6N1347 HOUSING AS-PUMP Caterpillar parts
12G, 14G, 1673C, 235, 3306, 627B, 637D, D5, D6C, D6D, D7F
Rating:
Alternative (cross code) number:
CA6N1347
6N-1347
6N1347
CA6N1347
6N-1347
6N1347
Weight: 0.01 pounds 0 kg.
EXCAVATOR, WHEEL SCRAPER,
Compatible equipment models: 6N1347:
Information:
Sudden movement of the machine or release of oil under pressure can cause serious injury to persons on or near the machine.To prevent possible injury, perform the procedure that follows before testing and adjusting the hydraulic system.
Cold ambient temperatures could result in the loss of secondary braking capability due to inadequate hydraulic accumulator nitrogen pre-charge. The loss of the secondary braking system as well as the main hydraulic pressure will result in little or no braking capability and a potential for injury or death.It is recommended to perform a brake accumulator check anytime the machine has been idle for longer than two hours below −25 °C (−13 °F). Refer to Operation and Maintenance Manual before performing any check of the brake accumulator.
Specifications
Table 1
Accumulator Precharge Pressure/Temperature Relationship for a Typical 5000 kPa (725 psi) Brake Accumulator
Temperature Pressure(1)
-1°C (30°F) 4630 kPa (672 psi)
4°C (40°F) 4717 kPa (685 psi)
10°C (50°F) 4808 kPa (698 psi)
16°C (60°F) 4902 kPa (711 psi)
21°C (70°F) 5000 kPa (725 psi)
27°C (80°F) 5102 kPa (740 psi)
32°C (90°F) 5208 kPa (756 psi)
38°C (100°F) 5263 kPa (764 psi)
43°C (110°F) 5376 kPa (780 psi)
49°C (120°F) 5495 kPa (798 psi)
(1) The tolerance on the nominal pressure is 248 kPa ( 36 psi).Introduction
The brake accumulators are mounted ahead of the right front wheel well. The purpose of the accumulator is to store pressure. This stored pressure will allow the machine operator to bring the machine to a stop in the event of an interruption of pressure from the brake pump.The following procedure will determine if the accumulator is charged to the appropriate pressure.Accumulator Charge Pressure
Refer to Special Instruction, REHS5464, "Accumulator Discharging and Charging Procedures".Lowering the Piston in Brake Accumulators
Hydraulic accumulator contains gas and oil under high pressure. Improper removal or repair procedures could cause severe injury. To remove or repair, instructions in the service manual must be followed. Special equipment is required for testing and charging.
Note: Relieving the pressure in the brake circuit will not release the nitrogen precharge pressure in the brake accumulators.
Remove the pressure from the brake system by pumping the service brake pedal at a rate of one second ON and one second OFF. Continue to pump the brakes until the pressure at the TF port on the fan/brake manifold is less than 140 kPa (20 psi). Do not assume that the pressure is removed from the circuit if the brake pedal has no resistance.To charge the accumulator, the piston in the brake accumulator must be on the bottom of the cylinder. The air temperature outside the accumulator is the ambient temperature. Before the dry nitrogen pressure in the accumulator can be accurately checked, the temperature of the accumulator must be equal to the ambient temperature. Before the accumulator may be correctly charged, the temperature of the accumulator must be equal to the ambient temperature.Use Table 1 to determine the correct charging pressure for the 367-4898 Hydraulic Accumulator Gp, or the 367-4897 Hydraulic Accumulator Gp.Note: The 367-4897 Hydraulic
Cat SIS web machinery list:
Parts housing Caterpillar catalog:
3P0318
HOUSING AS-SUPPORT
120G, 12G, 130G, 140G, 160G
120G, 12G, 130G, 140G, 160G
8W4652
HOUSING-SPINDLE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
8W4653
HOUSING-SPINDLE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 160G, 160H, 160H ES, 160H NA, 160K
6G1908
HOUSING AS-DRIVE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
8D9804
HOUSING-DRIVE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H, 163H NA
9D8972
HOUSING AS-DIFFERENTIAL
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
5T7125
HOUSING
12G, 130G, 140G, 160G
12G, 130G, 140G, 160G
5T7129
HOUSING
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA
8W8124
HOUSING
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G
12G, 12H, 12H ES, 12H NA, 12K, 130G, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160G
1104652
HOUSING
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 160H, 160H ES, 160H NA, 163H NA
3P7042
HOUSING-CLUTCH
14G, 14H, 14H NA, 16G, 16H, 16H NA
14G, 14H, 14H NA, 16G, 16H, 16H NA
8W8167
HOUSING
14G, 14H, 14H NA
14G, 14H, 14H NA
6N8412
HOUSING
3304, 3306, G3304, G3306
3304, 3306, G3304, G3306
7N7252
HOUSING ASSEM.
1673C, 3304, 3306, 627B, D8H
1673C, 3304, 3306, 627B, D8H
6N7276
HOUSING ASSEM.
245, 3406, 621B
245, 3406, 621B
7M8673
HOUSING
D343
D343
4M4414
HOUSING
D343
D343
5N1763
HOUSING ASSEM.
D398, D399
D398, D399
6L2243
HOUSING ASSEM.
D342, D342C
D342, D342C
6H6661
HOUSING
D353C
D353C
3F6519
HOUSING
D315
D315
3F6386
HOUSING
D315
D315
3S2206
HOUSING
3304
3304