2979259 IDLER GP-FRONT Caterpillar parts
349E, 349E L, 349E L VG
Rating:
Alternative (cross code) number:
CA2979259
297-9259
2979259
CA2979259
297-9259
2979259
EXCAVATOR,
Information:
Min/Max Function Key
Minimum and maximum readings are recorded using MIN/MAX key (6). To use this function, continue as follows.
Apply pressure to the system.
Press MIN/MAX key (6). The MIN/MAX icon will illuminate at the top right of the LCD display, indicating the readings are being recorded.
To display minimum readings, press the MIN/MAX key again. The MIN icon will be illuminated and only the minimum readings will be displayed.
To display maximum readings, press the MIN/MAX key again. The MAX icon will be illuminated and only maximum readings will be displayed.
To scroll between the minimum and maximum readings, continue to press the MIN/MAX key.
To exit this function, press and hold the MIN/MAX key for 2 seconds. This turns off the MIN/MAX icon and returns the display to real-time (live) readings.Delta Zero Function Key
A temporary zero may be set to monitor pressure drops or rises using this function. To monitor a pressure drop or rise, continue as follows.
Stabilize the system pressure.
Press DELTA ZERO key (7). The LCD will now display "0 PSI".
Any decrease in pressure will be displayed as negative pressure, increases will be displayed as positive pressure.
Press the DELTA ZERO key again to exit the function.Sensor Zero Function Key
Note: Pressure pickup sensors are temperature sensitive. Whenever possible, the pressure pickup sensor should be allowed to warm up to the system temperature. Install the pressure pickup sensor(s) into the test port(s) of the machine approximately 5 minutes prior to running a test. Zero the sensor(s) before starting the test.This function key sets a true zero point prior to testing. Each pressure pickup sensor must be zeroed prior to a test to ensure accuracy. To zero a pressure pickup sensor, continue as follows.
Turn range select switch (10) to the appropriate pressure range setting. The "Sensor 1" icon should be illuminated at the top of the LCD display. If another sensor is shown, press SENSOR SELECT key (9) until the "Sensor 1" icon is displayed.
Press SENSOR ZERO key (8) to zero sensor 1.
If multiple pressure pickup sensors are used, select the next sensor by pressing the sensor select key.
When the desired pressure pickup sensor icon is illuminated, press the SENSOR ZERO key to zero the sensor.
After all the pressure pickup sensors are zeroed, pressure may be applied to the sensor and the pressure reading will be displayed on the LCD.Sensor Select Function Key
To select a pressure pickup sensor, continue as follows.
Press SENSOR SELECT key (9) and toggle between sensor connectors 1, 2, 3, and 4.
When selecting functions, press the related key for one second. This timing feature guards against misreading function changes caused by accidentally pressing a key.Range Select Switch
The range select switch (10) selects the pressure range and provides a color code for the pressure pickup sensor being used (blue, red, or orange). Readout units on the indicator are in PSI or BAR ( BAR x 100 = kPa). The range select switch is also used to select temperature in degrees C or F.When changing ranges, turn the range select switch to the
Minimum and maximum readings are recorded using MIN/MAX key (6). To use this function, continue as follows.
Apply pressure to the system.
Press MIN/MAX key (6). The MIN/MAX icon will illuminate at the top right of the LCD display, indicating the readings are being recorded.
To display minimum readings, press the MIN/MAX key again. The MIN icon will be illuminated and only the minimum readings will be displayed.
To display maximum readings, press the MIN/MAX key again. The MAX icon will be illuminated and only maximum readings will be displayed.
To scroll between the minimum and maximum readings, continue to press the MIN/MAX key.
To exit this function, press and hold the MIN/MAX key for 2 seconds. This turns off the MIN/MAX icon and returns the display to real-time (live) readings.Delta Zero Function Key
A temporary zero may be set to monitor pressure drops or rises using this function. To monitor a pressure drop or rise, continue as follows.
Stabilize the system pressure.
Press DELTA ZERO key (7). The LCD will now display "0 PSI".
Any decrease in pressure will be displayed as negative pressure, increases will be displayed as positive pressure.
Press the DELTA ZERO key again to exit the function.Sensor Zero Function Key
Note: Pressure pickup sensors are temperature sensitive. Whenever possible, the pressure pickup sensor should be allowed to warm up to the system temperature. Install the pressure pickup sensor(s) into the test port(s) of the machine approximately 5 minutes prior to running a test. Zero the sensor(s) before starting the test.This function key sets a true zero point prior to testing. Each pressure pickup sensor must be zeroed prior to a test to ensure accuracy. To zero a pressure pickup sensor, continue as follows.
Turn range select switch (10) to the appropriate pressure range setting. The "Sensor 1" icon should be illuminated at the top of the LCD display. If another sensor is shown, press SENSOR SELECT key (9) until the "Sensor 1" icon is displayed.
Press SENSOR ZERO key (8) to zero sensor 1.
If multiple pressure pickup sensors are used, select the next sensor by pressing the sensor select key.
When the desired pressure pickup sensor icon is illuminated, press the SENSOR ZERO key to zero the sensor.
After all the pressure pickup sensors are zeroed, pressure may be applied to the sensor and the pressure reading will be displayed on the LCD.Sensor Select Function Key
To select a pressure pickup sensor, continue as follows.
Press SENSOR SELECT key (9) and toggle between sensor connectors 1, 2, 3, and 4.
When selecting functions, press the related key for one second. This timing feature guards against misreading function changes caused by accidentally pressing a key.Range Select Switch
The range select switch (10) selects the pressure range and provides a color code for the pressure pickup sensor being used (blue, red, or orange). Readout units on the indicator are in PSI or BAR ( BAR x 100 = kPa). The range select switch is also used to select temperature in degrees C or F.When changing ranges, turn the range select switch to the
Caterpillar SIS machinery equipment:
Caterpillar SIS
349E L Excavators KFX00001-UP (MACHINE) POWERED BY C13 Engine »
297-9259
IDLER GP-FRONT
349E L Excavators MPZ00001-UP (MACHINE) POWERED BY C13 Engine »
297-9259
IDLER GP-FRONT
349E L-VG Excavators DGE00001-UP (MACHINE) POWERED BY C13 Engine »
297-9259
IDLER GP-FRONT
349E & 349E L Excavators FJB00001-UP (MACHINE) POWERED BY C13 Engine »
297-9259
IDLER GP-FRONT
Caterpillar parts catalog:
Parts idler Caterpillar catalog:
1941170
IDLER GP-FRONT
330C, 330C L
330C, 330C L
2766169
IDLER GP-FRONT
323D LN
323D LN
3295409
IDLER GP-TRACK
D8R, D8T
D8R, D8T
7Y1612
IDLER GP-FRONT
320 L, 325, 325 L, 325 LN, OEMS
320 L, 325, 325 L, 325 LN, OEMS
1079358
IDLER GP-TRACK
D8R, D8R II
D8R, D8R II
2T0046
IDLER GP
615, 615C, 623E, 623F, 623G
615, 615C, 623E, 623F, 623G
2487215
IDLER GP-FRONT
320D, 320D FM, 320D FM RR
320D, 320D FM, 320D FM RR
2459947
IDLER GP-TRACK
D10R, D10T, D10T2
D10R, D10T, D10T2
1920220
IDLER GP-TRACK
572R II, D7R, D7R II, D7R XR
572R II, D7R, D7R II, D7R XR
2979237
IDLER GP-FRONT
349E, 349E L, 349E L HVG, 349E L VG
349E, 349E L, 349E L HVG, 349E L VG