Information:
Machine ECM
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the travel alarm circuit of the machine.
Table 1
Machine ECM (MID 299)
DTC Code Description System Response
376-3 Travel Alarm : Voltage Above Normal The ECM will prevent the operator from engaging the machine in the reverse direction.
376-5 Travel Alarm : Current Below Normal The ECM will prevent the operator from engaging the machine in the reverse direction.
376-6 Travel Alarm : Current Above Normal The ECM will prevent the operator from engaging the machine in the reverse direction. Possible causes for an FMI 3 diagnostic code are:
The travel alarm is shorted to a + battery source.
The Machine ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 5 diagnostic code are:
The energize circuit of the travel alarm is open.
The return circuit of the travel alarm is open.
The travel alarm has failed.
The Machine ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 diagnostic code are:
The travel alarm circuit is shorted to ground
The travel alarm has failed.
The Machine ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03436676
Travel Alarm Circuit
Note: The diagram above is a simplified schematic of the Travel Alarm connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR2487 (374F) or Electrical Schematic, UENR2489 (390F) for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure.
Table 2
Troubleshooting Test Steps Values Results
1. Identify The Active FMI Code Associated With The Solenoid Circuit Code present FMI 3 diagnostic code, Proceed to Test Step 2.
FMI 5 diagnostic code, proceed to Test Step 3.
FMI 6 diagnostic code, proceed to Test Step 5.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Signal Circuit For A Short
A.
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the travel alarm circuit of the machine.
Table 1
Machine ECM (MID 299)
DTC Code Description System Response
376-3 Travel Alarm : Voltage Above Normal The ECM will prevent the operator from engaging the machine in the reverse direction.
376-5 Travel Alarm : Current Below Normal The ECM will prevent the operator from engaging the machine in the reverse direction.
376-6 Travel Alarm : Current Above Normal The ECM will prevent the operator from engaging the machine in the reverse direction. Possible causes for an FMI 3 diagnostic code are:
The travel alarm is shorted to a + battery source.
The Machine ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 5 diagnostic code are:
The energize circuit of the travel alarm is open.
The return circuit of the travel alarm is open.
The travel alarm has failed.
The Machine ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 diagnostic code are:
The travel alarm circuit is shorted to ground
The travel alarm has failed.
The Machine ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03436676
Travel Alarm Circuit
Note: The diagram above is a simplified schematic of the Travel Alarm connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR2487 (374F) or Electrical Schematic, UENR2489 (390F) for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure.
Table 2
Troubleshooting Test Steps Values Results
1. Identify The Active FMI Code Associated With The Solenoid Circuit Code present FMI 3 diagnostic code, Proceed to Test Step 2.
FMI 5 diagnostic code, proceed to Test Step 3.
FMI 6 diagnostic code, proceed to Test Step 5.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Signal Circuit For A Short
A.
Caterpillar parts catalog:
Parts hub Caterpillar catalog:
1353410
HUB
M318, M318C, M318C MH, M320, M322C
M318, M318C, M318C MH, M320, M322C
1308029
HUB-CLUTCH
M312, M313C, M313D, M315D 2
M312, M313C, M313D, M315D 2
1349371
HUB-COUPLING
M312, M313C
M312, M313C
2237894
HUB GP-WHEEL
M312, M313C
M312, M313C
2160088
HUB-CLUTCH
M315, M315C, M315D, M316C, M316D, M317D 2, M318, M318C, M318C MH, M318D, M318D MH, M322D MH
M315, M315C, M315D, M316C, M316D, M317D 2, M318, M318C, M318C MH, M318D, M318D MH, M322D MH
1349682
HUB
M315, M315C, M315D, M316C, M316D, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
M315, M315C, M315D, M316C, M316D, M318, M318C, M318C MH, M318D, M318D MH, M320, M322C, M322D, M322D MH
1985005
HUB
304, 304.5, 305, 305.5, 306
304, 304.5, 305, 305.5, 306
1099248
HUB
305.5, 306, 307, 307B, 307C, 307D, 308C, 308D
305.5, 306, 307, 307B, 307C, 307D, 308C, 308D
1023857
HUB
315, 315B, 317B LN
315, 315B, 317B LN
1521803
HUB
302.5, 303.5, 304.5
302.5, 303.5, 304.5
6I6426
HUB
311, 311B, 312B, 313B, 910G
311, 311B, 312B, 313B, 910G
1597179
HUB
301.5
301.5