7Y0898 HOUSING - SPROCKET Caterpillar parts
325, 325 L, 325 LN
Rating:
Alternative (cross code) number:
CA7Y0898
7Y-0898
7Y0898
CA7Y0898
7Y-0898
7Y0898
Weight: 149 pounds 67 kg.
EXCAVATOR,
This part in 2 request:
Show.
This information for suppliers only!
2021-12-20
2021-12-20
Information:
Using the 6V-6106 Dial Indicator Gp With A Reduced Calibration Dimension
Table 1
Required Tools    
Part Number     Part Description     Qty    
6V-6106     Dial Indicator Gp     1    
1U-8815     Indicator Contact Point     1    
Adjust the position of the dial indicator on the indicator bracket so that the dial indicator reads 6.00 mm (0.236 inch). Refer to the appropriate Steps in the Testing and Adjusting, "Installation of Governor on 1U-7326 Governor Calibration Bench " section in this manual for more information. Tighten the locking screw on the dial indicator in order to lock the dial indicator in position.The 6.00 mm (0.236 inch) dimension now becomes the reference point for all other adjustments made on the calibration bench. All of the other governor output dimensions must be reduced by 2.00 mm (0.079 inch) since the 6.00 mm (0.236 inch) reference point is 2.00 mm (0.079 inch) less than the 8.00 mm (0.315 inch) reference point using this modified method.Using the Programmable 1U-8869 Dial Indicator
Table 2
Required Tools    
Part Number     Part Description     Qty    
1U-8869     Dial Indicator     1    
6V-2030     Extension     1    
1U-8815     Indicator Contact Point     1    
1U-7316     Calibration Pin Group     1    
Turn on the dial indicator and set the dial indicator to reverse mode. Set the dial indicator to reverse mode by pressing the "+/-" button so that the dash (-) appears in the display under the "REV" heading. This setting will allow the dial indicator to display lower values as the stem is pushed in.
Preset the dial indicator to 8.00 mm (0.315 inch). The procedure for presetting the dial indicator is described in the operation manual for the dial indicator.
Install the extension and the contact point on the dial indicator.
Install the 1U-7316 Calibration Pin Group in the governor output clevis. Hook up the throttle spring so that the calibration pin is held tightly against the governor calibration face. The spring will hold the throttle in the high idle position.
Connect the test bench to an electrical outlet.
Turn the switch for the pump to the ON position.
Press the red "zero" button on the dial indicator and insert the dial indicator into the bracket on the calibration bench.
After the tip of the dial indicator contacts the governor output clevis pin, continue to slide the dial indicator into the indicator bracket. When the dial indicator reads -3.00 to -2.75 mm (-0.118 to -0.108 inch), lock the dial indicator in position with the setscrew. This step will ensure proper travel of the dial indicator.
Push the "preset" button on the dial indicator twice. The dial indicator should read 8.00 mm (0.315 inch).
Actuate the throttle in order to ensure that the 8.00 mm (0.315 inch) reference point has not changed.
Remove the calibration pin from the governor output clevis and proceed with the desired checking or the desired adjusting procedures.
Table 1
Required Tools    
Part Number     Part Description     Qty    
6V-6106     Dial Indicator Gp     1    
1U-8815     Indicator Contact Point     1    
Adjust the position of the dial indicator on the indicator bracket so that the dial indicator reads 6.00 mm (0.236 inch). Refer to the appropriate Steps in the Testing and Adjusting, "Installation of Governor on 1U-7326 Governor Calibration Bench " section in this manual for more information. Tighten the locking screw on the dial indicator in order to lock the dial indicator in position.The 6.00 mm (0.236 inch) dimension now becomes the reference point for all other adjustments made on the calibration bench. All of the other governor output dimensions must be reduced by 2.00 mm (0.079 inch) since the 6.00 mm (0.236 inch) reference point is 2.00 mm (0.079 inch) less than the 8.00 mm (0.315 inch) reference point using this modified method.Using the Programmable 1U-8869 Dial Indicator
Table 2
Required Tools    
Part Number     Part Description     Qty    
1U-8869     Dial Indicator     1    
6V-2030     Extension     1    
1U-8815     Indicator Contact Point     1    
1U-7316     Calibration Pin Group     1    
Turn on the dial indicator and set the dial indicator to reverse mode. Set the dial indicator to reverse mode by pressing the "+/-" button so that the dash (-) appears in the display under the "REV" heading. This setting will allow the dial indicator to display lower values as the stem is pushed in.
Preset the dial indicator to 8.00 mm (0.315 inch). The procedure for presetting the dial indicator is described in the operation manual for the dial indicator.
Install the extension and the contact point on the dial indicator.
Install the 1U-7316 Calibration Pin Group in the governor output clevis. Hook up the throttle spring so that the calibration pin is held tightly against the governor calibration face. The spring will hold the throttle in the high idle position.
Connect the test bench to an electrical outlet.
Turn the switch for the pump to the ON position.
Press the red "zero" button on the dial indicator and insert the dial indicator into the bracket on the calibration bench.
After the tip of the dial indicator contacts the governor output clevis pin, continue to slide the dial indicator into the indicator bracket. When the dial indicator reads -3.00 to -2.75 mm (-0.118 to -0.108 inch), lock the dial indicator in position with the setscrew. This step will ensure proper travel of the dial indicator.
Push the "preset" button on the dial indicator twice. The dial indicator should read 8.00 mm (0.315 inch).
Actuate the throttle in order to ensure that the 8.00 mm (0.315 inch) reference point has not changed.
Remove the calibration pin from the governor output clevis and proceed with the desired checking or the desired adjusting procedures.
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
7N9738
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
7N7781
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 214, 215, 215D, 225, 225D, 227, 2...
120G, 120H, 120H ES, 120H NA, 12G, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 214, 215, 215D, 225, 225D, 227, 2...
7N9737
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 215B, 225, 225D, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 215B, 225, 225D, ...
7T3279
HOUSING AS
120G, 120M, 12G, 12H, 12H ES, 12H NA, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 160M, 163H, 163H NA, 1673C, 16G, 16H, 16H NA, 16M, 215B,...
120G, 120M, 12G, 12H, 12H ES, 12H NA, 12M, 130G, 140G, 140H, 140H ES, 140H NA, 140M, 143H, 14G, 14H, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 160M, 163H, 163H NA, 1673C, 16G, 16H, 16H NA, 16M, 215B,...
7T3973
HOUSING AS-LEVER
120G, 12G, 140G, 140H, 143H, 160H, 163H, 1673C, 16G, 215B, 245, 3176, 3176B, 3176C, 3196, 3208, 322C, 325, 325 L, 325C, 330 L, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, ...
120G, 12G, 140G, 140H, 143H, 160H, 163H, 1673C, 16G, 215B, 245, 3176, 3176B, 3176C, 3196, 3208, 322C, 325, 325 L, 325C, 330 L, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, ...
7Y0607
HOUSING
322 FM L, 325, 325 L, 325 LN
322 FM L, 325, 325 L, 325 LN
0874755
HOUSING-CONTROL
320 L, 322, 322 FM L, 325, 325 LN
320 L, 322, 322 FM L, 325, 325 LN
1140772
HOUSING-CONTROL
320 L, 320N, 322, 322 FM L, 322 LN, 325
320 L, 320N, 322, 322 FM L, 322 LN, 325
1140672
HOUSING-CONTROL
320 L, 320N, 322, 322 FM L, 322 LN, 325
320 L, 320N, 322, 322 FM L, 322 LN, 325
1140671
HOUSING-PUMP
320 L, 325
320 L, 325
6I2262
HOUSING-COMPRESSOR
325, 325 L
325, 325 L
6I2261
HOUSING-TURBINE
325, 325 L
325, 325 L
7Y1791
HOUSING
320 L, OEMS
320 L, OEMS
7Y1767
HOUSING-COVER
320 L, 345B, 345B L, OEMS
320 L, 345B, 345B L, OEMS
0874775
HOUSING-CONTROL
325, 325 LN, 330, 330 FM L, 330 L
325, 325 LN, 330, 330 FM L, 330 L
7Y0394
HOUSING - MOTOR
325, 325 L, 325 LN
325, 325 L, 325 LN