1T0709 IMPELLER Caterpillar parts
627, 627B, 637, 977K, 977L, 980, 980B
Rating:
Alternative (cross code) number:
CA1T0709
1T-0709
1T0709
CA1T0709
1T-0709
1T0709
Weight: 15 pounds 6 kg.
TRACK LOADER, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$264.59
16 Aug 2023
US: Florida-Parts-Z
1T0709 - Impeller-Converter fit Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 1T0709:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Low Voltage Insulation Testing Gp 1
349-4206 High Voltage Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester Black lead to ground.
Connect the insulation tester RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 1 min/10 min Time Resistance Method:
Apply voltage.
Observe the readings at 1 minute intervals. Observe the readings at 10 minute
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Low Voltage Insulation Testing Gp 1
349-4206 High Voltage Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator main stator winding. The frequency of this test is determined by the generator environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester Black lead to ground.
Connect the insulation tester RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 1 min/10 min Time Resistance Method:
Apply voltage.
Observe the readings at 1 minute intervals. Observe the readings at 10 minute
Caterpillar parts catalog:
Parts impeller Caterpillar catalog:
1299907
IMPELLER-PUMP
16G, 16H NA, 24M, 3406, 3406B, 3406C, 3406E, 3456, 375, 375 L, 385B, 5080, 5090B, 578, 583R, 583T, 587R, 587T, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627B, 627F, 627G, 631D, 631E, 631G, 633E II, 63...
16G, 16H NA, 24M, 3406, 3406B, 3406C, 3406E, 3456, 375, 375 L, 385B, 5080, 5090B, 578, 583R, 583T, 587R, 587T, 621B, 621E, 621F, 621G, 623E, 623F, 623G, 627B, 627F, 627G, 631D, 631E, 631G, 633E II, 63...
6N8411
IMPELLER
120G, 140B, 1673C, 215, 3304, 3306, 920, 930, 941, 950, 977K, D4D, D5, D6C, G3304, G3306
120G, 140B, 1673C, 215, 3304, 3306, 920, 930, 941, 950, 977K, D4D, D5, D6C, G3304, G3306
9S1296
IMPELLER
1676, 621, 980
1676, 621, 980
8S9273
IMPELLER ASSEM.
966C, 977K, D6C
966C, 977K, D6C
8M6561
IMPELLER
16, 594, 631C, 657, 666, 769, 824, 824B, 825B, 834, 977H, 977K, 983, 988, D9G, D9H
16, 594, 631C, 657, 666, 769, 824, 824B, 825B, 834, 977H, 977K, 983, 988, D9G, D9H
2S4437
IMPELLER ASSEM.
621, 980
621, 980
1T0821
IMPELLER
980
980
8M6561
IMPELLER
16, 594, 631C, 657, 666, 769, 824, 824B, 825B, 834, 977H, 977K, 983, 988, D9G, D9H
16, 594, 631C, 657, 666, 769, 824, 824B, 825B, 834, 977H, 977K, 983, 988, D9G, D9H
8S9273
IMPELLER ASSEM.
966C, 977K, D6C
966C, 977K, D6C
3716782
IMPELLER-PUMP
374F L, 390F L, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, 834K, 836K, 988K, D9T
374F L, 390F L, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, 834K, 836K, 988K, D9T
1T2089
IMPELLER
D6R, D6R STD
D6R, D6R STD
2060492
IMPELLER-CONVERTER
583T, D8T, PL83
583T, D8T, PL83
6N6423
IMPELLER
D9H
D9H
1T0861
IMPELLER
621, 621B, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637G, 983, 983B, R1700 II, R1700G
621, 621B, 621E, 621F, 621G, 621H, 621K, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627E, 627F, 627G, 627H, 627K, 627K LRC, 637G, 983, 983B, R1700 II, R1700G
1T0633
IMPELLER
D8K
D8K
4M2346
IMPELLER ASSEM.
12E, 561B, 977H
12E, 561B, 977H
1T0724
IMPELLER
955K, 955L
955K, 955L
9S8041
IMPELLER
14E, 941, 966C, D6C, D7F
14E, 941, 966C, D6C, D7F