2883691 IDLER GP-TCK- Caterpillar parts
Rating:
Alternative (cross code) number:
CA2883691
288-3691
2883691
CA2883691
288-3691
2883691
Weight: 660 pounds 299 kg.
Information:
Illustration 1 g01135186
Schematic of the Bucket Cylinder Extend SolenoidThis diagnostic code is associated with the Bucket Cylinder Extend Solenoid. The FMI 06 means that the ECM has determined that there is a short to ground in the circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1141 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the solenoid with the active diagnostic code from the machine harness. Expected Result:CID 1141 FMI 06 changes to CID 1141 FMI 05 when the solenoid is disconnected.Results:
YES - CID 1141 FMI 06 changes to CID 1141 FMI 05 when the solenoid is disconnected. The circuit is correct.Repair: The solenoid has failed. Repeat this test "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Stop.
NO - CID 1141 FMI 06 remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The solenoid remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-15 (wire K931-GN) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-15 (wire K931-GN) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. Stop.Test Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1141 FMI 06. Expected Result:The CID 1141 FMI 06 is active. Results:
YES - The CID 1141 FMI 06 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
NO - The CID 1141 FMI 06 is not active. The diagnostic code does not exist at this time.
Parts idler Caterpillar catalog:
2877434
IDLER GP-
Caterpillar
Caterpillar
2877433
IDLER GP-
Caterpillar
Caterpillar
2869830
IDLER GP-CLA
Caterpillar
Caterpillar
2868314
IDLER GP-
Caterpillar
Caterpillar
2868313
IDLER GP-
Caterpillar
Caterpillar
2864234
IDLER GP-RH
Caterpillar
Caterpillar
2960068
IDLER AR-HDWR
Caterpillar
Caterpillar
2945070
IDLER GP-TRACK
Caterpillar
Caterpillar
2928076
IDLER GP -
Caterpillar
Caterpillar
2921149
IDLER AS
Caterpillar
Caterpillar
2900751
IDLER
Caterpillar
Caterpillar
2893135
IDLER AS-LH
Caterpillar
Caterpillar