2D4257 HYDRAULIC STEERING BOOSTER GROUP Caterpillar parts
12E
Rating:
Alternative (cross code) number:
CA2D4257
2D-4257
2D4257
CA2D4257
2D-4257
2D4257
MOTOR GRADER,
Compatible equipment models: 2D4257:
Information:
Illustration 1 g01067572
Schematic for the Raise Solenoid
This diagnostic code is associated with the raise solenoid valve. The FMI 06 means that the current in the solenoid circuit is above normal. The possible causes of this diagnostic code are listed:
The solenoid winding has low impedance or the solenoid winding is shorted.
The signal circuit from the ECM for the solenoid is shorted to ground.System Response:The machine response is listed:Since hydraulic flow to the cylinder is supplied by two control valves, the raise function is disabled. The blade will be able to be lowered.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0354 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 0354 FMI 06 changes to CID 0354 FMI 05 when the solenoid is disconnected.Results:
YES - CID 0354 FMI 06 changes to CID 0354 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid.STOP
NO - CID 0354 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J1-10 (wire H713-PK(Pink)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-10 (wire H713-PK(Pink)) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0354 FMI 06. Expected Result:The CID 0354 FMI 06 is active. Results:
YES - The CID 0354 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts hydraulic Caterpillar catalog:
4D4661
HYDRAULIC PUMP ASSEMBLY
120, 120B, 12E, 140
120, 120B, 12E, 140
1470521
HYDRAULIC AR-VIBRATORY
CS-563C
CS-563C
1240399
HYDRAULIC AR-AUXILIARY
CB-434B
CB-434B
1666819
HYDRAULIC AR-PROPEL
CS-431C
CS-431C
1153102
HYDRAULIC AR
320B
320B
5G4119
HYDRAULIC AR
910, G910
910, G910