The proportional reducing valve for the power shift pressure is located on the main pump housing. The proportional reducing valve sends the reduced pilot oil pressure to the regulators at the front pump and the rear pump. The output flow of the rear pump and the front pump is controlled in accordance with the power shift pressure. Power shift pressure is controlled by the machine ECM.Preliminary Test
Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust"Required Tools
Illustration 1 g01623868
Tooling group "B"
198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Part Number Description Qty
B 198-4240 Digital Pressure Indicator Gp
B1 198-4234 Indicator 1
B2 198-4237 Pressure Sensor 3447 kPa (500 psi) 1
B3 198-4236 Extension Cable 1 Machine Preparation
Position the machine on level ground.
Stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g03567361
Pump compartment
(1) Pressure tap (delivery pressure for front pump 1)
(2) Pressure tap (delivery pressure for rear pump 2)
(3) Pressure tap (power shift pressure)
(4) Pressure tap (front pump 1 negative flow)
(5) Pressure tap (rear pump 2 negative flow)
Connect a 3447 kPa (500 psi) pressure sensor to the pressure tap for power shift pressure. Calibration Procedure
Monitor Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Enter the "Service" Menu.
Enter service password "9992".
Select the "Calibration" Menu.
Select "Power Shift Pressure".
Follow the instructions on the screen to complete the calibration procedure.
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Note: The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.ET Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Select the ECM for "Machine Control".
Select "Calibrations" from the "Service" menu.
Select "PRV - Power Shift Pressure" and click the "Start" button.
Follow the instructions on the screen to complete the calibration procedure. Click "Next" button to continue through to the next step.
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Click the finish button to exit or move on to the next calibration. Note: If the calibration failed, the calibration is not saved. Click the "Restart" button to try the calibration again or click the "Finish" button to exit or move on to the next calibration.
The proportional reducing valve for the power shift pressure is located on the main pump housing. The proportional reducing valve sends the reduced pilot oil pressure to the regulators at the front pump and the rear pump. The output flow of the rear pump and the front pump is controlled in accordance with the power shift pressure. Power shift pressure is controlled by the machine ECM.Preliminary Test
Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust"Required Tools
Illustration 1 g01623868
Tooling group "B"
198-4240 Digital Pressure Indicator Gp
Table 1
Tool Item Part Number Description Qty
B 198-4240 Digital Pressure Indicator Gp
B1 198-4234 Indicator 1
B2 198-4237 Pressure Sensor 3447 kPa (500 psi) 1
B3 198-4236 Extension Cable 1 Machine Preparation
Position the machine on level ground.
Stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".
Illustration 2 g03567361
Pump compartment
(1) Pressure tap (delivery pressure for front pump 1)
(2) Pressure tap (delivery pressure for rear pump 2)
(3) Pressure tap (power shift pressure)
(4) Pressure tap (front pump 1 negative flow)
(5) Pressure tap (rear pump 2 negative flow)
Connect a 3447 kPa (500 psi) pressure sensor to the pressure tap for power shift pressure. Calibration Procedure
Monitor Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Enter the "Service" Menu.
Enter service password "9992".
Select the "Calibration" Menu.
Select "Power Shift Pressure".
Follow the instructions on the screen to complete the calibration procedure.
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Note: The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.ET Procedure
Start the engine.
Increase the hydraulic oil temperature to 55° 5°C (131° 9°F).
Select the ECM for "Machine Control".
Select "Calibrations" from the "Service" menu.
Select "PRV - Power Shift Pressure" and click the "Start" button.
Follow the instructions on the screen to complete the calibration procedure. Click "Next" button to continue through to the next step.
If calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Click the finish button to exit or move on to the next calibration. Note: If the calibration failed, the calibration is not saved. Click the "Restart" button to try the calibration again or click the "Finish" button to exit or move on to the next calibration.
Parts housing Caterpillar catalog:
8H6165
HOUSING
Caterpillar
Caterpillar
8H5904
HOUSING A.
Caterpillar
Caterpillar
8H5123
HOUSING
Caterpillar
Caterpillar
8H4667
HOUSING A.
Caterpillar
Caterpillar
8H4333
HOUSING
Caterpillar
Caterpillar
8H3039
HOUSING
Caterpillar
Caterpillar
8H9228
HOUSING
Caterpillar
Caterpillar
8H8696
HOUSING
Caterpillar
Caterpillar
8H7564
HOUSING A.
Caterpillar
Caterpillar
8H7563
HOUSING
Caterpillar
Caterpillar
8H7461
HOUSING
Caterpillar
Caterpillar
8H6862
HOUSING
Caterpillar
Caterpillar