibration procedure is performed again.For the initial calibration of the valve, you must perform all of the portions of the procedure: bowl, apron and ejector. During subsequent recalibrations, each section of the procedure may be performed independently.
Illustration 4 g00749483
(1) "Bowl Solenoids Calibration" (2) "Ejector Solenoids Calibration" (3) (Apron Solenoids Calibration)
Select the proper calibration. Select the required boxes. See illustration 4. In order to calibrate the solenoids for the ejector, select "Ejector Solenoids Calibration" (2).
Illustration 5 g00749487
The ET screen will instruct the technician to perform actions at location (4) and location (5). The actual instructions are listed below:
The vehicle parking brakes must be set.
Illustration 6 g00749017
198-1758 Electro-Hydraulic Calibration Service Tool Group
Illustration 7 g00749011
Test port for the pump pressure of the implement ( 621G and 627G)
Illustration 8 g00749014
198-1758 Electro-Hydraulic Calibration Service Tool Group Connected on the 621G and 627G
Illustration 9 g00768228
198-1758 Electro-Hydraulic Calibration Service Tool Group Connected on 623G
Attach the 198-1758 Electro-Hydraulic Calibration Service Tool Group to the test port for the implement pump pressure. Plug the end of the tool into the electrical harness for the transmission.
Start the engine and set the engine to high idle.
Operate the machine until the hydraulic oil temperature is between 50 °C (122 °F) and 75 °C (167 °F).
The bowl must be empty of material.
Move the ejector to the fully forward position. Ensure that the floor of the bowl is in the full back position.
After the previous initial conditions have been met, select the "NEXT" button in the ET.
Move the joystick into the full Forward Ejector position. Hold the joystick until the ET software indicates that the calibration
Caterpillar SIS machinery equipment:
Parts housing Caterpillar catalog:
4785639
HOUSING-MOTOR
Caterpillar
Caterpillar
4780511
HOUSING
Caterpillar
Caterpillar
4780124
HOUSING AS
Caterpillar
Caterpillar
4777005
HOUSING
Caterpillar
Caterpillar
4776985
HOUSING-PORT
Caterpillar
Caterpillar
4776927
HOUSING
Caterpillar
Caterpillar
4798351
HOUSING
Caterpillar
Caterpillar
4796643
HOUSING
Caterpillar
Caterpillar
4795988
HOUSING-AXLE
Caterpillar
Caterpillar
4793021
HOUSING AS-
Caterpillar
Caterpillar
4792056
HOUSING AS-LH
Caterpillar
Caterpillar
4792055
HOUSING AS-RH
Caterpillar
Caterpillar