72020016 HUB, FLANGE Caterpillar parts
CS-433
Rating:
Alternative (cross code) number:
CA72020016
7202-0016
72020016
CA72020016
7202-0016
72020016
VIBRATORY COMPACTOR,
Compatible equipment models: 72020016:
Information:
Load Sensing During the Slight Operation of an Individual Cylinder
Illustration 2 g00875502
Bucket control valve (BUCKET CLOSE) (1) Bucket cylinder (9) Flow compensator valve (10) Valve chamber (15) Passage (16) Passage (30) Passage (31) Passage (32) Spool (PD) Delivery pressure (PL) Load pressure (LS) Load sensing signal pressureCombined flow from the front pump and rear pump (PD) enters the bucket control valve. Spool (32) moves a slight amount to the left. Passage (31) opens a slight amount. The oil delivery flows through passage (31), valve chamber (10), passage (30) and passage (16). The oil then flows to bucket cylinder (1). The true load signal pressure (PL) is generated in passages (16) and (15). True load signal pressure (PL) flows to the signal duplication valve. The true load signal pressure is duplicated as load sensing signal pressure. The load sensing signal pressure is sent to the flow compensator valves. The load signal pressure flows to the front pump and the rear pump in order to regulate the output flow of the pumps.The output flow of the pumps is decreased in order to maintain a pressure difference between the pump delivery pressure (PD) and the load sensing signal pressure (LS) to 1960 kPa (285 psi). If the bucket control lever is moved closer to the NEUTRAL position, the size of the opening at passage (31) decreases.As the pump oil flow through passage (31) decreases, pressure in the passage that is below flow compensator valve (9) decreases. Load signal pressure (PL) in passage (16), the load sensing signal pressure (LS) and the force of the spring on the flow compensator valve (9) pushes flow compensator valve (9) downward. This reduces the flow through passage (30) which results in a pressure decrease in passages (16) and (15). The reduced load signal pressure in passage (15) flows to the signal duplication valve and the load sensing signal pressure is also reduced. The output flow of the pumps decreases further by load sensing regulation.When the output flow of the pumps is decreased, the size of the opening at compensator valve (9) is also decreased.Load Sensing During Combined Control Valve Operations
Illustration 3 g01108697
Circuit diagram for combined control valve operation (BOOM RAISE and STICK OUT) (1) Stick cylinder (2) Boom cylinder (3) Passage (5) Shuttle valve (7) Signal duplication valve (8) Passage (9) Shuttle valve (10) Passage (12) Shuttle valve (13) Compensator valve (boom) (14) Boom control valve (16) Passage (17) Stick control valve (18) Compensator valve (stick) (22) Load check valve (23) Passage (24) Passage (25) Passage (27) Passage (28) Passage (29) Passage (30) Boom drift reduction valve (31) Pilot pump (32) Front pump (33) Rear pump (34) Orifice (40) Line (41) True load signal port (42) Duplicate load signal port (PD) Pump delivery pressure (PLS) Load pressure (stick side) (PLB) Load pressure (boom side) (LS) Load sensing signal pressureIn the following explanation of oil flow, the joysticks are at the FULL STROKE position.. The boom hydraulic circuit and the stick hydraulic circuit are operated for a combined
Illustration 2 g00875502
Bucket control valve (BUCKET CLOSE) (1) Bucket cylinder (9) Flow compensator valve (10) Valve chamber (15) Passage (16) Passage (30) Passage (31) Passage (32) Spool (PD) Delivery pressure (PL) Load pressure (LS) Load sensing signal pressureCombined flow from the front pump and rear pump (PD) enters the bucket control valve. Spool (32) moves a slight amount to the left. Passage (31) opens a slight amount. The oil delivery flows through passage (31), valve chamber (10), passage (30) and passage (16). The oil then flows to bucket cylinder (1). The true load signal pressure (PL) is generated in passages (16) and (15). True load signal pressure (PL) flows to the signal duplication valve. The true load signal pressure is duplicated as load sensing signal pressure. The load sensing signal pressure is sent to the flow compensator valves. The load signal pressure flows to the front pump and the rear pump in order to regulate the output flow of the pumps.The output flow of the pumps is decreased in order to maintain a pressure difference between the pump delivery pressure (PD) and the load sensing signal pressure (LS) to 1960 kPa (285 psi). If the bucket control lever is moved closer to the NEUTRAL position, the size of the opening at passage (31) decreases.As the pump oil flow through passage (31) decreases, pressure in the passage that is below flow compensator valve (9) decreases. Load signal pressure (PL) in passage (16), the load sensing signal pressure (LS) and the force of the spring on the flow compensator valve (9) pushes flow compensator valve (9) downward. This reduces the flow through passage (30) which results in a pressure decrease in passages (16) and (15). The reduced load signal pressure in passage (15) flows to the signal duplication valve and the load sensing signal pressure is also reduced. The output flow of the pumps decreases further by load sensing regulation.When the output flow of the pumps is decreased, the size of the opening at compensator valve (9) is also decreased.Load Sensing During Combined Control Valve Operations
Illustration 3 g01108697
Circuit diagram for combined control valve operation (BOOM RAISE and STICK OUT) (1) Stick cylinder (2) Boom cylinder (3) Passage (5) Shuttle valve (7) Signal duplication valve (8) Passage (9) Shuttle valve (10) Passage (12) Shuttle valve (13) Compensator valve (boom) (14) Boom control valve (16) Passage (17) Stick control valve (18) Compensator valve (stick) (22) Load check valve (23) Passage (24) Passage (25) Passage (27) Passage (28) Passage (29) Passage (30) Boom drift reduction valve (31) Pilot pump (32) Front pump (33) Rear pump (34) Orifice (40) Line (41) True load signal port (42) Duplicate load signal port (PD) Pump delivery pressure (PLS) Load pressure (stick side) (PLB) Load pressure (boom side) (LS) Load sensing signal pressureIn the following explanation of oil flow, the joysticks are at the FULL STROKE position.. The boom hydraulic circuit and the stick hydraulic circuit are operated for a combined
Caterpillar parts catalog:
Parts hub Caterpillar catalog:
03001503
HUB, DRIVE
CS-433
CS-433
04001357
HUB
CS-431, CS-433, TSF-54, TSM-54
CS-431, CS-433, TSF-54, TSM-54
63020008
HUB
CB-414, CB-514
CB-414, CB-514
4129
HUB R.H.
PR-105, WE-851B
PR-105, WE-851B
4128
HUB L.H.
WE-851B
WE-851B
88331
HUB
WE-851B
WE-851B
434298
HUB
PR-450
PR-450
413503002
HUB
PR-105, PR-450
PR-105, PR-450
69020651
HUB
CS-433
CS-433
69020650
HUB AND DRUM ASSY.
CS-433
CS-433