1387034 HUB-CLUTCH Caterpillar parts
725, 725C, 730, 735, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
Rating:
Alternative (cross code) number:
CA1387034
138-7034
1387034
CA1387034
138-7034
1387034
Weight: 5 pounds 2 kg.
ARTICULATED TRUCK, PETROLEUM TRANSMISSION,
Compatible equipment models: 1387034:
Information:
Use this procedure if you suspect that there is a problem with the circuit for the user defined shutdown switch.The user defined shutdown can be connected to any electronic switch or to any mechanical switch in the electrical system that would shut down the engine for any reason. When the signal is grounded, an event code is logged in memory and the Electronic Control Module (ECM) disables injection.The input must be pulled below 0.5 VDC before the ECM will recognize the shutdown signal. Prior to the enabling of the user defined shutdown by the ECM, certain events may be required to be satisfied by the operator. Examples of these events would include engagement of the parking brake or a machine ground speed of zero. Refer to the machine's Operation and Maintenance Manual for the specific events that apply.
Illustration 1 g01120571
Schematic
Test Step 1. Inspect Electrical Connectors and Wiring
Remove the electrical power from the ECM.
Thoroughly inspect the J1/P1 ECM connector and the connection to the user defined shutdown device (customer shutdown switch). Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Illustration 2 g01120572
P1 ECM connector
(P1-59) User defined shutdown input
Perform a 45 N (10 lb) pull test on the wire in the ECM connector that is associated with the active event code.
Check the allen head screw for each ECM connector for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and wiring for abrasion and for pinch points from the user defined shutdown device to the ECM. Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem.STOPTest Step 2. Check the Status of the User Defined Shutdown Input on Caterpillar Electronic Technician (ET)
Verify that the customer shutdown switch is in the OPEN position.
Connect Cat ET to the service tool connector.
Restore the electrical power to the ECM.
Observe the status of "User Shutdown" on Cat ET.
Switch the customer shutdown switch to the CLOSED position.
Observe the status of "User Shutdown" on Cat ET.
Remove the electrical power from the ECM. Expected Result:The status of the "User Shutdown" is "OFF" when the switch is in the OPEN position. The status of the "User Shutdown" is "ON" when the switch is in the CLOSED position.Results:
OK - The status of the "User Shutdown" is correct.Repair: There may be an intermittent problem. The problem may have been related to a faulty connection in the harness or in a connector. Carefully reinspect the connectors and wiring. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The status of the "User
Illustration 1 g01120571
Schematic
Test Step 1. Inspect Electrical Connectors and Wiring
Remove the electrical power from the ECM.
Thoroughly inspect the J1/P1 ECM connector and the connection to the user defined shutdown device (customer shutdown switch). Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Illustration 2 g01120572
P1 ECM connector
(P1-59) User defined shutdown input
Perform a 45 N (10 lb) pull test on the wire in the ECM connector that is associated with the active event code.
Check the allen head screw for each ECM connector for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and wiring for abrasion and for pinch points from the user defined shutdown device to the ECM. Expected Result:All connectors, pins, and sockets are completely inserted and coupled. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem.STOPTest Step 2. Check the Status of the User Defined Shutdown Input on Caterpillar Electronic Technician (ET)
Verify that the customer shutdown switch is in the OPEN position.
Connect Cat ET to the service tool connector.
Restore the electrical power to the ECM.
Observe the status of "User Shutdown" on Cat ET.
Switch the customer shutdown switch to the CLOSED position.
Observe the status of "User Shutdown" on Cat ET.
Remove the electrical power from the ECM. Expected Result:The status of the "User Shutdown" is "OFF" when the switch is in the OPEN position. The status of the "User Shutdown" is "ON" when the switch is in the CLOSED position.Results:
OK - The status of the "User Shutdown" is correct.Repair: There may be an intermittent problem. The problem may have been related to a faulty connection in the harness or in a connector. Carefully reinspect the connectors and wiring. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The status of the "User
Caterpillar parts catalog:
Parts hub Caterpillar catalog:
7C8369
HUB
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 214B, 224B, ...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H NA, 214B, 224B, ...
1747484
HUB AS
735, 740, D350E II, D400E II
735, 740, D350E II, D400E II
1489351
HUB
725, 725C, 730
725, 725C, 730
2584463
HUB AS
725, 725C, 730
725, 725C, 730
1542733
HUB AS
725, 730
725, 730
1905935
HUB
725, 725C, 730
725, 725C, 730
2584465
HUB AS-SPLINE
730, 730C, 735
730, 730C, 735
2584467
HUB AS
735, 735B, 740, 740B
735, 735B, 740, 740B
2994250
HUB
735, 740
735, 740
1503282
HUB
735
735
1452339
HUB AS
735, 735B, 740, 740B, 770G, 770G OEM
735, 735B, 740, 740B, 770G, 770G OEM
1394632
HUB-IMPELLER
735, 740, 770, 772, 772G, 772G OEM
735, 740, 770, 772, 772G, 772G OEM
2988704
HUB-IMPELLER
CX28
CX28
2988705
HUB-IMPELLER
CX28
CX28
2585662
HUB AS
CX28
CX28
2609536
HUB
CX31, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35, CX35-C18I, CX35-P800
CX31, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35, CX35-C18I, CX35-P800
2609530
HUB-IMPELLER
730C, 824K, 825K, 826K, 980K, 980K HLG, 980M, 982M, 986H, CX31, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35, CX35-C18I, CX35-P800, R3000H
730C, 824K, 825K, 826K, 980K, 980K HLG, 980M, 982M, 986H, CX31, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, CX35, CX35-C18I, CX35-P800, R3000H
3049034
HUB-CLUTCH
CX35, CX35-C18I, CX35-P800
CX35, CX35-C18I, CX35-P800
2431320
HUB
735, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
735, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
2750819
HUB
C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
C9, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX31-P600, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
1355561
HUB
725, 725C, 730, 735, AD30, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
725, 725C, 730, 735, AD30, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
1541205
HUB-IMPELLER
725, 725C, 730, 735, AD30, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
725, 725C, 730, 735, AD30, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
2156432
HUB AS
725, 725C, 730, 735, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
725, 725C, 730, 735, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
1401724
HUB
725, 725C, 730, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81
725, 725C, 730, C9, TH31-E61, TH35-C11I, TH35-C13I, TH35-C13T, TH35-C15I, TH35-C15T, TH35-E81