Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
The block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load
The amount of load If derating is required in order to block load, refer to ISO 3046 or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices. This current is called the reactive load. This current does not require engine power to be maintained.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a power factor of 0.8 or less. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor goes up, the total current that is supplied to a constant power demand will go down. A 100 kW load that is at 0.8 power factor will draw more current than a 100 kW load that is at 0.9 power factor. A high power factor will result in a full engine load at less than the generator rated amperage. A lower power factor increases the possibility of overloading the generator.Note: The Caterpillar generators are rated at a power factor of 0.8 unless the generator is specified otherwise. Excitation System
The generator uses the AREP excitation system. This system does not use a permanent magnet. The voltage regulator is powered by two auxiliary windings. These windings are independent of the circuit for detecting voltage. The first winding is labelled as "X1" and "X2". This winding has a voltage that
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. An electrical unbalance can result in an electrical overload and overheating if one phase current exceeds the nameplate amperage.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
The block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load
The amount of load If derating is required in order to block load, refer to ISO 3046 or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices. This current is called the reactive load. This current does not require engine power to be maintained.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a power factor of 0.8 or less. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor goes up, the total current that is supplied to a constant power demand will go down. A 100 kW load that is at 0.8 power factor will draw more current than a 100 kW load that is at 0.9 power factor. A high power factor will result in a full engine load at less than the generator rated amperage. A lower power factor increases the possibility of overloading the generator.Note: The Caterpillar generators are rated at a power factor of 0.8 unless the generator is specified otherwise. Excitation System
The generator uses the AREP excitation system. This system does not use a permanent magnet. The voltage regulator is powered by two auxiliary windings. These windings are independent of the circuit for detecting voltage. The first winding is labelled as "X1" and "X2". This winding has a voltage that
Caterpillar parts catalog:
Parts insulation Caterpillar catalog:
3860680
INSULATION
302.7D
302.7D
3860686
INSULATION
302.7D
302.7D
3860703
INSULATION
302.7D
302.7D
4435007
INSULATION
302.7D
302.7D
3860692
INSULATION
302.7D
302.7D
3860812
INSULATION
302.7D
302.7D
3860809
INSULATION
302.7D
302.7D
3860724
INSULATION
302.7D
302.7D
3860826
INSULATION
302.7D
302.7D
4435006
INSULATION
302.7D
302.7D
3842435
INSULATION
302.7D
302.7D
3860680
INSULATION
302.7D
302.7D
3792828
INSULATION
301.4C
301.4C
3792763
INSULATION
301.4C
301.4C
3792759
INSULATION
301.4C
301.4C
4435007
INSULATION
302.7D
302.7D
3860703
INSULATION
302.7D
302.7D
3860686
INSULATION
302.7D
302.7D
3860687
INSULATION
302.7D
302.7D
3860685
INSULATION
302.7D
302.7D
3860704
INSULATION
302.7D
302.7D