Use this procedure to troubleshoot the Data link system. Also use this procedure if a diagnostic code in Table 1 is active or easily repeated.
Table 1
J1939 Code and Description CDL Code and Description Comments
639-9
J1939 Network #1 : Abnormal Update Rate 247-9
J1939 Network #1 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
639-14
J1939 Network #1 : Special Instruction 247-14
J1939 Network #1 : Special Instruction The affected ECM is missing expected parameters.
1231-9
J1939 Network #2 : Abnormal Update Rate 2348-9
J1939 Network #2 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1231-14
J1939 Network #2 : Special Instruction 2348-14
J1939 Network #2 : Special Instruction The affected ECM is missing expected parameters.
1235-9
J1939 Network #3 : Abnormal Update Rate 5856-9
J1939 Network #3 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1235-14
J1939 Network #3 : Special Instruction 5856-14
J1939 Network #3 : Special Instruction The affected ECM is missing expected parameters.
2853-9
Communications Connection : Abnormal Update Rate N/A Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
3360-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate 3820-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate The DCU triggered a CAN communication diagnostic code and shut the SCR system down. Troubleshoot and repair the same as a 1235-9 code, perform an Aftertreatment System Functional Test to verify the repair
Table 2
Associated Diagnostic Trouble Codes
J1939 Code CDL Code
5965-5 3838-5
5965-6 3838-6
5966-6 3965-6 If the Cat® Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the ECM and to the service tool connector.The Systems Communication Status is located under the diagnostics tab in Cat ET. Click the "System Communication Status" option. Once the screen opens up, the information will automatically be loaded from the ECM. If there is an issue with the data link and the data link is repaired, the "Load from ECM" button will have to be clicked again to see the updated status. If there are communication issues between multiple modules, each module can be selected individually to determine which components are having communication issues. If the problem is intermittent, the "View History" button can be clicked to see all the communication faults that have previously logged.
Table 3
Cat® ET Diagnostic Code Cross Reference to Wiring Schematic
Code Description Data Link
J1939 Network #1 Can A
J1939 Network #2 Can B
J1939
Table 1
J1939 Code and Description CDL Code and Description Comments
639-9
J1939 Network #1 : Abnormal Update Rate 247-9
J1939 Network #1 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
639-14
J1939 Network #1 : Special Instruction 247-14
J1939 Network #1 : Special Instruction The affected ECM is missing expected parameters.
1231-9
J1939 Network #2 : Abnormal Update Rate 2348-9
J1939 Network #2 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1231-14
J1939 Network #2 : Special Instruction 2348-14
J1939 Network #2 : Special Instruction The affected ECM is missing expected parameters.
1235-9
J1939 Network #3 : Abnormal Update Rate 5856-9
J1939 Network #3 : Abnormal Update Rate Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
1235-14
J1939 Network #3 : Special Instruction 5856-14
J1939 Network #3 : Special Instruction The affected ECM is missing expected parameters.
2853-9
Communications Connection : Abnormal Update Rate N/A Communication has been lost to one or more of the devices on the datalink. If multiple devices are not communicating, there is likely a problem with the data link wiring, power, or ground circuits.
3360-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate 3820-9
Aftertreatment #1 DEF Controller : Abnormal Update Rate The DCU triggered a CAN communication diagnostic code and shut the SCR system down. Troubleshoot and repair the same as a 1235-9 code, perform an Aftertreatment System Functional Test to verify the repair
Table 2
Associated Diagnostic Trouble Codes
J1939 Code CDL Code
5965-5 3838-5
5965-6 3838-6
5966-6 3965-6 If the Cat® Electronic Technician (ET) will not communicate with the ECM, refer to Troubleshooting, "Electronic Service Tool Does Not Communicate" before you begin this procedure. The procedure verifies that electrical power is being supplied to the ECM and to the service tool connector.The Systems Communication Status is located under the diagnostics tab in Cat ET. Click the "System Communication Status" option. Once the screen opens up, the information will automatically be loaded from the ECM. If there is an issue with the data link and the data link is repaired, the "Load from ECM" button will have to be clicked again to see the updated status. If there are communication issues between multiple modules, each module can be selected individually to determine which components are having communication issues. If the problem is intermittent, the "View History" button can be clicked to see all the communication faults that have previously logged.
Table 3
Cat® ET Diagnostic Code Cross Reference to Wiring Schematic
Code Description Data Link
J1939 Network #1 Can A
J1939 Network #2 Can B
J1939
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
7N9738
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
9T4684
HOUSING
120G, 12G, 130G, 140G, 14G, 160G, 16G, 446B, 446D, 916, D5C III, D6H, D6H XL, D6H XR, D7H, D8N, D8R, D9R, IT18B
120G, 12G, 130G, 140G, 14G, 160G, 16G, 446B, 446D, 916, D5C III, D6H, D6H XL, D6H XR, D7H, D8N, D8R, D9R, IT18B
3P0887
HOUSING AS
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H, 16H NA, 589, 611, 61...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H, 16H NA, 589, 611, 61...
8D9973
HOUSING
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H, 16H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H, 16H NA
3P0318
HOUSING AS-SUPPORT
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
8W4652
HOUSING-SPINDLE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
8W4653
HOUSING-SPINDLE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
8D9804
HOUSING-DRIVE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
9D8972
HOUSING AS-DIFFERENTIAL
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
5T7125
HOUSING
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
5T7129
HOUSING
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
8W8124
HOUSING
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G
9D8772
HOUSING
12G, 130G
12G, 130G
8D3777
HOUSING
12G, 130G
12G, 130G
3G1763
HOUSING
120G
120G
3G2327
HOUSING
120G, 140G, 14G, 16G
120G, 140G, 14G, 16G
6G3803
HOUSING
16G
16G
6G3286
HOUSING
16G
16G
6G1959
HOUSING
120G
120G
6G1971
HOUSING
16G
16G
6G1967
HOUSING
130G
130G