7Y1753 HOUSING Caterpillar parts
320 L, 320N
Rating:
Alternative (cross code) number:
CA7Y1753
7Y-1753
7Y1753
CA7Y1753
7Y-1753
7Y1753
Weight: 134 pounds 60 kg.
EXCAVATOR,
Information:
Adjustment Procedure
Generator Configuration
Illustration 1 g01106859
Cat Electronic Technician (Configuration screen)The Implement Generator Installation Status parameter (1) must be "installed" by using the Configuration Screen with ET.The generator configuration must be identified after installing the generator. Always set the Implement Generator Hydraulic Flow Setting parameter (2) to "LOW". The "HIGH" setting is not used and will not increase magnet performance.Set the Operating Voltage
: High voltage exists at the generator system when the generator is activated.Note: Generator speed should always be set before adjusting the Operating Voltage.In order to provide a sufficient operating voltage measure the voltage only with a connected and activated magnet. The main disconnect switch and the main breaker at the magnet controller must be in the ON position.
Illustration 2 g01370147
15 kW Controller (3) Resistor R1 (4) R1 Variable Resistor Adjustment (5) Boost Timer K7 (6) Drop Timer K12 (7) Terminal Block (AA) Main Breaker F1
Illustration 3 g01109255
Terminal Block (8) Terminal 11 (9) Terminal 12Turn on the generator and activate the magnet. Check the Operating Voltage across terminals 11 (8) and 12 (9) of the terminal block (7). The Operating Voltage should be 230 5 VDC under load (Magnet ON). In order to adjust the Operating Voltage, first turn off the generator and the engine.Set the output voltage to 230 +/- 5 VDC by adjusting R1 (3) .
Move the R1 Variable adjustment (4) to the LEFT in order to increase the Operating Voltage of the generator. This will decrease the resistance of R1.
Move the R1 Variable adjustment (4) to the RIGHT in order to decrease the Operating Voltage of the generator. This will increase the resistance of R1.
This adjustment does not affect BOOST or DROP Voltage.Boost Voltage
The Boost Voltage should be 260 +/- 10 VDC. Boost Voltage can be measured during the Boost Time period across terminals 11 (8) and 12 (9) of the terminal block (7). If the Operating Voltage is set correctly, the Boost Voltage should also be correct. Adjustment of the Boost Voltage is not possible.Boost Time
Boost Timer K7 (5) controls the amount of time in which the boost voltage is applied when the magnet is activated. The Boost time should be set to 2 seconds.
Illustration 4 g01129443
Boost Timer K7 (10) Timer dial (11) Multiplier switch (12) Seconds/Minutes select switch
Adjust K7 Timer dial (10) DOWN only if magnet is hot (90 deg. Celsius) by the end of a 8 hour shift
Adjust K7 Timer dial (10) UP to a maximum of 3 seconds only if magnet responds poorly
"x 1" (11) should be selected (Blocked by epoxy)
"S" (12) should be selected (Blocked by epoxy)Note: Never adjust BOOST time above 3 seconds. Performance will not be enhanced. Overheating of the magnet can result.Adjust The Drop Time
Illustration 5 g01129512
15 kW Controller system only (13) Drop Time Controller (located in the cab) S2Drop Timer (6) K12 and the Drop Time Controller (13) S2 work in combination to control the magnet drop time. The Drop Timer (6) K12 should be set to 3 seconds. Do not adjust. The switches on the face of (6) K12 should
Generator Configuration
Illustration 1 g01106859
Cat Electronic Technician (Configuration screen)The Implement Generator Installation Status parameter (1) must be "installed" by using the Configuration Screen with ET.The generator configuration must be identified after installing the generator. Always set the Implement Generator Hydraulic Flow Setting parameter (2) to "LOW". The "HIGH" setting is not used and will not increase magnet performance.Set the Operating Voltage
: High voltage exists at the generator system when the generator is activated.Note: Generator speed should always be set before adjusting the Operating Voltage.In order to provide a sufficient operating voltage measure the voltage only with a connected and activated magnet. The main disconnect switch and the main breaker at the magnet controller must be in the ON position.
Illustration 2 g01370147
15 kW Controller (3) Resistor R1 (4) R1 Variable Resistor Adjustment (5) Boost Timer K7 (6) Drop Timer K12 (7) Terminal Block (AA) Main Breaker F1
Illustration 3 g01109255
Terminal Block (8) Terminal 11 (9) Terminal 12Turn on the generator and activate the magnet. Check the Operating Voltage across terminals 11 (8) and 12 (9) of the terminal block (7). The Operating Voltage should be 230 5 VDC under load (Magnet ON). In order to adjust the Operating Voltage, first turn off the generator and the engine.Set the output voltage to 230 +/- 5 VDC by adjusting R1 (3) .
Move the R1 Variable adjustment (4) to the LEFT in order to increase the Operating Voltage of the generator. This will decrease the resistance of R1.
Move the R1 Variable adjustment (4) to the RIGHT in order to decrease the Operating Voltage of the generator. This will increase the resistance of R1.
This adjustment does not affect BOOST or DROP Voltage.Boost Voltage
The Boost Voltage should be 260 +/- 10 VDC. Boost Voltage can be measured during the Boost Time period across terminals 11 (8) and 12 (9) of the terminal block (7). If the Operating Voltage is set correctly, the Boost Voltage should also be correct. Adjustment of the Boost Voltage is not possible.Boost Time
Boost Timer K7 (5) controls the amount of time in which the boost voltage is applied when the magnet is activated. The Boost time should be set to 2 seconds.
Illustration 4 g01129443
Boost Timer K7 (10) Timer dial (11) Multiplier switch (12) Seconds/Minutes select switch
Adjust K7 Timer dial (10) DOWN only if magnet is hot (90 deg. Celsius) by the end of a 8 hour shift
Adjust K7 Timer dial (10) UP to a maximum of 3 seconds only if magnet responds poorly
"x 1" (11) should be selected (Blocked by epoxy)
"S" (12) should be selected (Blocked by epoxy)Note: Never adjust BOOST time above 3 seconds. Performance will not be enhanced. Overheating of the magnet can result.Adjust The Drop Time
Illustration 5 g01129512
15 kW Controller system only (13) Drop Time Controller (located in the cab) S2Drop Timer (6) K12 and the Drop Time Controller (13) S2 work in combination to control the magnet drop time. The Drop Timer (6) K12 should be set to 3 seconds. Do not adjust. The switches on the face of (6) K12 should
Caterpillar parts catalog:
Parts housing Caterpillar catalog:
5I7757
HOUSING GP-FRONT
320, 320 L, 320B, 320B L, 320B U, 320N, 321B
320, 320 L, 320B, 320B L, 320B U, 320N, 321B
5I7971
HOUSING GP-FRONT
320, 320 L, 320B, 320B FM LL, 320B U, 320N
320, 320 L, 320B, 320B FM LL, 320B U, 320N
7N9738
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 211B, 215, 215B, ...
7N9737
HOUSING-RECEPTACLE
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 215B, 225, 225D, ...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 215B, 225, 225D, ...
1141486
HOUSING
318B, 320B, 320C, 320N, 322, 322B, 322B L, 322B LN, OEMS
318B, 320B, 320C, 320N, 322, 322B, 322B L, 322B LN, OEMS
1352359
HOUSING
311, 318C, 319C, 320B, 320B U, 320C, 320C FM, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320N, 321C, 321D LCR, 323D L, 323D LN, 323D SA
311, 318C, 319C, 320B, 320B U, 320C, 320C FM, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320N, 321C, 321D LCR, 323D L, 323D LN, 323D SA
5I5138
HOUSING
311, 311B, 312B, 320 L, 320B, E110B, E120B, E200B
311, 311B, 312B, 320 L, 320B, E110B, E120B, E200B
5I5149
HOUSING
311, 311B, 312B, 320 L, 320B, E110B, E120B, E200B
311, 311B, 312B, 320 L, 320B, E110B, E120B, E200B
1141485
HOUSING-MOTOR
320 L, 320B, 320N, 322, 322B L, 322B LN, OEMS
320 L, 320B, 320N, 322, 322B L, 322B LN, OEMS
5I7509
HOUSING
320 L, 320B
320 L, 320B
7Y1438
HOUSING-MOTOR
320 L, 322, 322 FM L, 322 LN, OEMS
320 L, 322, 322 FM L, 322 LN, OEMS
7Y1437
HOUSING-SPROCKET
320 L, 322, 322 FM L, 322 LN, OEMS
320 L, 322, 322 FM L, 322 LN, OEMS
2158506
HOUSING
321C
321C
1624398
HOUSING
321C, 325C, 325D, 330C, 330D L, 336D L
321C, 325C, 325D, 330C, 330D L, 336D L
0854733
HOUSING
320, 325, E110B, E120B, E200B, E240C, EL240B
320, 325, E110B, E120B, E200B, E240C, EL240B
8278047
HOUSING
FB221
FB221
5534034
HOUSING
FB221
FB221
4605064
HOUSING, BARREL
FB221
FB221
1604885
HOUSING GP-OUTPUT
D10R, D11R, D9R
D10R, D11R, D9R
1309233
HOUSING AS
D10R, D11R, D9R
D10R, D11R, D9R
4P8733
HOUSING
D8L, D9N, D9R
D8L, D9N, D9R
1273605
HOUSING AS
D10N, D10R, D8L, D9L, D9N, D9R
D10N, D10R, D8L, D9L, D9N, D9R
1160771
HOUSING
325B
325B
1352337
HOUSING
320N
320N