3519431 INHIBITOR- Caterpillar parts
Rating:
Alternative (cross code) number:
CA3519431
351-9431
3519431
CA3519431
351-9431
3519431
Weight: 8 pounds 3 kg.
Information:
Test for the Line Relief Valve on the Auxiliary Control Valve
Note: A temporary setting of the main relief valve pressure is required before any line relief valve pressure setting is adjusted. Refer to the temporary setting of the main relief valve in Testing and Adjusting, "Relief Valve (Main) - Test and Adjust" for the machine.
Illustration 1 g03629837
(1) Up key
(2) Cancel key
(3) OK key
(4) Enter key
(5) Right key
(6) Down key
(7) Left key
(8) Main menu key
Position the machine on level ground and stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release" for the machine.
Illustration 2 g01534994
Pump Compartment
(9) Pressure tap (drive pump )
(10) Pressure tap (idler pump )
(11) Pressure tap (power shift)
Install a pressure gauge with a 6000 kPa (870 psi) capacity on pressure tap (11) for the power shift.
Install a pressure gauge with a 60000 kPa (8700 psi) capacity on pressure tap (9) for the drive pump.
Start the engine.
Place the machine controls at the following settings: engine speed dial 10 and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for the machine for engine rpm settings.
Warm the hydraulic oil to 50 °C (122 °F).
Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.
Use the following procedure to access the "Service" mode of the monitor.
From the default screen, press the main menu key (8).
Use the right key (5) or the left key (7) in order to scroll through the menu options.
When the "Service" option is highlighted, press the OK key (3). Note: In order to access the "Service" screen, the password for service must be entered.
When "Password" screen appears, use the right key (5) and the left key (7) in order to scroll through the characters. When the desired character is highlighted, press the OK key (3). Enter the password for service 9992 in order to continue to the "Service" screen.
After the password has been entered the "Service" screen should appear. Refer to Illustration. Note: For more detailed steps with entering passwords or entering the service mode, refer to Testing and Adjusting, "Service Mode - Enter" for the machine.
Use the down key (6) in order to scroll through the menu options.
When the "Override Parameters" option is highlighted, press the OK key (3).
After the OK key is pressed, the "Override Parameters" menu should appear.
Use the down key (6) in order to scroll through the menu options.
When the "Power Shift Pressure" option is highlighted, press the OK key (3).
Illustration 3 g02319174
Use the down key (6) in order to highlight the value of the power shift pressure.
Use the right key (5) in order to decrease the value of the power shift pressure. Use the left key (7) in order to increase the value of the power shift pressure. Pressing the left key (7) one time decreases the power shift pressure 10 kPa (1.5 psi). Pressing the right key (5) one time increases the power shift pressure 10 kPa (1.5
Note: A temporary setting of the main relief valve pressure is required before any line relief valve pressure setting is adjusted. Refer to the temporary setting of the main relief valve in Testing and Adjusting, "Relief Valve (Main) - Test and Adjust" for the machine.
Illustration 1 g03629837
(1) Up key
(2) Cancel key
(3) OK key
(4) Enter key
(5) Right key
(6) Down key
(7) Left key
(8) Main menu key
Position the machine on level ground and stop the engine.
Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic System Pressure - Release" for the machine.
Illustration 2 g01534994
Pump Compartment
(9) Pressure tap (drive pump )
(10) Pressure tap (idler pump )
(11) Pressure tap (power shift)
Install a pressure gauge with a 6000 kPa (870 psi) capacity on pressure tap (11) for the power shift.
Install a pressure gauge with a 60000 kPa (8700 psi) capacity on pressure tap (9) for the drive pump.
Start the engine.
Place the machine controls at the following settings: engine speed dial 10 and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for the machine for engine rpm settings.
Warm the hydraulic oil to 50 °C (122 °F).
Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.
Use the following procedure to access the "Service" mode of the monitor.
From the default screen, press the main menu key (8).
Use the right key (5) or the left key (7) in order to scroll through the menu options.
When the "Service" option is highlighted, press the OK key (3). Note: In order to access the "Service" screen, the password for service must be entered.
When "Password" screen appears, use the right key (5) and the left key (7) in order to scroll through the characters. When the desired character is highlighted, press the OK key (3). Enter the password for service 9992 in order to continue to the "Service" screen.
After the password has been entered the "Service" screen should appear. Refer to Illustration. Note: For more detailed steps with entering passwords or entering the service mode, refer to Testing and Adjusting, "Service Mode - Enter" for the machine.
Use the down key (6) in order to scroll through the menu options.
When the "Override Parameters" option is highlighted, press the OK key (3).
After the OK key is pressed, the "Override Parameters" menu should appear.
Use the down key (6) in order to scroll through the menu options.
When the "Power Shift Pressure" option is highlighted, press the OK key (3).
Illustration 3 g02319174
Use the down key (6) in order to highlight the value of the power shift pressure.
Use the right key (5) in order to decrease the value of the power shift pressure. Use the left key (7) in order to increase the value of the power shift pressure. Pressing the left key (7) one time decreases the power shift pressure 10 kPa (1.5 psi). Pressing the right key (5) one time increases the power shift pressure 10 kPa (1.5
Parts inhibitor Caterpillar catalog:
2Y2523
INHIBITOR
Caterpillar
Caterpillar
0P0002
INHIBITOR PACK
Caterpillar
Caterpillar
0P0001
INHIBITOR PACK
Caterpillar
Caterpillar
0063868
INHIBITOR
Caterpillar
Caterpillar
4231905
INHIBITOR
3512C
3512C
3872877
INHIBITOR-
Caterpillar
Caterpillar
3758010
INHIBITOR-
Caterpillar
Caterpillar
3758009
INHIBITOR-
Caterpillar
Caterpillar
3662753
INHIBITOR-
Caterpillar
Caterpillar
3519433
INHIBITOR-
Caterpillar
Caterpillar
3519432
INHIBITOR-
Caterpillar
Caterpillar